scholarly journals Cyclic Flexural and Shear Performances of Beam Elements with Longitudinal Glass Fiber Reinforced Polymer (GFRP) Bars in Exterior Beam-Column Connections

2018 ◽  
Vol 8 (12) ◽  
pp. 2353 ◽  
Author(s):  
Keun-Hyeok Yang ◽  
Ju-Hyun Mun

The objective of this study is to examine the effect of the poor anchorage length of glass fiber reinforced polymer (GFRP) bars used for longitudinal reinforcement on the flexural and shear performances of beam elements in exterior beam–column connections made using high-strength materials. Six exterior beam–column connection specimens were tested under reversal cyclic loads applied at the free-end of the beam. The selected strength categories of materials in the beam element were as follows: 35 MPa and 70 MPa for the design compressive strength of concrete, 400 MPa and 600 MPa for the yield strength of conventional longitudinal steel bars, and 800 MPa for the tensile strength of the GFRP bar. All the longitudinal steel bars of the beams satisfied the minimum requirements of the provisions of ACI 318–14, whereas all the longitudinal GFRP bars of the beam were linearly anchored into the column section, resulting in poor anchorage length, especially for the beam with the concrete compressive strength of 35 MPa. The flexure-governed beams with GFRP bars exhibited a greater increasing rate in displacement at the pre-peak state and did not display the plastic flow characteristic after the peak load when compared with companion beams with steel bars. The beams with GFRP bars possessed lower diagonal cracking strengths and shear capacities than the companion beams with steel bars although the shear capacities of the beams with GFRP bars could be conservatively predicted using the design equation of ACI 440.1R–15 provision. The low elastic modulus and elongation capacity of GFRP bars resulted in large displacements and brittle post-peak beam performances. Furthermore, the lack of anchorage length of GFRP bars in exterior beam–column connection significantly reduced the flexural strength and ductility of the beam element.

2018 ◽  
Vol 45 (6) ◽  
pp. 458-468 ◽  
Author(s):  
Brandon Fillmore ◽  
Pedram Sadeghian

Contribution of longitudinal glass fiber-reinforced polymer (GFRP) bars in concrete columns under compression has been ignored by current design guidelines. This paper challenges this convention by testing 21 concrete cylinders (150 mm × 300 mm) reinforced with longitudinal GFRP and steel bars in compression. It was observed that GFRP bars could sustain high level of compressive strains long after the peak load of the specimens without any premature crushing. The results of a new coupon test method showed that the elastic modulus of GFRP bars in compression is slightly higher than that of in tension, however the compressive strength was obtained 67% of tensile strength. An analytical model was successfully implemented to predict the axial capacity of the tests specimens and it was found that the contribution of the bars in the load capacity of the specimens was within 4.5–18.4% proportional to the bars reinforcement ratio normalized to the elastic modulus of steel bars.


2011 ◽  
Vol 71-78 ◽  
pp. 1711-1714
Author(s):  
Li Sun ◽  
Xiang Qian Mi ◽  
Xin Shou Zhang

Glass fiber reinforced polymer (GFRP) bars were exposed to the solutions of different alkaline and chloride salt concentrations in order to examine the influence of different corrosion environment on the compression performance of GFRP bars. The results showed that the stress strain curves of the GFRP bars could be expressed as lines approximately. The compressive strength and elastic modulus gradually decreased with increasing of the corrosion time, and the decrease was more obvious in alkaline corrosion environment.


2014 ◽  
Vol 1015 ◽  
pp. 211-214
Author(s):  
Hai Shuang Liu ◽  
Ke Zhao ◽  
Ze Liu

Several kinds of Glass Fiber Reinforced Polymer (GFRP) bars with different winding materials were manufactured through modifying the production process. Based on the experiments, compression and bending properties were tested. Through the observation of experiment phenomenon and the analysis of test date, the influence and mechanism from different winding materials are discussed. The test results that winding materials affect the compressive strength and bending strength of GFRP bars to a certain extent.


2021 ◽  
Vol 68 (1) ◽  
Author(s):  
Mohamed S. Moawad ◽  
Ahmed Fawzi

AbstractOne of the major advantages of using glass fiber-reinforced polymer bars as a replacement to the traditional steel-reinforced bars is its lightweight and high-resistant to corrosion. This research focuses on the performance of concrete beams partially/fully reinforced with glass fiber-reinforced polymer bars with 50% of GFRP bars were used to reinforce partially concrete beams at flexural zone. While 100% of GFRP bars were used to reinforce fully concrete beams at flexural and compression zones with different concrete compressive strength.This study reported the test results of 6 reinforced concrete beams with dimensions 150 × 200mm and a 1700-mm clear span length subjected to a four-point loading system. The tested beams were divided into three groups; the first one refers to the glass fiber-reinforced polymer bar effect. The second group is referring to the effect of concrete compressive strength, while the third group is referring to the effect of the GFRP bar volume ratio.Using longitudinal GFRP bars as a full or partial replacement of longitudinal steel bar reinforcement led to an increase in the failure load capacity and the average crack width, while a decrease in ductility was reported with a lower number of cracks. Increasing the concrete compressive strength is more compatible with GFRP bar reinforcement and enhanced the failure performance of beams compared with normal compressive strength concrete.


