scholarly journals Development and Validation of a Fast and Selective HPLC Method for the Determination of Amphotericin B in Nose-to-Brain Nanoliposome

2020 ◽  
Vol 10 (2) ◽  
pp. 2309-2319

A simple, fast, and selective HPLC method is presented to quantified amphotericin B (AmB) in a nose-to-brain nanoliposomal pharmaceutical formulation. The development was based on the design of experiments (DoE) approach. The chromatographic analysis was validated on a C18 Zorbax reversed-phase column (250 mm x 4,6 mm I.D.) with 5 µm of particle size using mobile phase, consisting of a binary mixture of ultra-purified water and an organic composition of acetonitrile, methanol, and tetrahydrofuran (75:17:8, v/v). The isocratic flow rate was 1.0 mL.min-1, and the detection at 383 nm. The 12 minutes running time being selective between the main peak from possible degradation products, linear and accurate for the concentration range of 0.5 to 7.0 μg.mL-1, and precise demonstrating a relative standard deviation of 0.01 % (n = 6). Application of this method to assay and stability studies of AmB in nanoliposomal lipid-based is provided.

2016 ◽  
Vol 8 (30) ◽  
pp. 5949-5956 ◽  
Author(s):  
Soumia Boulahlib ◽  
Ali Boudina ◽  
Kahina Si-Ahmed ◽  
Yassine Bessekhouad ◽  
Mohamed Trari

In this study, a rapid and simple method based on reversed-phase high performance liquid chromatography (RP-HPLC) using a photodiode array detector (PDA) for the simultaneous analysis of five pollutants including aniline and its degradation products, para-aminophenol, meta-aminophenol, ortho-aminophenol and phenol, was developed.


2011 ◽  
Vol 94 (4) ◽  
pp. 1089-1093 ◽  
Author(s):  
Fernando Henrique Andrade Nogueira ◽  
Letícia De Paula Lana Goulart ◽  
Isabela Da Costa César ◽  
Lígia Maria Moreira De Campos ◽  
Gérson Antônios Pianetti

Abstract A simple HPLC method for determination of mefloquine hydrochloride in tablets was developed and validated. The separation was carried out on an Xterra RP18 (250 × 4.6 mm id, 5 µm particle size) analytical column. The mobile phase was 0.05 M monobasic potassium phosphate buffer (pH 3.5)–methanol (40 + 60, v/v). The flow rate and wavelength were set to 1 mL/min and 283 nm, respectively. The method was specifc for mefloquine hydrochloride in the presence of hydrolytic, oxidative, and photolytic degradation products. It was also linear, precise, accurate, and robust, being suitable for routine QC analyses and stability studies. The developed HPLC method was compared to a previously described spectrophotometric method.


2020 ◽  
Vol 32 (1) ◽  
pp. 39-43
Author(s):  
Abdul Shakoor ◽  
Mahmood Ahmed ◽  
Rabia Ikram ◽  
Sajad Hussain ◽  
Arifa Tahir ◽  
...  

The present work aimed to develop and validate a simple, rapid, sensitive, accurate, and precise method for simultaneous determination of metformin hydrochloride and vildagliptin in tablet and biological samples. Isocratic elution of both the analytes was performed at 35 °C by injecting 20 μL into Thermo Hypersil ODS C18 column (5 μm, 4.6 mm× 250 mm), while the flow rate was set to 0.8 mL/min. The mobile phase comprised of methanol, acetonitrile, and phosphate buffer (5:30:65, v/v, pH 3.5), and wavelength was selected at 212 nm. The overall run time per sample was 7.0 min with a retention time of 3.36 and 5.41 min for metformin hydrochloride and vildagliptin, respectively. The calibration curve was linear from 10–140 μg/mL for metformin and 1–14 μg/mL for vildagliptin with a coefficient of determination (R2) ≤ 0.9919, while repeatability and reproducibility (expressed as relative standard deviation) were lower than 1.13 and 0.97%, respectively. Force degradation studies indicated a complete separation of the analytes in the presence of their degradation products providing a high degree of method specificity. The proposed reversed-phase high-performance liquid chromatography (RP-HPLC) method was demonstrated to be simple and rapid for the determination of metformin hydrochloride and vildagliptin in commercially available tablet and biological samples providing recoveries ranged between 100.13–100.29%.


