scholarly journals Advanced Sandwich Composite Cores for Patient Support in Advanced Clinical Imaging and Oncology Treatment

Materials ◽  
2020 ◽  
Vol 13 (16) ◽  
pp. 3549
Author(s):  
Robert H. Morris ◽  
Nicasio R. Geraldi ◽  
Lucy C. Pike ◽  
Jörg Pawelke ◽  
Aswin L. Hoffmann ◽  
...  

Ongoing advances in both imaging and treatment for oncology purposes have seen a significant rise in the use of not only the individual imaging modalities, but also their combination in single systems such as Positron Emission Tomography combined with Computed Tomography (PET–CT) and PET–MRI (Magnetic Resonance Imaging) when planning for advanced oncology treatment, the most demanding of which is proton therapy. This has identified issues in the availability of suitable materials upon which to support the patient undergoing imaging and treatment owing to the differing requirements for each of the techniques. Sandwich composites are often selected to solve this issue but there is little information regarding optimum materials for their cores. In this paper, we presented a range of materials which are suitable for such purposes and evaluated the performance for use in terms of PET signal attenuation, proton beam stopping, MRI signal shading and X-Ray CT visibility. We found that Extruded Polystyrene offers the best compromise for patient support and positioning structures across all modalities tested, allowing for significant savings in treatment planning time and delivering more efficient treatment with lower margins.

2019 ◽  
Vol 187 (4) ◽  
pp. 535-539
Author(s):  
Woon-Kwan Chung ◽  
Nam-Hee Yang ◽  
Kyung-Rae Dong ◽  
Jiwon Choi

Abstract This study aimed to set a dose constraint for certain duties of radiological technologists in the department of nuclear medicine. From 2013 to 2017, the 5 y radiation exposure data of employees performing PET-CT and γ-CAMERA of eight hospitals in Korea were measured individual exposure doses to estimate the frequency and set a representative dose of 75 and 95% from the low dose in the whole category is presented. The dose constraint was 5.5 mSv for PET-CT, 4.5 mSv for γ-CAMERA and 3.5 mSv for Positron Emission Tomography (PET)-Computed Tomography(CT) and Gamma CAMERA (γ-CAMERA). Therefore, it would be appropriate to set a dose-limit value of ~5 mSv corresponding to 75–80% of the individual exposure dose of radiological technologists in the department of nuclear medicine. The finding of this study may be used as reference data for setting future radiation dose limits.


2005 ◽  
Vol 44 (S 01) ◽  
pp. S46-S50 ◽  
Author(s):  
M. Dawood ◽  
N. Lang ◽  
F. Büther ◽  
M. Schäfers ◽  
O. Schober ◽  
...  

Summary:Motion in PET/CT leads to artifacts in the reconstructed PET images due to the different acquisition times of positron emission tomography and computed tomography. The effect of motion on cardiac PET/CT images is evaluated in this study and a novel approach for motion correction based on optical flow methods is outlined. The Lukas-Kanade optical flow algorithm is used to calculate the motion vector field on both simulated phantom data as well as measured human PET data. The motion of the myocardium is corrected by non-linear registration techniques and results are compared to uncorrected images.


2011 ◽  
Vol 14 (5) ◽  
pp. 283 ◽  
Author(s):  
Andre Plass ◽  
Maximilian Y. Emmert ◽  
Oliver Gaemperli ◽  
Hatem Alkadhi ◽  
Philipp Kaufmann ◽  
...  

<p><b>Background:</b> We evaluated how comprehensive assessment of coronary artery lesions and their hemodynamic relevance by means of hybrid positron emission tomography (PET) and computed tomography (CT) imaging would affect decision-making in coronary artery bypass surgery (CABG), compared with using invasive coronary angiography (ICA) alone.</p><p><b>Methods:</b> After undergoing ICA, 27 patients (21 men and 6 women; mean SD age, 66 � 10 years) planned for cardiac surgery were scheduled for myocardial perfusion stress/rest evaluation with [13N]ammonia PET and CT coronary angiography. Only ICA was available to the surgeon. Postoperatively, the performed CABG was compared with the hypothetical strategy based on hybrid PET/CT findings (regional coronary flow reserve [CFR], myocardial perfusion defects). Procedures included CABG (n = 18) alone, CABG combined with valve replacement (n = 6), and CABG combined with isolated valve replacement (n = 3). A total of 56 bypass grafts (28 venous and 28 arterial) and 66 distal anastomoses were placed.</p><p><b>Results:</b> CT evaluation showed 93% concordance (66/71) with ICA regarding significant stenoses, with sensitivity, specificity, positive predictive value, and negative predictive value of 93.1%, 98.7%, 94.4%, and 98.4%, respectively. In the PET scan, 16 patients had 1 ischemic region, and 12 patients had 1 scar region, including 5 patients who presented with mixed conditions (scar and ischemia). One patient had a completely normal myocardium. Compared with the performed surgery, PET/CT fusion evaluation showed that of the performed anastomoses, 48% had documented ischemia (with a CFR <2 in 86%), 38% were nonischemic (although a CFR value <2 was found in 78%), and 14% had scar tissue (fixed perfusion defect).</p><p><b>Conclusions:</b> Although <50% of bypasses were placed to areas with myocardial ischemia, the CFR was low in the majority of nonischemic regions, a finding that may have important prognostic relevance. PET/CT fusion imaging could potentially influence planning for CABG and provide incremental prognostic information.</p>


