scholarly journals In-House, Open-Source 3D-Software-Based, CAD/CAM-Planned Mandibular Reconstructions in 20 Consecutive Free Fibula Flap Cases: An Explorative Cross-Sectional Study With Three-Dimensional Performance Analysis

2021 ◽  
Vol 11 ◽  
Author(s):  
Lucas M. Ritschl ◽  
Paul Kilbertus ◽  
Florian D. Grill ◽  
Matthias Schwarz ◽  
Jochen Weitz ◽  
...  

BackgroundMandibular reconstruction is conventionally performed freehand, CAD/CAM-assisted, or by using partially adjustable resection aids. CAD/CAM-assisted reconstructions are usually done in cooperation with osteosynthesis manufacturers, which entails additional costs and longer lead time. The purpose of this study is to analyze an in-house, open-source software-based solution for virtual planning.Methods and MaterialsAll consecutive cases between January 2019 and April 2021 that underwent in-house, software-based (Blender) mandibular reconstruction with a free fibula flap (FFF) were included in this cross-sectional study. The pre- and postoperative Digital Imaging and Com munications in Medicine (DICOM) data were converted to standard tessellation language (STL) files. In addition to documenting general information (sex, age, indication for surgery, extent of resection, number of segments, duration of surgery, and ischemia time), conventional measurements and three-dimensional analysis methods (root mean square error [RMSE], mean surface distance [MSD], and Hausdorff distance [HD]) were used.ResultsTwenty consecutive cases were enrolled. Three-dimensional analysis of preoperative and virtually planned neomandibula models was associated with a median RMSE of 1.4 (0.4–7.2), MSD of 0.3 (-0.1–2.9), and HD of 0.7 (0.1–3.1). Three-dimensional comparison of preoperative and postoperative models showed a median RMSE of 2.2 (1.5–11.1), MSD of 0.5 (-0.6–6.1), and HD of 1.5 (1.1–6.5) and the differences were significantly different for RMSE (p < 0.001) and HD (p < 0.001). The difference was not significantly different for MSD (p = 0.554). Three-dimensional analysis of virtual and postoperative models had a median RMSE of 2.3 (1.3–10.7), MSD of -0.1 (-1.0–5.6), and HD of 1.7 (0.1–5.9).ConclusionsOpen-source software-based in-house planning is a feasible, inexpensive, and fast method that enables accurate reconstructions. Additionally, it is excellent for teaching purposes.

2016 ◽  
Vol 116 (3) ◽  
pp. 431-435 ◽  
Author(s):  
Paola C. Saponaro ◽  
Burak Yilmaz ◽  
Reza H. Heshmati ◽  
Edwin A. McGlumphy

2021 ◽  
Author(s):  
Yogita Gupta ◽  
Radhika Tandon

Abstract Purpose: To describe the variables that may be utilized in the optimization of three dimensional heads up surgeries (3D-HUS) for achieving better ergonomics among ophthalmic surgeons. Methods: A cross-sectional study conducted at the operating room of a tertiary eye care centre, equipped with ARTEVO 800 3D surgical microscope and display monitor. The parameters noted were: monitor height (MH), surgeon eye to floor distance (ETFD) surgeon eye to monitor distance (ETMD) (Fig. 1a) and viewing tilt (VT) angle. The neck and eye strain of the surgeon and assistant were scored as per Borg’s CR-10 scale, before and after surgeries.Results: 15 surgeries were analysed. The minimum ETMD was 51 inches and eye strain reduced with shorted ETMD. VT and ETFD was higher for right eye surgeries. The optimum MH was between 50 to 55 inches. Overall, neck strain and eye strain were in the range of 0-3 and 0-1, respectively.Conclusion: The various parameters affecting 3D image quality, neck and eye strain are: chair height, viewing tilt angle, eye centration, monitor distance, laterality of the eye and room illumination.


CRANIO® ◽  
2018 ◽  
Vol 38 (5) ◽  
pp. 320-326 ◽  
Author(s):  
Alessandro Nota ◽  
Silvia Caruso ◽  
Shideh Ehsani ◽  
Alberto Baldini ◽  
Simona Tecco

PLoS ONE ◽  
2019 ◽  
Vol 14 (7) ◽  
pp. e0219451 ◽  
Author(s):  
Chihiro Tanikawa ◽  
Sadaki Takata ◽  
Ruriko Takano ◽  
Haruna Yamanami ◽  
Zere Edlira ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document