scholarly journals The Modification Mechanism of Nano-Liquids on Streamer Morphology and Breakdown Strength under Microsecond Pulse

2020 ◽  
Vol 10 (20) ◽  
pp. 7376
Author(s):  
Diangeng Li ◽  
Zicheng Zhang ◽  
Shifei Liu ◽  
Song Li

In liquid mediums, whether the breakdown strength can be greatly improved after introducing the nano-particles has been widely investigated, however, there has been no scientific consensus on the modification mechanism of this anomalous phenomenon. In this paper, we first experimentally measured the streamer morphology and breakdown strength in pure transformer oil, TiO2 nano-liquids and Al2O3 nano-liquids under microsecond pulse. The results demonstrated that there are significant differences in streamer morphology between pure transformer oil and nano-liquids, as the streamers in pure transformer oil exhibit thick bush-like qualities, while in nano-liquids they exhibit tree-like qualities. Moreover, the breakdown voltage results show that the breakdown strength of transformer oil is improved after nano-modification, and the TiO2 nano-liquids and Al2O3 nano-liquids have nearly the same optimal volume fraction. The results of the analysis indicate that the modification mechanism of nano-particles is significantly linked to the trapped electrons process. Specifically, the addition of nano-particles can affect the electrons’ density and thus affect the breakdown process and streamer morphology.

Materials ◽  
2018 ◽  
Vol 11 (12) ◽  
pp. 2373 ◽  
Author(s):  
Wenxin Tian ◽  
Chao Tang ◽  
Qian Wang ◽  
Shiling Zhang ◽  
Yali Yang

Moisture has a significant effect on the internal insulation performance of transformers, and is closely related to the breakdown voltage of transformer insulating oil. In the present work, we studied the effect of nano-SiO2 particles on the diffusion of water in insulating naphthenic mineral oil using molecular dynamics simulation. Six models were established, three of which contained nano-SiO2 particles together with water concentration of 1 wt.%, 2 wt.%, or 3 wt.%. For each model variations in free volume, mean square displacement, and interaction energy were assessed. The addition of nano SiO2 particles was found to reduce the free volume fraction of the model and as well as the free motion of water molecules in the oil. These particles also increased the interaction between the oil and water molecules, indicating that insulating oil containing nano-particles has a greater binding effect on water. The diffusion coefficient of water in oil containing nano-SiO2 particles was reduced, such that water molecules were less likely to diffuse. The results also show that these particles adsorb water molecules in the oil and to reduce diffusion. Consequently, the addition nano-scale SiO2 particles could potentially improve the breakdown voltage of the insulating oil.


2016 ◽  
Vol 2016 ◽  
pp. 1-6 ◽  
Author(s):  
Qi Wang ◽  
Muhammad Rafiq ◽  
Yuzhen Lv ◽  
Chengrong Li ◽  
Kai Yi

Nanofluids have the potential to become the alternatives of conventional transformer oil for their exquisite electrical and thermal properties. Three kinds of nanoparticles with distinct conductivities, namely, nonconductive nanoparticle Al2O3, conductive nanoparticle Fe3O4, and semiconductive nanoparticle TiO2, with different concentrations from 5% to 40% w/v were selected and suspended into transformer oil to develop nanofluids. The lightening impulse breakdown strengths of the oil samples with and without nanoparticles were measured according to IEC standard methods. The positive impulse breakdown strength indicated that breakdown strength is first increased up to the maximum value at certain concentration and then starts decreasing. The results of negative impulse breakdown manifested that the breakdown voltages of nanofluids with different concentrations were less than the breakdown voltage of pure transformer oil. Different effect mechanisms of dielectric and conductive nanoparticles were also used to describe the difference among three prepared nanofluids.


2015 ◽  
Vol 1119 ◽  
pp. 175-178 ◽  
Author(s):  
Wittawat Saenkhumwong ◽  
Amnart Suksri

Transformer is one of the major component, which is the most important device in power system. Their lifetime depends upon liquid insulation that help transfer the heat out of its winding inside of transformer. Transformer oil uses mineral oil that is the most commonly used has very slow process on decomposition and non-biodegrade. This paper presents the investigation on breakdown voltage of two types of natural ester oils, including palm oil and soy bean based-on ZnO nanofluids. Nanofluids that use nanoparticles modified by use of surfactant that are suspended by process of sonication. Different fraction of nanoparticles were investigated from 0.1% - 0.5% by weight. The breakdown voltage were measured according to ASTM D877. The voltage breakdown strength increased significantly when nanoparticles were added in oils. The obtained results will enable transformer industry to develop liquid insulation dielectric for use in transformer in the future.