Author(s):  
Marco Tana ◽  
Silvio di Carlo ◽  
Marcello Romano ◽  
Massimo Alessandri ◽  
Cosima Schiavone ◽  
...  

Background:18F-fluorodeoxyglucose positron emission tomography integrated with computed tomography (18-F-FDG-PET/CT) is getting wide consensus in the diagnosis and staging of neoplastic disorders and represents a useful tool in the assessment of various inflammatory conditions. </P><P> Discussion: Sarcoidosis is an uncommon disease characterized by the systemic formation of noncaseating granulomas. Lungs are the sites most often affected, and investigation with high resolution computed tomography and biopsy is essential to achieve a correct diagnosis. 18-F-FDGPET/ CT is effective in the assessment of pulmonary sarcoidosis by demonstrating pulmonary and extrathoracic involvement and findings correlate well with pulmonary function in patients affected.Conclusion:This review would illustrate the usefulness and limits of 18-F-FDG-PET/CT in the assessment of pulmonary sarcoidosis.


2019 ◽  
Vol 12 (3) ◽  
pp. 220-228 ◽  
Author(s):  
Laura Evangelista ◽  
Lea Cuppari ◽  
Luisa Bellu ◽  
Daniele Bertin ◽  
Mario Caccese ◽  
...  

Purpose: The aims of the present study were to: 1- critically assess the utility of L-3,4- dihydroxy-6-18Ffluoro-phenyl-alanine (18F-DOPA) and O-(2-18F-fluoroethyl)-L-tyrosine (18F-FET) Positron Emission Tomography (PET)/Computed Tomography (CT) in patients with high grade glioma (HGG) and 2- describe the results of 18F-DOPA and 18F-FET PET/CT in a case series of patients with recurrent HGG. Methods: We searched for studies using the following databases: PubMed, Web of Science and Scopus. The search terms were: glioma OR brain neoplasm and DOPA OR DOPA PET OR DOPA PET/CT and FET OR FET PET OR FET PET/CT. From a mono-institutional database, we retrospectively analyzed the 18F-DOPA and 18F-FET PET/CT of 29 patients (age: 56 ± 12 years) with suspicious for recurrent HGG. All patients underwent 18F-DOPA or 18F-FET PET/CT for a multidisciplinary decision. The final definition of recurrence was made by magnetic resonance imaging (MRI) and/or multidisciplinary decision, mainly based on the clinical data. Results: Fifty-one articles were found, of which 49 were discarded, therefore 2 studies were finally selected. In both the studies, 18F-DOPA and 18F-FET as exchangeable in clinical practice particularly for HGG patients. From our institutional experience, in 29 patients, we found that sensitivity, specificity and accuracy of 18F-DOPA PET/CT in HGG were 100% (95% confidence interval- 95%CI - 81-100%), 63% (95%CI: 39-82%) and 62% (95%CI: 39-81%), respectively. 18F-FET PET/CT was true positive in 4 and true negative in 4 patients. Sensitivity, specificity and accuracy for 18F-FET PET/CT in HGG were 100%. Conclusion: 18F-DOPA and 18F-FET PET/CT have a similar diagnostic accuracy in patients with recurrent HGG. However, 18F-DOPA PET/CT could be affected by inflammation conditions (false positive) that can alter the final results. Large comparative trials are warranted in order to better understand the utility of 18F-DOPA or 18F-FET PET/CT in patients with HGG.


