scholarly journals A Fast Approach for Predicting Aerodynamic Noise Sources of High-Speed Train Running in Tunnel

2022 ◽  
Vol 130 (3) ◽  
pp. 1371-1386
Author(s):  
Deng Qin ◽  
Tian Li ◽  
Honglin Wang ◽  
Jizhong Yang ◽  
Yao Jiang ◽  
...  
2016 ◽  
Vol 2016 ◽  
pp. 1-21 ◽  
Author(s):  
Yadong Zhang ◽  
Jiye Zhang ◽  
Tian Li ◽  
Liang Zhang ◽  
Weihua Zhang

A broadband noise source model based on Lighthill’s acoustic theory was used to perform numerical simulations of the aerodynamic noise sources for a high-speed train. The near-field unsteady flow around a high-speed train was analysed based on a delayed detached-eddy simulation (DDES) using the finite volume method with high-order difference schemes. The far-field aerodynamic noise from a high-speed train was predicted using a computational fluid dynamics (CFD)/Ffowcs Williams-Hawkings (FW-H) acoustic analogy. An analysis of noise reduction methods based on the main noise sources was performed. An aerodynamic noise model for a full-scale high-speed train, including three coaches with six bogies, two inter-coach spacings, two windscreen wipers, and two pantographs, was established. Several low-noise design improvements for the high-speed train were identified, based primarily on the main noise sources; these improvements included the choice of the knuckle-downstream or knuckle-upstream pantograph orientation as well as different pantograph fairing structures, pantograph fairing installation positions, pantograph lifting configurations, inter-coach spacings, and bogie skirt boards. Based on the analysis, we designed a low-noise structure for a full-scale high-speed train with an average sound pressure level (SPL) 3.2 dB(A) lower than that of the original train. Thus, the noise reduction design goal was achieved. In addition, the accuracy of the aerodynamic noise calculation method was demonstrated via experimental wind tunnel tests.


2019 ◽  
Vol 9 (11) ◽  
pp. 2332 ◽  
Author(s):  
Yongfang Yao ◽  
Zhenxu Sun ◽  
Guowei Yang ◽  
Wen Liu ◽  
Prasert Prapamonthon

The high-speed-train pantograph is a complex structure that consists of different rod-shaped and rectangular surfaces. Flow phenomena around the pantograph are complicated and can cause a large proportion of aerodynamic noise, which is one of the main aerodynamic noise sources of a high-speed train. Therefore, better understanding of aerodynamic noise characteristics is needed. In this study, the large eddy simulation (LES) coupled with the acoustic finite element method (FEM) is applied to analyze aerodynamic noise characteristics of a high-speed train with a pantograph installed on different configurations of the roof base, i.e. flush and sunken surfaces. Numerical results are presented in terms of acoustic pressure spectra and distributions of aerodynamic noise in near-field and far-field regions under up- and down-pantograph as well as flushed and sunken pantograph base conditions. The results show that the pantograph with the sunken base configuration provides better aerodynamic noise performances when compared to that with the flush base configuration. The noise induced by the down-pantograph is higher than that by the up-pantograph under the same condition under the pantograph shape and opening direction selected in this paper. The results also indicate that, in general, the directivity of the noise induced by the down-pantograph with sunken base configuration is slighter than that with the flush configuration. However, for the up-pantograph, the directivity is close to each other in Y-Z or X-Z plane whether it is under flush or sunken roof base condition. However, the sunken installation is still conducive to the noise environment on both sides of the track.


Author(s):  
Hogun Kim ◽  
Zhiwei Hu ◽  
David Thompson

For high-speed trains, the aerodynamic noise becomes an essential consideration in the train design. The pantograph and pantograph recess are recognised as important sources of aerodynamic noise. This paper studies the flow characteristics and noise contributions of three typical high-speed train roof configurations, namely a cavity, a ramped cavity and a flat roof with side insulation plates. The Improved Delayed Detached-Eddy Simulation approach is used for the flow calculations and the Ffowcs Williams & Hawkings aeroacoustic analogy is used for far-field acoustic predictions. Simulations are presented for a simplified train body at 1/10 scale and 300 km/h with these three roof configurations. In each case, two simplified pantographs (one retracted and one raised) are located on the roof. Analysis of the flow fields obtained from numerical simulations clearly shows the influence of the train roof configuration on the flow behaviour, including flow separations, reattachment and vortex shedding, which are potential noise sources. A highly unsteady flow occurs downstream when the train roof has a cavity or ramped cavity due to flow separation at the cavity trailing edge, while vortical flow is generated by the side insulation plates. For the ramped cavity configuration, moderately large pressure fluctuations appear on the cavity outside walls in the upstream region due to unsteady flow from the upstream edge of the plate. The raised pantograph, roof cavity, and ramped cavity are identified as the dominant noise sources. When the retracted pantograph is located in the ramped roof cavity, its noise contribution is less important. Furthermore, the insulation plates also generate tonal components in the noise spectra. Of the three configurations considered, the roof cavity configuration radiates the least noise at the side receiver in terms of A-weighted level.