2020 ◽  
Vol 8 (2) ◽  
pp. 77-81
Author(s):  
Amelya Indah Pratiwi

The failure of transformer insulation often occurs due to various kinds of things, one of which is failure in the oil isolation caused by the condition of oil that has been dirty or has been contaminated with other particles in the transformer. Phenol is a chemical that can purify or cleanse particles or impurities that are in used transformer oil, so that it can increase the breakdown stress on used insulation oil. Phenol contains acid which can attract particles and impurities in the transformer oil which results in a decrease in the breakdown strength of the insulating oil. The results of testing of used isolation oil by adding phenol as much as 10, 15 and 20 ml showed an increase in the value of breakdown voltage with a distance of 2.5 mm ball inlet electrode. Translucent stresses that meet the SPLN standard 49-1: 1982, that is ≥ 30 kV at intervals of 2.5 mm were obtained by adding 20 ml of phenol to the volume of used 400 ml transformer oil


Vestnik IGEU ◽  
2020 ◽  
pp. 48-55
Author(s):  
O.S. Melnikova ◽  
V.S. Kuznetsov

The most damage-sensitive unit of power transformers is the main insulation of the oil barrier type. The breakdown of such insulation occurs as a result of the breakdown of the oil channel near the high voltage winding. In accordance with traditional methods of calculating the dielectric strength of insulation, the value of the breakdown strength is determined by empirical formulas depending on the selected width of the oil channel. The existing methods do not consider the influence of the oil channel volume, of the electric strength the statistical characteristics of the oil, the design features of the insulation of power transformers, and do not contain recommendations for creating design models. Thus, to improve the calculation accuracy, it is relevant to develop the evaluation method of dielectric strength of the main insulation of power transformers taking into account the volume and parameters of the breakdown voltage distribution of transformer oil, design features. The research results of the breakdown tension in oil channels with different volumes of transformer oil were used. To improve the accuracy of the calculation and taking into account the design features, the model of the main insulation of power transformers was made in the ANSYS program. Boundary data and assumption of linear stress distribution of transformer coils were considered. A method for calculating the dielectric strength of oil channels of the main insulation of power transformers, considering the volume and parameters of the breakdown voltage distribution of transformer oil was proposed. Unlike the existing methods, when calculating the minimum breakdown strength in the model of the main insulation, the design features of power transformers are taken into account and assumptions are justified to improve the accuracy of the calculation. In accordance with the methodology, the parameters of the dielectric strength of the transformer oil in the oil channel of the high voltage winding of the transformer were calculated. It was concluded that with increase of relative value of breakdown tension, dielectric strength of oil channel is decreasing, and it corresponds to physical sense of breakdown. The method for calculating the dielectric strength of transformer oil can be used when choosing the main insulation of power transformers in design.


Vestnik IGEU ◽  
2020 ◽  
pp. 23-33
Author(s):  
O.S. Melnikova ◽  
M.V. Prusakov ◽  
A.A. Zholobov

The electrical strength of transformer oil is the first parameter in transformer insulation tests. Such tests are carried out in a standard discharger according to the values of breakdown voltage. An abrupt decrease in electrical strength occurs when oil is contaminated with mechanical impurities. The greatest influence on the electric field is exerted by highly conductive cellulose fibers. The field between the electrodes may be severely distorted bya «bridge» of such fibers. At the same time, the influence of such particles is not taken into account in the tests. The problem is to experimentally determine the effect of such impurities on the breakdown strength. Thereby, this research poses and solves the problem of determining the dielectric strength of transformer oil in a standard discharger in the presence of cellulose fibers.To simulate electric field strengths, the ANSYS software package has been used. The basis of the 3D model was a standard measuring cell for determining breakdown voltage, which takes into account the boundary conditions in the form of a cube in which the electrode system is located, and the values of the electric field strength in the center of the electrode system.The electric field tension between the electrodes has been calculated, taking into account the influence of increased conductivity of cellulose fibers. It has been found that the electrical strength of oil gaps of moistened fibers with a length of more than 200 μm is significantly reduced, which is not taken into account when testing transformer oil for breakdown in a standard cell. This leads to inaccuracy in determining the electric strength of transformer oil in existing equipment.The results of the study can be used by operational services to improve the assessment of the quality of transformer oil used in power transformers as insulation. The results also can be used to study the mechanisms of electrophysical processes occurring in liquid dielectrics in the presence of fibers.