Author(s):  
Jonny Nordström ◽  
Hendrik J. Harms ◽  
Tanja Kero ◽  
Jens Sörensen ◽  
Mark Lubberink

Abstract Background Patient motion is a common problem during cardiac PET. The purpose of the present study was to investigate to what extent motions influence the quantitative accuracy of cardiac 15O-water PET/CT and to develop a method for automated motion detection. Method Frequency and magnitude of motion was assessed visually using data from 50 clinical 15O-water PET/CT scans. Simulations of 4 types of motions with amplitude of 5 to 20 mm were performed based on data from 10 scans. An automated motion detection algorithm was evaluated on clinical and simulated motion data. MBF and PTF of all simulated scans were compared to the original scan used as reference. Results Patient motion was detected in 68% of clinical cases by visual inspection. All observed motions were small with amplitudes less than half the LV wall thickness. A clear pattern of motion influence was seen in the simulations with a decrease of myocardial blood flow (MBF) in the region of myocardium to where the motion was directed. The perfusable tissue fraction (PTF) trended in the opposite direction. Global absolute average deviation of MBF was 3.1% ± 1.8% and 7.3% ± 6.3% for motions with maximum amplitudes of 5 and 20 mm, respectively. Automated motion detection showed a sensitivity of 90% for simulated motions ≥ 10 mm but struggled with the smaller (≤ 5 mm) simulated (sensitivity 45%) and clinical motions (accuracy 48%). Conclusion Patient motion can impair the quantitative accuracy of MBF. However, at typically occurring levels of patient motion, effects are similar to or only slightly larger than inter-observer variability, and downstream clinical effects are likely negligible.


Diagnostics ◽  
2021 ◽  
Vol 11 (8) ◽  
pp. 1421
Author(s):  
Babak Saboury ◽  
Lars Edenbrandt ◽  
Reza Piri ◽  
Oke Gerke ◽  
Tom Werner ◽  
...  

Multislice cardiac CT characterizes late stage macrocalcification in epicardial arteries as opposed to PET/CT, which mirrors early phase arterial wall changes in epicardial and transmural coronary arteries. With regard to tracer, there has been a shift from using mainly 18F-fluorodeoxyglucose (FDG), indicating inflammation, to applying predominantly 18F-sodium fluoride (NaF) due to its high affinity for arterial wall microcalcification and more consistent association with cardiovascular risk factors. To make NaF-PET/CT an indispensable adjunct to clinical assessment of cardiac atherosclerosis, the Alavi–Carlsen Calcification Score (ACCS) has been proposed. It constitutes a global assessment of cardiac atherosclerosis burden in the individual patient, supported by an artificial intelligence (AI)-based approach for fast observer-independent segmentation. Common measures for characterizing epicardial coronary atherosclerosis by NaF-PET/CT as the maximum standardized uptake value (SUV) or target-to-background ratio are more versatile, error prone, and less reproducible than the ACCS, which equals the average cardiac SUV. The AI-based approach ensures a quick and easy delineation of the entire heart in 3D to obtain the ACCS expressing ongoing global cardiac atherosclerosis, even before it gives rise to CT-detectable coronary calcification. The quantification of global cardiac atherosclerotic burden by the ACCS is suited for management triage and monitoring of disease progression with and without intervention.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Philip E. Schaner ◽  
Ly-Binh-An Tran ◽  
Bassem I. Zaki ◽  
Harold M. Swartz ◽  
Eugene Demidenko ◽  
...  

AbstractDuring a first-in-humans clinical trial investigating electron paramagnetic resonance tumor oximetry, a patient injected with the particulate oxygen sensor Printex ink was found to have unexpected fluorodeoxyglucose (FDG) uptake in a dermal nodule via positron emission tomography (PET). This nodule co-localized with the Printex ink injection; biopsy of the area, due to concern for malignancy, revealed findings consistent with ink and an associated inflammatory reaction. Investigations were subsequently performed to assess the impact of oxygen sensors on FDG-PET/CT imaging. A retrospective analysis of three clinical tumor oximetry trials involving two oxygen sensors (charcoal particulates and LiNc-BuO microcrystals) in 22 patients was performed to evaluate FDG imaging characteristics. The impact of clinically used oxygen sensors (carbon black, charcoal particulates, LiNc-BuO microcrystals) on FDG-PET/CT imaging after implantation in rat muscle (n = 12) was investigated. The retrospective review revealed no other patients with FDG avidity associated with particulate sensors. The preclinical investigation found no injected oxygen sensor whose mean standard uptake values differed significantly from sham injections. The risk of a false-positive FDG-PET/CT scan due to oxygen sensors appears low. However, in the right clinical context the potential exists that an associated inflammatory reaction may confound interpretation.