scholarly journals The Effect of Three Polishing Systems on the Surface Rugosity of One Composite Resin

Author(s):  
Lara Pepita de Souza Oliveira ◽  
Lara Pepita de Souza Oliveira ◽  
Moises Aleli Gomes ◽  
Jefter Haad Ruiz da Silva ◽  
Cláudia Cândida Silva ◽  
...  

Direct restorations in composite resin require superficial rugosity appropriate to guarantee a surface free of biofilm buildup, which interferes with the durability of the restoration, its properties and the aesthetic aspect. Thus, it is relevant to know the behaviour of the finishing and polishing systems. The in vitro study aimed to compare the polishing efficiency of three different polishing systems in promoting the surface smoothness of a nanocomposite resin. Sixty specimens of the nanocomposite resin Filtek Z350 XT (3M) were made, randomly divided into three groups (n=20), according to the tested polishing systems: Enhance (Dentsply), DFL Polishers, and Sof-Lex Spiral (3M). The surface rugosity of the samples was measured by means of the rugosimeter equipment. The data were analysed through statistical tests: ANOVA two-way and post-hoc Tukey. The results indicated Sof-Lex (3M) polishing discs as the ones with the lowest average surface rugosity (0.13µm), presenting statistically significant results (p<0.05); followed by the abrasive rubbers of the DFL system (0.17 µm) and the Enhance system (Dentsply), which showed greater average surface rugosity (0.30 µm). The lowest surface rugosity of the composite resin evaluated in this study (Z350 XT- 3M) was obtained after polishing with the multi-step system (Sof-Lex), from the same manufacturer.

2020 ◽  
Vol 32 (4) ◽  
pp. 1-4
Author(s):  
Abeer B Mahmood

Background: Aesthetic archwires are used to overcome the aesthetic problems of stainless steel wires but the color of the coating layer can be changed with time when exposed to oral environments. The aim of this study was to evaluate the degree of color change of different aesthetic archwires from different companies under different coloring solutions. Materials and Methods: One hundred fifty samples of coated archwires from three companies (Highland, G&H and Dany) were immersed in 5 solutions (artificial saliva, turmeric, tea, coffee and Miranda) to evaluate the degree of color changes after 7, 14 and 21 days using visible spectrophotometer. Data were collected and analyzed using one way ANOVA and post hoc Tukey’s tests. Results: Turmeric solution caused high color change than other solutions. Aesthetic archwires from Highland company showed the highest degree of color change than archwires from other companies. Conclusions: Turmeric solution produced more discoloration than other solutions and the effects of these solutions are related to different chemical compositions of those solutions.


2018 ◽  
Vol 19 (2) ◽  
pp. 130-136 ◽  
Author(s):  
HP Vivek ◽  
Seema Geetha ◽  
Sabari Chandramohan ◽  
Md Imranulla ◽  
PB Srinidhi

ABSTRACT Aim The aim of the study was to evaluate the effect of mouthrinses containing olive oil, fluoride, and their combination on enamel erosion. Materials and methods An in vitro study of 45 enamel specimens, which were prepared from 45 extracted teeth, was employed. Each specimen was subjected to 10 alternative demineralization and remineralization cycles. Remineralizing cycle includes 5 minutes exposure with one of the mouthrinse, and demineralizing cycle includes 3 minute exposure to 1% citric acid. Mean surface roughness (Ra) was measured from surfometry before and after cycles. Statistical tests used were Student's unpaired t-test and one-way analysis of variance (ANOVA), followed by Tukey's post hoc test. Results Among the three mouthrinses, Listerine and Xerostom showed maximum protection against erosion on enamel. The 2% olive oil mouthrinse showed the least protection against erosion on enamel. Conclusion The study indicated that the Listerine and Xerostom mouthrinses are valuable preventive measures. Clinical significance Mouthrinses are effective for lessening erosive demineralization and in aggregating remineralization of tooth surfaces which are the important factors to prevent enamel erosion. How to cite this article Vivek HP, Prashant GM, Geetha S, Chandramohan S, Imranulla M, Srinidhi PB. Effect of Mouthrinses containing Olive Oil, Fluoride, and Their Combination on Enamel Erosion: An in vitro Study. J Contemp Dent Pract 2018;19(2):130-136.