Materials ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 3610
Author(s):  
Norhafezaidi Mat Saman ◽  
Izzah Hazirah Zakaria ◽  
Mohd Hafizi Ahmad ◽  
Zulkurnain Abdul-Malek

Mineral oil has been chosen as an insulating liquid in power transformers due to its superior characteristics, such as being an effective insulation medium and a great cooling agent. Meanwhile, the performance of mineral oil as an insulation liquid can be further enhanced by dispersing nanoparticles into the mineral oil, and this composition is called nanofluids. However, the incorporation of nanoparticles into the mineral oil conventionally causes the nanoparticles to agglomerate and settle as sediment in the base fluid, thereby limiting the improvement of the insulation properties. In addition, limited studies have been reported for the transformer oil as a base fluid using Aluminum Oxide (Al2O3) as nanoparticles. Hence, this paper reported an experimental study to investigate the significant role of cold plasma treatment in modifying and treating the surface of nano-alumina to obtain a better interaction between the nano-alumina and the base fluid, consequently improving the insulation characteristics such as breakdown voltage, partial discharge characteristics, thermal conductivity, and viscosity of the nanofluids. The plasma treatment process was conducted on the surface of nano-alumina under atmospheric pressure plasma by using the dielectric barrier discharge concept. The breakdown strength and partial discharge characteristics of the nanofluids were measured according to IEC 60156 and IEC 60270 standards, respectively. In contrast, the viscosity and thermal conductivity of the nanofluids were determined using Brookfield DV-II + Pro Automated viscometer and Decagon KD2-Pro conductivity meter, respectively. The results indicate that the 0.1 wt% of plasma-treated alumina nanofluids has shown the most comprehensive improvements in electrical properties, dispersion stability, and thermal properties. Therefore, the plasma treatment has improved the nanoparticles dispersion and stability in nanofluids by providing stronger interactions between the mineral oil and the nanoparticles.


Materials ◽  
2021 ◽  
Vol 14 (5) ◽  
pp. 1298
Author(s):  
Farooq Aslam ◽  
Zhen Li ◽  
Guanghao Qu ◽  
Yang Feng ◽  
Shijun Li ◽  
...  

To date, breakdown voltage is an underlying risk to the epoxy-based electrical high voltage (HV) equipment. To improve the breakdown strength of epoxy resin and to explore the formation of charge traps, in this study, two types of polyhedral oligomeric silsesquioxane (POSS) fillers are doped into epoxy resin. The breakdown voltage test is performed to investigate the breakdown strength of neat epoxy and epoxy/POSS composites. Electron traps that play an important role in breakdown strength are characterized by thermally stimulated depolarized current (TSDC) measurement. A quantum chemical calculation tool identifies the source of traps. It is found that adding octa-glycidyl POSS (OG-POSS) to epoxy enhances the breakdown strength than that of neat epoxy and epoxycyclohexyl POSS (ECH-POSS) incorporated epoxy. Moreover, side groups of OG-POSS possess higher electron affinity (EA) and large electronegativity that introduces deep-level traps into epoxy resin and restrain the electron transport. In this work, the origin of traps has been investigated by the simulation method. It is revealed that the functional properties of POSS side group can tailor an extensive network of deep traps in the interfacial region with epoxy and enhance the breakdown strength of the epoxy/POSS nanocomposite.


Energies ◽  
2021 ◽  
Vol 14 (16) ◽  
pp. 5084
Author(s):  
Mardhiah Hayati Abdul Hamid ◽  
Mohd Taufiq Ishak ◽  
Nur Sabrina Suhaimi ◽  
Jaafar Adnan ◽  
Nazrul Fariq Makmor ◽  
...  

Transformer oil does not only serve as an insulating liquid, but also in removing heat from the windings and cores. Mineral oil (MO) has been widely used in transformers for more than 150 years. Recently, researchers have attempted to search for alternative insulating oils due to the possibility that MO will run out in the future together with the concern on fire safety and environmental pollution. Among the potential oils is rice bran oil (RBO). This work presents the studies of the lightning impulse (LI) of RBO behavior under various electric fields, gap distances and testing methods. The electrical performances of LI tests show that RBO and Palm Oil (PO) have lower LI breakdown voltage than MO under both uniform and non-uniform electric fields. However, the difference in LI breakdown voltages between RBO, PO and MO are slightly small which is less than 20%. In addition, there is no significant effect in the various testing methods under both uniform field and non-uniform field where the percentages of difference are less than 12% and 8% respectively. The data of LI breakdown voltage were statistically analysed to predict the withstand voltage and 50% breakdown voltage of oil samples by using Weibull distribution. The Weibull distribution of MO, PO and RBO has well fit with the fitting line. Finally, the relationship between LI voltages under a non-uniform field with various parameters of PO and RBO was obtained and proposed. From this work, it can be concluded that RBO shows promising results to be considered as an alternative to MO in transformer applications.


Sign in / Sign up

Export Citation Format

Share Document