scholarly journals Novel Design and Finite Element Analysis of Diamond-like Porous Implants with Low Stiffness

Materials ◽  
2021 ◽  
Vol 14 (22) ◽  
pp. 6918
Author(s):  
Jinyang Zhang ◽  
Xiao Zhang ◽  
Yang Chen ◽  
Wei Feng ◽  
Xianshuai Chen

The purpose of this study was to design porous implants with low stiffness and evaluate their biomechanical behavior. Thus, two types of porous implants were designed (Type I: a combined structure of diamond-like porous scaffold and traditional tapered thread. Type II: a cylindrical porous scaffold filled by arrayed basic diamond-like pore units). Three implant-supported prosthesis models were constructed from Type I, Type II and commercial implants (control group) and were evaluated by finite element analysis (FEA). The stress distribution pattern of the porous implants were assessed and compared with the control group. In addition, the stiffness of the cylindrical specimens simplified from three types of implants was calculated. The Type I implant exhibited better stress distribution than the Type II implant. The maximum stress between the cortical bone–Type I implant interface was 12.9 and 19.0% lower than the other two groups. The peak stress at the cancellous bone–Type I implant interface was also reduced by 16.8 and 38.7%. Compared with the solid cylinder, the stiffness of diamond-like pore cylinders simplified from the two porous implants geometry was reduced by 61.5 to 76.1%. This construction method of porous implant can effectively lower its stiffness and optimize the stress distribution at the implant–bone interface.

2019 ◽  
Vol 45 (5) ◽  
pp. 363-370
Author(s):  
Gokce Soganci Unsal ◽  
Guzin Neda Hasanoglu Erbasar ◽  
Filiz Aykent ◽  
Ozgun Yusuf Ozyilmaz ◽  
Mahmut Sertac Ozdogan

The biomechanical behavior of the edentulous mandible with bone irregularities that has been rehabilitated with implant-supported overdentures has become an important factor for treatment planning. Restorative options, including dental implants with various attachments, affect the stress distribution. The purpose of this study was to evaluate the stress distribution of cortical bone around the implant neck and implant structures in overdentures with two different attachment types at the edentulous mandible and with different bone heights using three-dimensional finite element analysis. Five three-dimensional models of an edentulous mandible were designed and implemented. Ten models were constructed with ball and locator attachments. Static bilateral and unilateral vertical and oblique occlusal loads with magnitudes of 100 N were applied to the overdentures. The principal stresses were higher in the presence of oblique loads compared to vertical loads in all the analyzed models. Maximum principal stresses were observed around the mesial side of the contralateral implant, and the minimum principal stresses were noted around the distal side of ipsilateral implant during unilateral vertical loading. These patterns were reversed during oblique loadings. The ball attachment models yielded lower von Mises stress values than the locator models at all the loading conditions, while the stress distributions were similar in the models with the same and different bone levels. Correspondingly, bone corrections due to irregularities may not be necessary in terms of biomechanics. The results of this study may provide clinicians a better understanding for the mandibular overdenture design in the cases at which different bone heights exist.


2015 ◽  
Vol 40 (4) ◽  
pp. E158-E166 ◽  
Author(s):  
ACO Souza ◽  
TA Xavier ◽  
JA Platt ◽  
ALS Borges

SUMMARY The purpose of this study was to evaluate the influence of direct base and indirect inlay materials on stress distribution and fracture resistance of endodontically treated premolars with weakened cusps. Forty healthy human premolars were selected; five were left intact as controls (group C+), and the others were subjected to endodontic treatment and removal of buccal and lingual cusp dentin. Five teeth were left as negative controls (group C−). The remaining 30 teeth were divided into two groups according to the direct base material (glass ionomer [GIC] or composite resin [CR]). After base placement, each group was subjected to extensive inlay preparation, and then three subgroups were created (n=5): no inlay restoration (GIC and CR), restored with an indirect composite resin inlay (GIC+IR and CR+IR), and restored with a ceramic inlay (GIC+C and CR+C). Each specimen was loaded until fracture in a universal testing machine. For finite element analysis, the results showed that the removal of tooth structure significantly affected fracture resistance. The lowest values were presented by the negative control group, followed by the restored and based groups (not statistically different from each other) and all lower than the positive control group. In finite element analysis, the stress concentration was lower in the restored tooth compared to the tooth without restoration, whereas in the restored teeth, the stress concentration was similar, regardless of the material used for the base or restoration. It can be concluded that the inlay materials combined with a base showed similar behavior and were not able to regain the strength of intact tooth structure.


2020 ◽  
Vol 1 (1) ◽  
pp. 11761
Author(s):  
Felipe De Souza Matos ◽  
Thaís Christina Cunha ◽  
Ayla Macyelle De Oliveira Correia ◽  
João Paulo Mendes Tribst ◽  
Taciana Marco Ferraz Caneppele ◽  
...  