Complexity ◽  
2018 ◽  
Vol 2018 ◽  
pp. 1-19 ◽  
Author(s):  
Xiao-Ming Tan ◽  
Hui-fang Liu ◽  
Zhi-Gang Yang ◽  
Jie Zhang ◽  
Zhong-gang Wang ◽  
...  

We aim to study the characteristics and mechanism of the aerodynamic noise sources for a high-speed train in a tunnel at the speeds of 50 m/s, 70 m/s, 83 m/s, and 97 m/s by means of the numerical wind tunnel model and the nonreflective boundary condition. First, the large eddy simulation model was used to simulate the fluctuating flow field around a 1/8 scale model of a high-speed train that consists of three connected vehicles with bogies in the tunnel. Next, the spectral characteristics of the aerodynamic noise source for the high-speed train were obtained by performing a Fourier transform on the fluctuating pressure. Finally, the mechanism of the aerodynamic noise was studied using the sound theory of cavity flow and the flow field structure. The results show that the spectrum pattern of the sound source energy presented broadband and multipeak characteristics for the high-speed train. The dominant distribution frequency range is from 100 Hz to 4 kHz for the high-speed train, accounting for approximately 95.1% of the total sound source energy. The peak frequencies are 400 Hz and 800 Hz. The sound source energy at 400 Hz and 800 Hz is primarily from the bogie cavities. The spectrum pattern of the sound source energy has frequency similarity for the bottom structure of the streamlined part of the head vehicle. The induced mode of the sound source energy is probably the dynamic oscillation mode of the cavity and the resonant oscillation mode of the cavity for the under-car structure at 400 Hz and 800 Hz, respectively. The numerical computation model was checked by the wind tunnel test results.


2013 ◽  
Vol 664 ◽  
pp. 191-196
Author(s):  
You Gang Xiao ◽  
Yu Shi

For clarifying the noise in tunnel affected by pantograph and bogie, which are the most important noise sources, the noises near pantograph and bogie in a high-speed train were tested by multi-channel noise measurement and analysis system in tunnel, and compared with those measured outside the High-speed train and on an open field. The results show that the interior vehicle noise is spatially non-homogeneous in the whole carriage, the larger sound pressure level (SPL) near pantograph are next to ceiling, and near bogie next to floor. The noise spectra show a broad band feature, and dominated by the frequency contents among 100Hz-2kHz, so the countermeasures against noise should be within these range.


2018 ◽  
Vol 2018 ◽  
pp. 1-13 ◽  
Author(s):  
Jie Zhang ◽  
Xinbiao Xiao ◽  
Dewei Wang ◽  
Yan Yang ◽  
Jing Fan

This paper presents a detailed investigation into the contributions of different sound sources to the exterior noise of a high-speed train both experimentally and by simulations. The in situ exterior noise measurements of the high-speed train, including pass-by noise and noise source identification, are carried out on a viaduct. Pass-by noise characteristics, noise source localizations, noise source contributions of different regions, and noise source vertical distributions are considered in the data analysis, and it is shown how they are affected by the train speed. An exterior noise simulation model of the high-speed train is established based on the method of ray acoustics, and the inputs come from the array measurements. The predicted results are generally in good agreement with the measurements. The results show that for the high-speed train investigated in this paper, the sources with the highest levels are located at bogie and pantograph regions. The contributions of the noise sources in the carbody region on the pass-by noise increase with an increasing distance, while those in the bogie and train head decrease. The source contribution rates of the bogie and the lower region decrease with increasing train speed, while those of the coach centre increase. At a distance of 25 m, the effect of the different sound sources control on the pass-by noise is analysed, namely, the lower region, bogie, coach centre, roof region, and pantograph. This study can provide a basis for exterior noise control of high-speed trains.


Author(s):  
Sidharath Sharma ◽  
Jorge García-Tíscar ◽  
John M. Allport ◽  
Martyn L. Jupp ◽  
Ambrose K. Nickson

Ported shroud casing treatment is widely used to delay the onset of surge and thereby enhancing the aerodynamic stability of a centrifugal compressor by recirculating the low momentum fluid in the blade passage. Performance losses associated with the use of recirculation casing treatment are well established in the literature and this is an area of active research. The other, less researched aspect of the casing treatment is its impact on the acoustics of the compressor. This work investigates the impact of ported shroud casing treatment on the acoustic characteristics of the compressor. The flow in two compressor configurations viz. with and without casing treatment operating at the design operating conditions of an iso-speed line are numerically modelled and validated with experimental data from gas stand measurements. The pressure fluctuations calculated as the flow solution are used to compute the spectral signatures at multiple locations to investigate the acoustic phenomenon associated with each configuration. Propagation of the frequency content through the ducts has been estimated with the aid of method of characteristics to enhance the content coming from the compressor. Expected tonal aerodynamic noise sources such as monopole (buzz-saw tones) and dipole (Blade Pass Frequency) are clearly identified in the acoustic spectra of the two configurations. The comparison of two configurations shows higher overall levels and tonal content in the case of a compressor with ported shroud operating at design conditions due to the presence of ‘mid-tones’.


Sign in / Sign up

Export Citation Format

Share Document