Author(s):  
Nurcan Ozakar Ilday ◽  
Ozcan Karatas ◽  
Latife Altınok Uygun ◽  
Pınar Gul

Objective: The objective of this in vitro study is to examine the effect of antioxidants on the bonding strength of composite resin to bleached enamel. Materials and Methods: One hundred twenty non decay teeth were used in this study. Specimens were cut from the enamel cement junction. Then the specimens were randomly assigned into two groups-office bleaching and home bleaching. Bleaching antioxidants were applied to the first 12 subgroups. The specimens in the remaining 12 groups were kept in artificial saliva for 14 days and antioxidants were applied. Composite resin restoration was applied to all specimens. A cutting device was employed to obtain six specimens (0.9mm) from each tooth, and the microtensile bond strength (μTBS) test was performed. Data were analyzed using one-way ANOVA, the paired t-test, and Duncan’s post hoc test (p=0.05). Results: In office bleaching specimens, immediate antioxidant application increased the μTBS values (p<0.05). Comparisons of the antioxidants individually revealed that bonding values increased after two weeks in specimens subjected to antioxidant application (p<0.05). In office bleaching specimens, immediate antioxidant application increased the μTBS values (p>0.05). Mean μTBS values in the groups to which antioxidants were applied two weeks after home bleaching were higher than those in the groups in which antioxidants were applied immediately. Conclusion: The use of antioxidants after bleaching may increase the MTBS value.  The clinician should take this into account especially in immediate restoration applications after bleaching.


2016 ◽  
Vol 41 (1) ◽  
pp. 4-11
Author(s):  
Soliman Eman M ◽  
Elgayar Ibrahim L ◽  
Kamar A Adel A

Author(s):  
Ralf Krug ◽  
C. Ortmann ◽  
S. Reich ◽  
B. Hahn ◽  
G. Krastl ◽  
...  

Abstract Objectives To assess tooth discoloration induced by different hydraulic calcium silicate-based cements (HCSCs), including effects of blood and placement method. Materials and methods Eighty bovine teeth cut to a length of 18 mm (crown 8 mm, root 10 mm) were randomly assigned to 10 groups (n = 8), receiving orthograde apical plug treatment (APT). Apical plugs were 4 mm in length and made of ProRoot MTA (Dentsply), Medcem MTA (Medcem), TotalFill BC RRM Fast Set Putty (Brasseler), or Medcem Medical Portland Cement (Medcem) plus bismuth oxide (Bi2O3) with and without bovine blood. Further, orthograde (with or without preoperative adhesive coronal dentin sealing) and retrograde APT were compared. Teeth were obturated with gutta-percha and sealer, sealed with composite and stored in distilled water. Tooth color was measured on apical plug, gutta-percha/sealer, and crown surface before treatment versus 24 h, 1, 3, 6, 12, and 24 months after treatment by spectrophotometry. Color difference (ΔE) values were calculated and analyzed by Shapiro–Wilk test, ANOVA with post hoc tests, Friedman test, t test, and post hoc tests with Bonferroni correction (α = .05). Results Tooth discoloration occurred in all groups with no significant differences between HCSCs (p > .05). After 24 months, color changes were prominent on roots but insignificant on crowns. Blood contamination induced a significantly decreased luminescence (p < .05). Blood had a stronger impact on tooth color than Bi2O3. No relevant effects of retrograde placement (p > .05) or preoperative dentin sealing (p > .05) were detected. Conclusions Apical plugs of the tested HCSCs cause discoloration of bovine roots, but not discoloration of bovine tooth crowns within a 24-month period. Clinical relevance APT should be performed carefully while avoiding direct contact with the coronal dentin, and in that case no aesthetic impairments occur.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Philipp Körner ◽  
Luca Georgis ◽  
Daniel B. Wiedemeier ◽  
Thomas Attin ◽  
Florian J. Wegehaupt

