scholarly journals Surface Modification of Titanium Dental Implants: A Review

2018 ◽  
Vol 1 (1) ◽  
pp. 38-46
Author(s):  
Ujjwal Rimal ◽  
S. Joshi ◽  
P. Shrestha

Osseointegration of titanium dental implants is the most important clinical parameter for an implant to be successful. One of most biocompatible material, titanium can be made to affix fast on to host bone via various modification of its surface. Machined and smooth titanium implant osseointegrate into living bone tissue but with a roughened surface, this is much more predictable as well as promising clinically. Surface modification allows for an increase in the surface area on to which the osteoblasts easily start laying bone. So, there have been various methods to roughen the surface of titanium implants. The article describes various methods used for modifying the surfaces of dental implants, giving a note on their clinical efficacy as well as advantages and disadvantages of these methods.

2007 ◽  
Vol 361-363 ◽  
pp. 613-616
Author(s):  
Laurent Le Guenhennec ◽  
Eric Goyenvalle ◽  
Marco A. Lopez-Heredia ◽  
Pierre Weiss ◽  
Yves Amouriq ◽  
...  

Titanium dental implants presenting different blasted surfaces and an OCP coated surfaces have been implanted in the femoral epiphysis of rabbits. A comparable osseointegration has been observed for the titanium implants blasted either with alumina or biphasic calcium phosphates particles whatever the delay of implantation (2 or 8 weeks). A higher bone to implant contact has been observed for the SLA and OCP coated implants as compared to the grit-blasted groups.


Nanomaterials ◽  
2021 ◽  
Vol 11 (9) ◽  
pp. 2336
Author(s):  
Sepanta Hosseinpour ◽  
Ashwin Nanda ◽  
Laurence J. Walsh ◽  
Chun Xu

Peri-implantitis is the major cause of the failure of dental implants. Since dental implants have become one of the main therapies for teeth loss, the number of patients with peri-implant diseases has been rising. Like the periodontal diseases that affect the supporting tissues of the teeth, peri-implant diseases are also associated with the formation of dental plaque biofilm, and resulting inflammation and destruction of the gingival tissues and bone. Treatments for peri-implantitis are focused on reducing the bacterial load in the pocket around the implant, and in decontaminating surfaces once bacteria have been detached. Recently, nanoengineered titanium dental implants have been introduced to improve osteointegration and provide an osteoconductive surface; however, the increased surface roughness raises issues of biofilm formation and more challenging decontamination of the implant surface. This paper reviews treatment modalities that are carried out to eliminate bacterial biofilms and slow their regrowth in terms of their advantages and disadvantages when used on titanium dental implant surfaces with nanoscale features. Such decontamination methods include physical debridement, chemo-mechanical treatments, laser ablation and photodynamic therapy, and electrochemical processes. There is a consensus that the efficient removal of the biofilm supplemented by chemical debridement and full access to the pocket is essential for treating peri-implantitis in clinical settings. Moreover, there is the potential to create ideal nano-modified titanium implants which exert antimicrobial actions and inhibit biofilm formation. Methods to achieve this include structural and surface changes via chemical and physical processes that alter the surface morphology and confer antibacterial properties. These have shown promise in preclinical investigations.


2005 ◽  
Vol 24 (4) ◽  
pp. 536-540 ◽  
Author(s):  
Yasuhiko ABE ◽  
Kyou HIASA ◽  
Maho TAKEUCHI ◽  
Yasuhiro YOSHIDA ◽  
Kazuomi SUZUKI ◽  
...  

2019 ◽  
Vol 8 (11) ◽  
pp. 1982 ◽  
Author(s):  
Asensio ◽  
Vázquez-Lasa ◽  
Rojo

Titanium and its alloys constitute the gold standard materials for oral implantology in which their performance is mainly conditioned by their osseointegration capacity in the host’s bone. We aim to provide an overview of the advances in surface modification of commercial dental implants analyzing and comparing the osseointegration capacity and the clinical outcome exhibited by different surfaces. Besides, the development of peri-implantitis constitutes one of the most common causes of implant loss due to bacteria colonization. Thus, a synergic response from industry and materials scientists is needed to provide reliable technical and commercial solutions to this issue. The second part of the review focuses on an update of the recent findings toward the development of new materials with osteogenic and antibacterial capacity that are most likely to be marketed, and their correlation with implant geometry, biomechanical behavior, biomaterials features, and clinical outcomes.


Nanoscale ◽  
2015 ◽  
Vol 7 (21) ◽  
pp. 9908-9918 ◽  
Author(s):  
Elisabeth Rieger ◽  
Agnès Dupret-Bories ◽  
Laetitia Salou ◽  
Marie-Helene Metz-Boutigue ◽  
Pierre Layrolle ◽  
...  

Nanoscale surface modification of titanium microbeads can control the soft tissue response in vitro and in vivo.


2014 ◽  
Vol 2014 ◽  
pp. 1-11 ◽  
Author(s):  
F. Mangano ◽  
L. Chambrone ◽  
R. van Noort ◽  
C. Miller ◽  
P. Hatton ◽  
...  

Statement of Problem. Direct metal laser sintering (DMLS) is a technology that allows fabrication of complex-shaped objects from powder-based materials, according to a three-dimensional (3D) computer model. With DMLS, it is possible to fabricate titanium dental implants with an inherently porous surface, a key property required of implantation devices.Objective. The aim of this review was to evaluate the evidence for the reliability of DMLS titanium dental implants and their clinical and histologic/histomorphometric outcomes, as well as their mechanical properties.Materials and Methods. Electronic database searches were performed. Inclusion criteria were clinical and radiographic studies, histologic/histomorphometric studies in humans and animals, mechanical evaluations, andin vitrocell culture studies on DMLS titanium implants. Meta-analysis could be performed only for randomized controlled trials (RCTs); to evaluate the methodological quality of observational human studies, the Newcastle-Ottawa scale (NOS) was used.Results. Twenty-seven studies were included in this review. No RCTs were found, and meta-analysis could not be performed. The outcomes of observational human studies were assessed using the NOS: these studies showed medium methodological quality.Conclusions. Several studies have demonstrated the potential for the use of DMLS titanium implants. However, further studies that demonstrate the benefits of DMLS implants over conventional implants are needed.


Sign in / Sign up

Export Citation Format

Share Document