scholarly journals Evaluation of the SteamVR Motion Tracking System with a Custom-Made Tracker

2021 ◽  
Vol 11 (14) ◽  
pp. 6390
Author(s):  
Marcin Maciejewski

The paper presents the research of the SteamVR tracker developed for a man-portable air-defence training system. The tests were carried out in laboratory conditions, with the tracker placed on the launcher model along with elements ensuring the faithful reproduction of operational conditions. During the measurements, the static tracker was moved and rotated in a working area. The range of translations and rotations corresponded to the typical requirements of a shooting simulator application. The results containing the registered position and orientation values were plotted on 3D charts which showed the tracker’s operation. Further analyses determined the values of the systematic and random errors for measurements of the SteamVR system operating with a custom-made tracker. The obtained results with random errors of 0.15 mm and 0.008° for position and orientation, respectively, proved the high precision of the measurements.

Designs ◽  
2021 ◽  
Vol 5 (2) ◽  
pp. 30
Author(s):  
Verena Venek ◽  
Wolfgang Kremser ◽  
Thomas Stöggl

Many existing motion sensing applications in research, entertainment and exercise monitoring are based on the Microsoft Kinect and its skeleton tracking functionality. With the Kinect’s development and production halted, researchers and system designers are in need of a suitable replacement. We investigated the interchangeability of the discontinued Kinect v2 and the all-in-one, image-based motion tracking system Orbbec Persee for the use in an exercise monitoring system prototype called ILSE. Nine functional training exercises were performed by six healthy subjects in front of both systems simultaneously. Comparing the systems’ internal tracking states from ’not tracked’ to ‘tracked’ showed that the Persee system is more confident during motion sequences, while the Kinect is more confident for hip and trunk joint positions. Assessing the skeleton tracking robustness, the Persee’s tracking of body segment lengths was more consistent. Furthermore, we used both skeleton datasets as input for the ILSE exercise monitoring including posture recognition and repetition-counting. Persee data from exercises with lateral movement and in uncovered full-body frontal view provided the same results as Kinect data. The Persee further preferred tracking of quasi-static lower limb motions and tight-fitting clothes. With these limitations in mind, we find that the Orbbec Persee is a suitable replacement for the Microsoft Kinect for motion sensing within the ILSE exercise monitoring system.


Work ◽  
2021 ◽  
Vol 68 (s1) ◽  
pp. S209-S221
Author(s):  
Lu Han ◽  
Hechen Zhang ◽  
Zhongxia Xiang ◽  
Jinze Shang ◽  
Shabila Anjani ◽  
...  

BACKGROUND: The contrast between a bright computer screen and a dark ambient environment may influence comfort of the users, especially on their eyes. OBJECTIVE: The objective of this research is to identify the optimal desktop lighting for the comfortable use of the computer screen in a dark environment. METHODS: An experiment was designed where seven illumination setups were introduced for the users to perform their leisure tasks on a computer screen. Fifteen healthy subjects participated in the experiments. During each session, durations of the eye blinks, fixations and saccades of the user were recorded by an eye tracker. His/her neck and trunk movements were recorded by a motion tracking system as well. The comfort/discomfort questionnaire, localized postural discomfort questionnaire, NASA task load index and computer user questionnaire were used to record the overall comfort/discomfort, the local perceived physical discomfort, the cognitive workload, and general/eye health problems, respectively. RESULTS: Subjective and objective measurement results indicated that users felt more comfortable with high intensity warm lights using a computer screen. We also identified that the eye fixation durations, as well as the scores of two questions in the computer user questionnaire, have significant negative correlations with comfort. On the other side, the durations of blinks and the scores of three questions in the computer user questionnaire, were significantly correlated with discomfort. CONCLUSION: The warm (3000K) and high intensity (1500 lux) light reduced the visual and cognitive fatigue of the user and therefore improve the comfort of the user during the use of a computer screen.


2017 ◽  
Vol 14 (5) ◽  
pp. 172988141773275 ◽  
Author(s):  
Francisco J Perez-Grau ◽  
Fernando Caballero ◽  
Antidio Viguria ◽  
Anibal Ollero

This article presents an enhanced version of the Monte Carlo localization algorithm, commonly used for robot navigation in indoor environments, which is suitable for aerial robots moving in a three-dimentional environment and makes use of a combination of measurements from an Red,Green,Blue-Depth (RGB-D) sensor, distances to several radio-tags placed in the environment, and an inertial measurement unit. The approach is demonstrated with an unmanned aerial vehicle flying for 10 min indoors and validated with a very precise motion tracking system. The approach has been implemented using the robot operating system framework and works smoothly on a regular i7 computer, leaving plenty of computational capacity for other navigation tasks such as motion planning or control.


2008 ◽  
Author(s):  
Mohammed Goryawala ◽  
Misael Del Valle ◽  
Jiali Wang ◽  
James Byrne ◽  
Juan Franquiz ◽  
...  

2007 ◽  
Vol 12 (2) ◽  
pp. 91-104 ◽  
Author(s):  
Kenji Fushima ◽  
Masaru Kobayashi ◽  
Hiroaki Konishi ◽  
Kennichi Minagichi ◽  
Takeshi Fukuchi

2013 ◽  
Vol 694-697 ◽  
pp. 927-935 ◽  
Author(s):  
Yi Sun ◽  
Tao Ma ◽  
Chia Yung Han ◽  
Joseph Ross ◽  
William Wee

This paper presents a simple and accurate coordinate transformation method for extending the tracking space of the Intersense IS-900 spatial and motion tracking system using multiple pre-configured emitter towers to form the emitter constellation, but without resorting to the use of a surveyor machine. The proposed approach uses the differences of positional coordinate readings from each emitter tower among a set of commonly viewed spatial points to calculate the parameters needed to define the coordinate transformation. By applying this method, the tracking accuracy using the entire emitter constellation can be achieved by less than 0.5 inches error in most of the working space, and as low as 0.2 inches error in the frontal part of the working space.


Sign in / Sign up

Export Citation Format

Share Document