scholarly journals Membrane-Based Microwave-Mediated Electrochemical Immunoassay for the In Vitro, Highly Sensitive Detection of Osteoporosis-Related Biomarkers

Sensors ◽  
2018 ◽  
Vol 18 (9) ◽  
pp. 2933 ◽  
Author(s):  
Hye Kim ◽  
Shinobu Sato ◽  
Shigeori Takenaka ◽  
Min-Ho Lee

Highly sensitive and multiplexed in vitro detection of osteoporosis-related biochemical markers were carried out based on the membrane-based microwave-mediated electrochemical immunoassay (MMeEIA), where we can dramatically reduce the sample preparation time by shortening the incubation time of conjugation to obtain sensitive detection based on three dimensional conjugation of antibodies with target antigens in nylon membrane disk. C-terminal cross-linked telopeptide of type I collagen (CTx), Osteocalcin (OC), parathyroid hormone (PTH), and N-terminal propeptide of type I collagen (P1NP), which can be utilized to monitor the progress of osteoporosis, were quantified using their corresponding antibody immobilized in membranes. Coefficient of variations in this intra- and inter-assays were within 8.0% for all markers. When compared with data obtained from clinically used standard equipment (Roche modular E170), their coefficients of determination, R2 values, are mostly more than 0.9. They show that the results obtained from MMeEIA are in good agreement with that from the conventional clinical instruments.

Author(s):  
Lowell T. Edgar ◽  
Steve A. Maas ◽  
James E. Guilkey ◽  
Jeffrey A. Weiss

Recent developments in tissue engineering have created demand for the ability to create microvascular networks with specific topologies in vitro. During angiogenesis, sprouting endothelial cells apply traction forces and migrate along components of the extracellular matrix (ECM), resulting in neovessel elongation [1]. The fibrillar structure of the ECM serves as the major pathway for mechanotransduction between contact-dependent cells. Using a three-dimensional (3D) organ culture model of microvessel fragments within a type-I collagen gel, we have shown that subjecting the culture to different boundary conditions during angiogenesis can lead to drastically different vascular topologies [2]. Fragments cultured in a rectangular gel that were free to contract grew into a randomly oriented network [3, 4]. When the long-axis of the gel was constrained as to prevent contraction, microvessels and collagen fibers were found aligned along the constrained axis (Fig. 1) [4].


2009 ◽  
Vol 131 (10) ◽  
Author(s):  
Jinjin Ma ◽  
Kristen Goble ◽  
Michael Smietana ◽  
Tatiana Kostrominova ◽  
Lisa Larkin ◽  
...  

The incidence of ligament injury has recently been estimated at 400,000/year. The preferred treatment is reconstruction using an allograft, but outcomes are limited by donor availability, biomechanical incompatibility, and immune rejection. The creation of an engineered ligament in vitro solely from patient bone marrow stromal cells (has the potential to greatly enhance outcomes in knee reconstructions. Our laboratory has developed a scaffoldless method to engineer three-dimensional (3D) ligament and bone constructs from rat bone marrow stem cells in vitro. Coculture of these two engineered constructs results in a 3D bone-ligament-bone (BLB) construct with viable entheses, which was successfully used for medial collateral ligament (MCL) replacement in a rat model. 1 month and 2 month implantations were applied to the engineered BLBs. Implantation of 3D BLBs in a MCL replacement application demonstrated that our in vitro engineered tissues grew and remodeled quickly in vivo to an advanced phenotype and partially restored function of the knee. The explanted 3D BLB ligament region stained positively for type I collagen and elastin and was well vascularized after 1 and 2 months in vivo. Tangent moduli of the ligament portion of the 3D BLB 1 month explants increased by a factor of 2.4 over in vitro controls, to a value equivalent to those observed in 14-day-old neonatal rat MCLs. The 3D BLB 1 month explants also exhibited a functionally graded response that closely matched native MCL inhomogeneity, indicating the constructs functionally adapted in vivo.


2004 ◽  
Vol 167 (4) ◽  
pp. 757-767 ◽  
Author(s):  
Tae-Hwa Chun ◽  
Farideh Sabeh ◽  
Ichiro Ota ◽  
Hedwig Murphy ◽  
Kevin T. McDonagh ◽  
...  