Author(s):  
Iurii Burda ◽  
Michel Barbezat ◽  
Andreas J Brunner

Glass-fiber reinforced polymer (GFRP) composite rods with epoxy matrix filled with electrically nonconducting particles find widespread use in high-voltage electrical insulator applications. The service loads require a range of different, minimum material property values, e.g. toughness, tensile, or compressive strength, but also component-specific performance, e.g. pull-out friction of surface crimped metal fittings or electric breakdown strength. The contribution discusses selected examples of the effects of different particle filler types on the properties of filled epoxy resin as well as on the behavior of GFRP rods with such a matrix. In all investigated systems CaCO3 was used as micron-sized filler, complemented by different amounts of either nanosilica or core-shell rubber (binary filler), or by both, nanosilica and core-shell rubber (ternary filler). With ternary filler combinations at a content of 36 wt%, fracture toughness GIC was improved in nanocomposite epoxy plates and in GFRP rods by 60% and 100%, respectively compared to a matrix with 20 wt% CaCO3 (used as reference system). The glass transition temperature Tg for some ternary systems dropped from 160 °C (for neat epoxy), to approximately 140 °C, the maximum allowed drop in Tg in view of requirements from further processing steps of the electrically insulating components. The ternary fillers yield transfer of the improvements of fracture properties from epoxy nanocomposite plates into the GFRP rods beyond that of the system with CaCO3 filler only. Compressive strength of the GFRP rods was improved by about 20% only for the binary nanosilica and CaCO3 filler, and was not significantly enhanced with the ternary systems. That combination, however, did not yield improvements in toughness beyond the CaCO3-filled nanocomposite plates and rods. With the range of filler types and contents investigated here, it was hence not possible to simultaneously optimize both, fracture toughness and compressive strength of the GFRP insulator rods.


2007 ◽  
Vol 345-346 ◽  
pp. 1217-1220
Author(s):  
Jung Yoon Lee

The use of fiber reinforced polymer (FRP) bars has been gaining increasing popularity in the civil engineering community due to their favorable properties such as high-strength-to-weight ratio and good corrosion resistance. In order for concrete to be FRP reinforced, there must be interfacial bond between FRP bars and concrete. The interfacial bond behavior of FRP bars to concrete is expected to vary from that of conventional steel bars, since various key parameters that influence bond performance are different. This paper presents the results of an experimental and analytical study on the interfacial surface interaction of glass fiber reinforced polymer (GFRP) bars in high strength concrete cube. The experimental program consisted of testing 54 concrete cubes prepared according to CSA S802-02 standard 1). The split specimens showed that interfacial bond failure of the steel bar occurred due to concrete crushing in front of the bar deformations, while interfacial bond failure of the GFRP bars occurred partly on the surface of the bar and partly in the concrete by peeling of the surface layer of the bar.


2021 ◽  
Vol 9 (1) ◽  
pp. 72-78
Author(s):  
Osama Daoud ◽  
Ahmed Fadul

The behavior and shear strength of concrete beams reinforced with glass fiber-reinforced polymer (GFRP) bars was investigated. Total of six reinforced concrete beams without stirrups were constructed and tested up to failure. The beams measured 1400 mm long, 150 mm wide and 300 mm deep and were tested in two-points bending with constant shear span 350 mm in all tested beams, and shear span to depth ratio a/d 1.37. The test variable was the reinforcement ratio. The test beams included three beams designed as tension control (T.C) with GFRP bars, three beams designed as compression control (C.C) with GFRP bars. The test results were compared with predictions provided by ACI 440.1R-15 design guideline and proposed equations in the literature. The test results indicated that the relatively low modulus of elasticity of FRP bars resulted in reducing shear strength. In addition, shear strength provided by ACI 440.1R-15 guideline underestimate shear strength capacity in which proposed equations in the literature had given better prediction than ACI 440.1R-15. The failure mode in T.C beams is diagonal tension by bond failure not by rupture of FRP and C.C beams is shear compression by crushing of the web in extreme fiber.  