2006 ◽  
Vol 89 (6) ◽  
pp. 1552-1556
Author(s):  
ArmaĞan Önal ◽  
Olcay SaĞiri ◽  
S Müge Çetin ◽  
Sidika Toker

Abstract Reboxetine is used as a selective noradrenaline reuptake inhibitor for the treatment of major depressive disorders. It is effective in the treatment of severe depression and safer to use than traditional tricyclic antidepressants. In this study, a novel, simple, and rapid stability-indicating high-performance liquid chromatography (HPLC) method for reboxetine methansulfonate was successfully developed and validated for the assay of tablets. The method was used to quantify reboxetine in tablets; it employed a C18 column (150 4.6 mm id) with an isocratic mobile phase consisting of methanolphosphate buffer (pH 7, 0.02 M; 55 + 45, v/v) at a flow rate of 1.0 μmL/min. Reboxetine was detected by an ultraviolet detector at 277 nm. The retention time of reboxetine was about 4.5 min. The developed HPLC method was validated with respect to linearity, precision, sensitivity, accuracy, and selectivity. The method was linear over the concentration range 150 g/mL (r 0.9999). The limits of detection and the quantitation of reboxetine were 0.1 and 0.3 μg/mL, respectively. The relative standard deviation values for intraday and interday precision were 0.781.01 and 1.081.37%, respectively. Selectivity was validated by subjecting a stock solution of reboxetine to neutral, acid, and alkali hydrolysis, as well as oxidation, dry heat treatment, and photodegradation. The peaks of the degradation products did not interfere with the peak of reboxetine. The results indicated that the proposed method could be used in a stability assay. The proposed method was successfully applied to the determination of reboxetine in tablets. Excipients present in the tablets did not interfere with the analysis.


INDIAN DRUGS ◽  
2014 ◽  
Vol 51 (02) ◽  
pp. 16-20
Author(s):  
L Mohankrishna ◽  
◽  
P. J. Reddy ◽  
B. P Reddy. ◽  
P. Navya

A sensitive and precise HPLC procedure has been developed for the assay of amphotericin B in bulk samples and pharmaceutical formulations by using a C18 column [Kromosil, C18, (5 µm, 4.6mm x 250 mm; Make. Waters)], and mobile phase combination is 1% formic acid in water and acetonitrile in ratio of 45:55 V/V. The procedure has been validated as per the ICH guidelines. The λmax of detection was fixed at 407 nm, so that there was less interference from mobile phase with highest sensitivity according to UV analysis. Calibration plots were linear in the range of 10-100 µg/mL and the LOD and LOQ were 0.02 µg/mL and 0.06 µg/mL respectively. The high recovery and low relative standard deviation confirm the suitability of the method for routine quality control determination of amphotericin B in different formulations.


Author(s):  
V.L.N. Balaji Gupta Tiruveedhi ◽  
Venkateswara Rao Battula ◽  
Kishore Babu Bonige ◽  
Tejeswarudu B.

This research work was designed to establish and validate a novel stability indicating RP-HPLC method for the combined determination of Benidipine hydrochloride (BHE) and Nebivolol hydrochloride (NHE) in bulk and tablets, dependent on ICH guidelines.The assay method to analyse BHE and NHE was optimized with isocratic elution using acetonitrile: 0.1M acetate buffer (45:55, pH 5.1), Lichrospher ODS RP-18 column and flow pace of 1 ml/min. Total time for single run was 14 min. The injection quantity was 20μl, and was detected at 249nm. The method was verified on a concentration series of 1.25-10μg/ml (NHE) and 1.0-10μg/ml (BHE) for precision, accuracy and linearity. The LOD values were 0.059µg/ml and 0.028µg/ml for NHE and BHE, respectively. The LOQ values were 0.196µg/ml for NHE and 0.094µg/ml for BHE. The recovery percentages were 98.60-100.11% (BHE) and 98.94-101.50% (NHE) with relative standard deviation 0.250-0.694% (BHE) and 0.183-0.400% (NHE). The method was also observed to be efficient, and was sufficiently specific to measure BHE and NHE in the presence of stress-produced degradation products.