The aim of this study was to investigate, through finite element analysis, the impact of different restorative techniques on stress distribution in endodontically-treated maxillary first premolars. A human maxillary first premolar was modeled following the real anatomical dimensions, through a periapical radiography, using the Rhinoceros software, version 4.0SR8. The model was then replicated to compose the groups according to the coronary restorative technique: C (coltosol), GI.C (glass ionomer + coltosol), GI (glass ionomer), CR.GI (conventional resin + glass ionomer), and BR.GI (Bulk Fill resin + glass ionomer). After the models were finished, they were imported as IGES files into ANSYS software, version 17.2. Fixation was defined at the base of the cortical bone and the load was applied with 300 N axially to the buccal and palatal cusps. The results generated were in maximum principal stress (MPS), with the CR.GI and BR.GI groups presenting the lowest values of tension concentration and more homogeneous stress distribution, followed by GI, GI.C and C. All restorative techniques affected the stress distribution in endodontically-treated maxillary first premolars, promoting greater tension in the occlusal third, at the interface with the buccal wall, and in the cervical third. Conventional or Bulk Fill resins associated with a glass ionomer base have a superior biomechanical behavior in relation to coltosol or glass ionomer.


2013 ◽  
Vol 39 (5) ◽  
pp. 575-581 ◽  
Author(s):  
Mateus Bertolini Fernandes dos Santos ◽  
Rafael Leonardo Xediek Consani ◽  
Marcelo Ferraz Mesquita

The aim of this study was to evaluate the stress distribution in the bone adjacent to submerged implants during masticatory function in conventional complete dentures with different soft liners through finite element analysis. Three-dimensional models of a severely resorbed mandible with 2 and 4 submerged implants in the anterior region were created and divided into the following situations: (1) conventional complete dentures (control group); and conventional complete dentures with different soft liner materials, (2) Coe-Comfort, (3) Softliner, and (4) Molteno Hard. The models were exported to mechanical simulation software and 2 simulations were done with the load in the inferior right canine (35 N) and the inferior right first molar (50 N). The data were qualitatively evaluated using the maximum principal stress and microstrain values given by the software. The use of soft liners provides decreased levels of stress and microstrains in peri-implant bone when the load was applied to canine teeth. Considering all of the values obtained in this study, the use of softer materials is the most suitable for use during the period of osseointegration.


2021 ◽  
Vol 11 (3) ◽  
pp. 1220
Author(s):  
Azeem Ul Yaqin Syed ◽  
Dinesh Rokaya ◽  
Shirin Shahrbaf ◽  
Nicolas Martin

The effect of a restored machined hybrid dental ceramic crown–tooth complex is not well understood. This study was conducted to determine the effect of the stress state of the machined hybrid dental ceramic crown using three-dimensional finite element analysis. Human premolars were prepared to receive full coverage crowns and restored with machined hybrid dental ceramic crowns using the resin cement. Then, the teeth were digitized using micro-computed tomography and the teeth were scanned with an optical intraoral scanner using an intraoral scanner. Three-dimensional digital models were generated using an interactive image processing software for the restored tooth complex. The generated models were imported into a finite element analysis software with all degrees of freedom concentrated on the outer surface of the root of the crown–tooth complex. To simulate average occlusal load subjected on a premolar a total load of 300 N was applied, 150 N at a buccal incline of the palatal cusp, and palatal incline of the buccal cusp. The von Mises stresses were calculated for the crown–tooth complex under simulated load application was determined. Three-dimensional finite element analysis showed that the stress distribution was more in the dentine and least in the cement. For the cement layer, the stresses were more concentrated on the buccal cusp tip. In dentine, stress was more on the cusp tips and coronal 1/3 of the root surface. The conventional crown preparation is a suitable option for machined polymer crowns with less stress distribution within the crown–tooth complex and can be a good aesthetic replacement in the posterior region. Enamic crowns are a good viable option in the posterior region.


Sensors ◽  
2021 ◽  
Vol 21 (5) ◽  
pp. 1654
Author(s):  
Poojitha Vurtur Badarinath ◽  
Maria Chierichetti ◽  
Fatemeh Davoudi Kakhki

Current maintenance intervals of mechanical systems are scheduled a priori based on the life of the system, resulting in expensive maintenance scheduling, and often undermining the safety of passengers. Going forward, the actual usage of a vehicle will be used to predict stresses in its structure, and therefore, to define a specific maintenance scheduling. Machine learning (ML) algorithms can be used to map a reduced set of data coming from real-time measurements of a structure into a detailed/high-fidelity finite element analysis (FEA) model of the same system. As a result, the FEA-based ML approach will directly estimate the stress distribution over the entire system during operations, thus improving the ability to define ad-hoc, safe, and efficient maintenance procedures. The paper initially presents a review of the current state-of-the-art of ML methods applied to finite elements. A surrogate finite element approach based on ML algorithms is also proposed to estimate the time-varying response of a one-dimensional beam. Several ML regression models, such as decision trees and artificial neural networks, have been developed, and their performance is compared for direct estimation of the stress distribution over a beam structure. The surrogate finite element models based on ML algorithms are able to estimate the response of the beam accurately, with artificial neural networks providing more accurate results.