scholarly journals Femtosecond Optical Laser System with Spatiotemporal Stabilization for Pump-Probe Experiments at SACLA

2020 ◽  
Vol 10 (21) ◽  
pp. 7934
Author(s):  
Tadashi Togashi ◽  
Shigeki Owada ◽  
Yuya Kubota ◽  
Keiichi Sueda ◽  
Tetsuo Katayama ◽  
...  

We constructed a synchronized femtosecond optical laser system with spatiotemporal stabilization for pump-probe experiments at SPring-8 Angstrom Compact Free Electron Laser (SACLA). Stabilization of output power and pointing has been achieved with a small fluctuation level of a few percent by controlling conditions of temperature and air-flow in the optical paths. A feedback system using a balanced optical-microwave phase detector (BOMPD) has been successfully realized to reduce jitter down to 50 fs. We demonstrated the temporal stability with a time-resolved X-ray diffraction measurement and observed the coherent phonon oscillation of the photo-excited Bi without the post-processing using the timing monitor.

2015 ◽  
Vol 22 (3) ◽  
pp. 503-507 ◽  
Author(s):  
Matthieu Chollet ◽  
Roberto Alonso-Mori ◽  
Marco Cammarata ◽  
Daniel Damiani ◽  
Jim Defever ◽  
...  

The X-ray Pump–Probe instrument achieves femtosecond time-resolution with hard X-ray methods using a free-electron laser source. It covers a photon energy range of 4–24 keV. A femtosecond optical laser system is available across a broad spectrum of wavelengths for generating transient states of matter. The instrument is designed to emphasize versatility and the scientific goals encompass ultrafast physical, chemical and biological processes involved in the transformation of matter and transfer of energy at the atomic scale.


2003 ◽  
Vol 770 ◽  
Author(s):  
Nathanael Smith ◽  
Max J. Lederer ◽  
Marek Samoc ◽  
Barry Luther-Davies ◽  
Robert G. Elliman

AbstractOptical pump-probe measurements were performed on planar slab waveguides containing silicon nanocrystals in an attempt to measure optical gain from photo-excited silicon nanocrystals. Two experiments were performed, one with a continuous-wave probe beam and a pulsed pump beam, giving a time resolution of approximately 25 ns, and the other with a pulsed pump and probe beam, giving a time resolution of approximately 10 ps. In both cases the intensity of the probe beam was found to be attenuated by the pump beam, with the attenuation increasing monotonically with increasing pump power. Time-resolved measurements using the first experimental arrangement showed that the probe signal recovered its initial intensity on a time scale of 45-70 μs, a value comparable to the exciton lifetime in Si nanocrystals. These data are shown to be consistent with an induced absorption process such as confined carrier absorption. No evidence for optical gain was observed.


2011 ◽  
Author(s):  
Lirong Ge ◽  
Min Shui ◽  
Xiao Jin ◽  
Zhongguo Li ◽  
Yinglin Song

2014 ◽  
Vol 70 (a1) ◽  
pp. C776-C776 ◽  
Author(s):  
Elzbieta Trzop ◽  
Bertrand Fournier ◽  
Katarzyna Jarzembska ◽  
Jesse Sokolow ◽  
Radoslaw Kaminski ◽  
...  

Thanks to their potential applications as light-emitting devices, chemical sensors and dye-sensitized solar cells, heteroleptic copper (I) complexes have been extensively studied. Cu(DPPE)(DMP)·PF6(dppe= 1,2-bis(diphenylphosphino)ethane; dmp = 2,9-dimethyl-1,10-phenanthroline) crystallizes in the monoclinic system, P21/c, with two independent molecules in the asymmetric unit. Previous studies on this system [1,2] show strong temperature-dependent emission. The complex was studied at 90K under 355nm laser excitation. At this temperature, the luminescence decay for Cu(DPPE)(DMP)·PF6is biexponential with lifetimes of ~3μs and ~28μs. Two time-resolved X-ray diffraction techniques were applied for studies: (1) a Laue technique at BioCARS ID-14 beamline at the Advanced Photon Source, and (2) monochromatic diffraction at a newly constructed in-house pump-probe monochromatic facility at the University at Buffalo. Structural changes determined with the two methods are in qualitative agreement; discrepancies in position of the Cu and P atoms were observed. The molecular distortions were smaller than those determined at 16K in the earlier synchrotron study by Vorontsov et al. [2]. Photodeformation maps (see Figure below), in which the increase in temperature on photoexcitation has been eliminated, clearly illustrate the photoinduced atomic shifts for both data sets. Results will be compared with those obtained for other studied heteroleptic copper (I) complexes, for instance Cu[(1,10-phenanthroline-N,N′) bis(triphenylphosphine)]·BF4[3]. The in-house pump-probe facility is discussed by Radoslaw Kaminski at this meeting. Research funded by the National Science Foundation (CHE1213223). BioCARS Sector 14 at APS is supported by NIH (RR007707). The Advanced Photon Source is funded by the Office of Basic Energy Sciences, U.S. Department of Energy, (W-31-109-ENG-38). KNJ is supported by the Polish Ministry of Science and Higher Education through the "Mobility Plus" program.


Author(s):  
Valérie Blanchet ◽  
Dominique Descamps ◽  
stephane Petit ◽  
Yann Mairesse ◽  
bernard Pons ◽  
...  

We study isomeric effects using time resolved photoelectron circular dichroism (PECD). By a (1+1’)pump-probe ionisation with photoelectron collected by velocity map imaging technique, we compare relaxation dynamics from the 3s-Rydberg...


2021 ◽  
Vol 28 (3) ◽  
Author(s):  
Matthias Rössle ◽  
Wolfram Leitenberger ◽  
Matthias Reinhardt ◽  
Azize Koç ◽  
Jan Pudell ◽  
...  

The time-resolved hard X-ray diffraction endstation KMC-3 XPP for optical pump/X-ray probe experiments at the electron storage ring BESSY II is dedicated to investigating the structural response of thin film samples and heterostructures after their excitation with ultrashort laser pulses and/or electric field pulses. It enables experiments with access to symmetric and asymmetric Bragg reflections via a four-circle diffractometer and it is possible to keep the sample in high vacuum and vary the sample temperature between ∼15 K and 350 K. The femtosecond laser system permanently installed at the beamline allows for optical excitation of the sample at 1028 nm. A non-linear optical setup enables the sample excitation also at 514 nm and 343 nm. A time-resolution of 17 ps is achieved with the `low-α' operation mode of the storage ring and an electronic variation of the delay between optical pump and hard X-ray probe pulse conveniently accesses picosecond to microsecond timescales. Direct time-resolved detection of the diffracted hard X-ray synchrotron pulses use a gated area pixel detector or a fast point detector in single photon counting mode. The range of experiments that are reliably conducted at the endstation and that detect structural dynamics of samples excited by laser pulses or electric fields are presented.


Sign in / Sign up

Export Citation Format

Share Document