2012 ◽  
Vol 48 (2) ◽  
pp. 315-323 ◽  
Author(s):  
Paulo Cesar Pires Rosa ◽  
Isabel Cristina Sales Fontes Jardim

A new, simple, fast, reproducible and sensitive reversed phase HPLC method, using a new stationary phase containing embedded urea polar groups, has been developed and validated for the simultaneous determination of clobutinol hydrochloride (CLO) and doxylamine succinate (DOX) in syrups. The determination was carried out on a C8 urea column (125 mm x 3.9 mm i.d., 5 µm particle size) synthetized at the Liquid Chomatography Laboratory (LabCrom) of the Chemistry Institute of Unicamp. The mobile phase consisted of a mixture of acetonitrile:methanol:phosphate buffer (pH 2.5) in the gradient mode. The diode array detector (DAD) was operated at 230 nm for CLO and 262 nm for DOX. The method showed adequate precision, with relative standard deviations (RSD) less than 1%. The presence of the excipients did not interfere in the results of the analysis. Accuracy was determined by adding standards of the drugs to a placebo and good recovery values were obtained. The analytical curves were linear (r² 0.9999 for CLO and 0.9998 for DOX) over a wide concentration range (2.4-336 µg mL-1 for CLO and 2.3-63 µg mL-1 for DOX). The solutions were stable for at least 72 hours at room temperature. The criteria for validation using the ICH guidelines were fulfilled.


2021 ◽  
pp. 281-294 ◽  
Author(s):  
Abolghasem Beheshti ◽  
Zahra Kamalzadeha ◽  
Monireh Haj-Maleka ◽  
Meghdad Payaba ◽  
Mohammad Amin Rezvanfar ◽  
...  

Due to the new hopes for treatment of multiple sclerosis (MS) diseases by Teriflunomide (TFN), in this project, a cheap, robust, and fully validated method has been developed both for determination of assay content in API (active pharmaceutical ingredient), and for related impurities analysis (RIA). To operate the method, a common C18, end-capped (250 × 4.6) mm, 5µm liquid chromatography column, was applied. The mobile phase A was prepared by dissolving 2.74 g (20mM) of PDP (potassium dihydrogen phosphate) and 3.72 g (50mM) of PC (potassium chloride) in water (1000 mL). Then, pH was adjusted to 3.0 by adding OPA (ortho-phosphoric acid) 85%; while, the mobile phase B was acetonitrile (ACN) (100%). In order to confirm the experimental data about the λmax of TFN, we have used the Born-Oppenheimer molecular dynamics (BOMD) simulations, quantum mechanics (QM), and TD-DFT calculations. According to the results, the method showed a high level of suitability, specificity, linearity, accuracy, precision, repeatability, robustness, and reliable detection limit.


INDIAN DRUGS ◽  
2019 ◽  
Vol 56 (07) ◽  
pp. 43-49
Author(s):  
B.P. Manjula ◽  
V. G Joshi ◽  
Siddamsetty Ramachandra Setty ◽  
M Geetha ◽  

Tea tree oil, an active ingredient of skin, hair and nail care cosmeceuticals, has claims for topical antimicrobial, analgesic and anti-inflammatory activity. Its complex composition is governed by ISO 4730:2017. Terpinene-4-ol is the principal constituent of the oil (35% - 48%) followed by γ-terpinene (14% -28%), α-terpinene (6%-12%) and 1,8-cineole (≤15%). A reversed-phase, isocratic high performance liquid chromatographic method has been developed and validated for routine determination of tea tree oil based on1,8-cineole content in bulk and commercially available cosmeceuticals using C18 column, methanol-water (70:30 v/v) as mobile phase and flow rate of 1mL/min. UV detection was done at 200 nm. Linearity of the method was established for 20-100μL/mL (R2 = 0.9992) with LOD, LOQ values of 0.5594 μL/mL and 5.5941μL/mL respectively. The % RSD values for robustness and precision were <1% and recovery ranged between 99.09-102.96%. The method was successfully applied for determination of 1,8-cineole content in cosmeceuticals.


Sign in / Sign up

Export Citation Format

Share Document