scholarly journals Low-Intensity Pulsed Ultrasound Effect on MIO-M1 Cell Viability: Setup Validation and Standing Waves Analysis

2020 ◽  
Vol 11 (1) ◽  
pp. 271
Author(s):  
Irais Poblete-Naredo ◽  
Mario Ibrahin Gutierrez ◽  
Diana Estela Mendoza-Sánchez ◽  
Arturo Ortega ◽  
Arnulfo Albores ◽  
...  

Low-intensity pulsed ultrasound (LIPUS) has been proposed for novel therapies still under study, where similar parameters and protocols have been used for producing opposite effects that range from increasing cell viability to provoking cell death. Those divergent outcomes make the generalization of expected effects difficult for cell models not yet studied. This paper presents the effect of LIPUS on the viability of the MIO-M1 cell line for two well-established setups and different protocols; the acoustic intensities, duty factors, and treatment duration were varied. Measurements and models for acoustic and thermal analysis are included for proposing a solution to improve the reproducibility of this kind of experiments. Results indicate that MIO-M1 viability is less affected for the cells treated through a dish that is partially immersed in water; in these conditions, the cells neither show detrimental nor proliferative effects at intensities lower than 0.4 W/cm2 at 20% duty factor. However, cell viability was reduced when LIPUS was followed by cell subculturing. Treating the cells through a gel, with the culture dish placed on the transducer, increases cell mortality by the production of standing waves and mixed vibration-acoustical effects. Using the water-based setup with a 1° dish inclination reduces the effects of standing waves.

2021 ◽  
Author(s):  
Ra'ed Al-Dboush ◽  
Anahita Naseri Esfahani ◽  
Tarek El-Bialy

ABSTRACT Objective To assess the efficiency of low-intensity pulsed ultrasound (LIPUS) and photobiomodulation (PBM) interventions in accelerating orthodontic tooth movement during clear aligner therapy (CAT). Materials and Methods This retrospective study was carried out on the records of 84 subjects who were treated using CAT. Twenty-eight patients were treated using CAT with a daily use of LIPUS for 20 minutes, 28 patients were treated using CAT with a daily use of PBM for 10 minutes, and 28 patients were treated using CAT alone. The total duration of treatment was recorded for all patients. One-way analysis of variance and post hoc Tukey test were used to assess whether there was any significant difference in total treatment duration among the three groups (P < .05). Results The mean treatment durations in days were 719 ± 220, 533 ± 242, and 528 ± 323 for the control, LIPUS, and PBM groups, respectively. The LIPUS group showed a 26% reduction, on average, in treatment duration when compared with the control group, whereas the PBM group showed an average 26.6% reduction in the treatment duration when compared with the control group. The results showed that there were statistically significant differences among the groups (P = .011). Treatment durations were significantly reduced in the LIPUS and PBM groups as compared with the control (P = .027 and P = .023, respectively), with no statistically significant differences between the LIPUS and PBM groups (P = .998). Conclusions Daily use of LIPUS or PBM as adjunctive interventions during CAT could reduce the duration of orthodontic treatment.


2020 ◽  
Vol 9 (5) ◽  
pp. 1303
Author(s):  
Harmanpreet Kaur ◽  
Tarek El-Bialy

The aim of this retrospective clinical study was to determine if there is a reduction in the overall treatment duration in orthodontic patients using low-intensity pulsed ultrasound (LIPUS) and Invisalign SmartTrack® clear aligners. Data were collected from the first thirty-four patients (9 males, 25 females; average age 41.37 ± 15.02) who finished their orthodontic treatment using an intraoral LIPUS device and Invisalign clear aligners in a private clinic. The LIPUS parameters used by patients at home for 20 min/day were: ultrasonic frequency 1.5 MHz, pulse duration 200µs, pulse repetition rate 1 kHz, and spatial average-temporal average intensity 30mW/cm2. A control group (11 males, 23 females; average age 31.36 ± 14.41) matching for the same malocclusions was randomly selected from finished treatment cases of the same clinician. The date of first Invisalign attachment placement and first use of LIPUS application was recorded as T0, and the date of retainer delivery was recorded as T1. The treatment duration (T1–T0) and treatment reduction percentage with LIPUS device were collected and analyzed using two-sample t-test in Microsoft Excel. Treatment duration was significantly reduced in the LIPUS group (541.44 ± 192.23 days) compared to control group (1061.05 ± 455.64 days) (p < 0.05). The LIPUS group showed on average 49% reduction in the overall treatment time as compared to the control group. The average compliance of the patients using LIPUS was 66.02%. Patients who used LIPUS showed a clinically significant reduction in the overall orthodontic treatment duration compared to the control group who used Invisalign clear aligners only.