Abstract Background This in-vitro-study aimed to evaluate the potential of different fluoride gels to prevent gastroesophageal reflux induced erosive tooth wear. Methods Surface baseline profiles of a total of 50 bovine enamel specimens [randomly assigned to five groups (G1–5)] were recorded. All specimens were positioned in a custom made artificial oral cavity and perfused with artificial saliva (0.5 ml/min). Reflux was simulated 11 times a day during 12 h by adding HCl (pH 3.0) for 30 s (flow rate 2 ml/min). During the remaining 12 h (overnight), specimens were stored in artificial saliva and brushed twice a day (morning and evening) with a toothbrush and toothpaste slurry (15 brushing strokes). While specimens in the control group (G1) did not receive any further treatment, specimens in G2–5 were coated with different fluoride gels [Elmex Gelée (G2); Paro Amin Fluor Gelée (G3); Paro Fluor Gelée Natriumfluorid (G4); Sensodyne ProSchmelz Fluorid Gelée (G5)] in the evening for 30 s. After 20 days, surface profiles were recorded again and enamel loss was determined by comparing them with the baseline profiles. The results were statistically analysed using one-way analysis of variance (ANOVA) followed by Tukey`s HSD post-hoc test. Results The overall highest mean wear of enamel (9.88 ± 1.73 µm) was observed in the control group (G1), where no fluoride gel was applied. It was significantly higher (p < 0.001) compared to all other groups. G2 (5.03 ± 1.43 µm), G3 (5.47 ± 0.63 µm, p = 0.918) and G4 (5.14 ± 0.82 µm, p > 0.999) showed the overall best protection from hydrochloric acid induced erosion. Enamel wear in G5 (6.64 ± 0.86 µm) was significantly higher compared to G2 (p = 0.028) and G4 (p = 0.047). Conclusions After 20 days of daily application, all investigated fluoride gels are able to significantly reduce gastroesophageal reflux induced loss of enamel.


2009 ◽  
Vol 20 (1) ◽  
pp. 42-47 ◽  
Author(s):  
Fernando Henrique Ruppel Osternack ◽  
Danilo Biazzetto de Menezes Caldas ◽  
Rodrigo Nunes Rached ◽  
Sérgio Vieira ◽  
Jeffrey A. Platt ◽  
...  

This in vitro study evaluated the Knoop hardness of the composite resins Charisma® (C) and Durafill VS® (D) polymerized in 3 different conditions: at room temperature (A) (23 ± 1°C); refrigerated at 4 ± 1°C and immediately photo-activated after removal from the refrigerator (0); and, refrigerated at 4 ± 1°C and photo-activated after a bench time of 15 min at room temperature (15). One hundred and twenty specimens (4 mm diameter and 2 mm depth) were made using a stainless steel mold and following manufacturer's instructions. All specimens were tested immediately after polymerization (I) and after 7 days of water storage in the dark at room temperature (7d). The data were subjected to ANOVA and post-hoc Tukey's test (a=0.05). On the top surface, CAI was statistically similar to C15I and DAI to D15I (p>0.05). On the bottom surface, CAI presented higher hardness values when compared to COI and C15I (p<0.05). The D groups showed no significant differences (p>0.05) on the bottom surfaces for any tested polymerization condition. After 7 days of storage, the Knoop hardness decreased significantly (p<0.05) for groups C7d and D7d except for C07d, which was not different from COI at either surface (p>0.05). D07d showed higher Knoop hardness (p<0.05) values on the top surface when compared to the other groups.


Materials ◽  
2021 ◽  
Vol 14 (22) ◽  
pp. 6753
Author(s):  
Ramona S. Oltramare ◽  
Reto Odermatt ◽  
Phoebe Burrer ◽  
Thomas Attin ◽  
Tobias T. Tauböck

The aim of this in vitro study was to investigate the degree of C=C double bond conversion of high-viscosity dimethacrylate- or ormocer-based bulk-fill composites as a function of measurement depth. Four bulk-fill composites (Tetric EvoCeram Bulk Fill, x-tra fil, SonicFill, and Bulk Ormocer) and the conventional nanohybrid composite Tetric EvoCeram were applied in standardized Class II cavities (n = 6 per group) and photoactivated for 20 s at 1350 mW/cm2. The degree of conversion of the composites was assessed using Fourier-transform infrared spectroscopy at seven measurement depths (0.15, 1, 2, 3, 4, 5, 6 mm). Data were analyzed using repeated measures ANOVA and one-way ANOVA with Bonferroni post-hoc tests (α = 0.05). The investigated bulk-fill composites showed at least 80% of their maximum degree of conversion (80% DCmax) up to a measuring depth of at least 4 mm. Tetric EvoCeram Bulk Fill and Bulk Ormocer achieved more than 80% DCmax up to a measuring depth of 5 mm, x-tra fil up to 6 mm. The conventional nanohybrid composite Tetric EvoCeram achieved more than 80% DCmax up to 3 mm. In contrast to the conventional composite, the investigated ormocer- and dimethacrylate-based bulk-fill composites can be photo-polymerized in thick layers of up to at least 4 mm with regard to their degree of C=C double bond conversion.


Sign in / Sign up

Export Citation Format

Share Document