2020 ◽  
Vol 2020 ◽  
pp. 1-13
Author(s):  
Rong Zhang ◽  
Zhaoling Wang ◽  
Guoxiong Zhu ◽  
Gaoyi Wu ◽  
Qingyuan Guo ◽  
...  

Osteoradionecrosis of the jaw (ORNJ) is an infrequent yet potentially devastating complication of head and neck radiation therapy. Low-intensity pulsed ultrasound (LIPUS) has been widely accepted as a promising method for the successful management of ORNJ, but the mechanism remains unclear. In this study, the effects of LIPUS on cytoskeletal reorganization, cell viability, and osteogenic differentiation capacity of rat mandible-derived bone marrow mesenchymal stem cells (M-BMMSCs) induced by radiation were determined by immunofluorescence staining, CCK-8 cell proliferation assay, quantification of alkaline phosphatase (ALP) activity, alizarin red staining, and real-time RT-PCR, respectively. Moreover, the involvement of the RhoA/ROCK signaling pathway underlying this process was investigated via western blot analysis. We found that radiation induced significant damage to the cytoskeleton, cell viability, and osteogenic differentiation capacity of M-BMMSCs and downregulated their expression of RhoA, ROCK, and vinculin while increasing FAK expression. LIPUS treatment effectively rescued the disordered cytoskeleton and redistributed vinculin. Furthermore, the cell viability and osteogenic differentiation capacity were also significantly recovered. More importantly, it could reverse the aberrant expression of the key molecules induced by radiation. Inhibition of RhoA/ROCK signaling remarkably aggravated the inhibitory effect of radiation and attenuated the therapeutic effect of LIPUS. In the light of these findings, the RhoA/ROCK signaling pathway might be a promising target for modifying the therapeutic effect of LIPUS on osteoradionecrosis.


2013 ◽  
Vol 2013 ◽  
pp. 1-15 ◽  
Author(s):  
KiTaek Lim ◽  
Jangho Kim ◽  
Hoon Seonwoo ◽  
Soo Hyun Park ◽  
Pill-Hoon Choung ◽  
...  

Ultrasound stimulation produces significant multifunctional effects that are directly relevant to alveolar bone formation, which is necessary for periodontal healing and regeneration. We focused to find out effects of specific duty cycles and the percentage of time that ultrasound is being generated over one on/off pulse period, under ultrasound stimulation. Low-intensity pulsed ultrasound ((LIPUS) 1 MHz) with duty cycles of 20% and 50% was used in this study, and human alveolar bone-derived mesenchymal stem cells (hABMSCs) were treated with an intensity of 50 mW/cm2and exposure time of 10 min/day. hABMSCs exposed at duty cycles of 20% and 50% had similar cell viability (O.D.), which was higher (*P<0.05) than that of control cells. The alkaline phosphatase (ALP) was significantly enhanced at 1 week with LIPUS treatment in osteogenic cultures as compared to control. Gene expressions showed significantly higher expression levels of CD29, CD44, COL1, and OCN in the hABMSCs under LIPUS treatment when compared to control after two weeks of treatment. The effects were partially controlled by LIPUS treatment, indicating that modulation of osteogenesis in hABMSCs was related to the specific stimulation. Furthermore, mineralized nodule formation was markedly increased after LIPUS treatment than that seen in untreated cells. Through simple staining methods such as Alizarin red and von Kossa staining, calcium deposits generated their highest levels at about 3 weeks. These results suggest that LIPUS could enhance the cell viability and osteogenic differentiation of hABMSCs, and could be part of effective treatment methods for clinical applications.


2021 ◽  
Vol 6 (11) ◽  
pp. 4073-4082
Author(s):  
Kunzhan Cai ◽  
Yilai Jiao ◽  
Quan Quan ◽  
Yulin Hao ◽  
Jie Liu ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document