During angiogenesis, endothelial cells initiate a tissue-invasive program within an interstitial matrix comprised largely of type I collagen. Extracellular matrix–degradative enzymes, including the matrix metalloproteinases (MMPs) MMP-2 and MMP-9, are thought to play key roles in angiogenesis by binding to docking sites on the cell surface after activation by plasmin- and/or membrane-type (MT) 1-MMP–dependent processes. To identify proteinases critical to neovessel formation, an ex vivo model of angiogenesis has been established wherein tissue explants from gene-targeted mice are embedded within a three-dimensional, type I collagen matrix. Unexpectedly, neither MMP-2, MMP-9, their cognate cell-surface receptors (i.e., β3 integrin and CD44), nor plasminogen are essential for collagenolytic activity, endothelial cell invasion, or neovessel formation. Instead, the membrane-anchored MMP, MT1-MMP, confers endothelial cells with the ability to express invasive and tubulogenic activity in a collagen-rich milieu, in vitro or in vivo, where it plays an indispensable role in driving neovessel formation.


2013 ◽  
Vol 2013 ◽  
pp. 1-6 ◽  
Author(s):  
Po Chun Chen ◽  
Sheng Jen Hsieh ◽  
Chien Chon Chen ◽  
Jun Zou

We proposed fabricating an aluminum microneedle array with a nanochannel structure on the surface by combining micromachining, electrolyte polishing, and anodization methods. The microneedle array provides a three-dimensional (3D) structure that possesses several hundred times more surface area than a traditional nanochannel template. Therefore, the microneedle array can potentially be used in many technology applications. This 3D microneedle array device can not only be used for painless injection or extraction, but also for storage, highly sensitive detection, drug delivery, and microelectrodes. From the calculation we made, the microneedle array not only increases surface area, but also enlarges the capacity of the device. Therefore, the microneedle array can further be used on many detecting, storing, or drug delivering applications.


Cartilage ◽  
2021 ◽  
pp. 194760352110495
Author(s):  
Xue Dong ◽  
Ishani D. Premaratne ◽  
Jaime L. Bernstein ◽  
Arash Samadi ◽  
Alexandra J. Lin ◽  
...  

Objective: A major obstacle in the clinical translation of engineered auricular scaffolds is the significant contraction and loss of topography that occur during maturation of the soft collagen-chondrocyte matrix into elastic cartilage. We hypothesized that 3-dimensional-printed, biocompatible scaffolds would “protect” maturing hydrogel constructs from contraction and loss of topography. Design: External disc-shaped and “ridged” scaffolds were designed and 3D-printed using polylactic acid (PLA). Acellular type I collagen constructs were cultured in vitro for up to 3 months. Collagen constructs seeded with bovine auricular chondrocytes (BAuCs) were prepared in 3 groups and implanted subcutaneously in vivo for 3 months: preformed discs with (“Scaffolded/S”) or without (“Naked/N”) an external scaffold and discs that were formed within an external scaffold via injection molding (“Injection Molded/SInj”). Results: The presence of an external scaffold or use of injection molding methodology did not affect the acellular construct volume or base area loss. In vivo, the presence of an external scaffold significantly improved preservation of volume and base area at 3 months compared to the naked group ( P < 0.05). Construct contraction was mitigated even further in the injection molded group, and topography of the ridged constructs was maintained with greater fidelity ( P < 0.05). Histology verified the development of mature auricular cartilage in the constructs within external scaffolds after 3 months. Conclusion: Custom-designed, 3D-printed, biocompatible external scaffolds significantly mitigate BAuC-seeded construct contraction and maintain complex topography. Further refinement and scaling of this approach in conjunction with construct fabrication utilizing injection molding may aid in the development of full-scale auricular scaffolds.


2020 ◽  
Author(s):  
Shinji Iizuka ◽  
Ronald P. Leon ◽  
Kyle P. Gribbin ◽  
Ying Zhang ◽  
Jose Navarro ◽  
...  

ABSTRACTThe scaffold protein Tks5α is required for invadopodia-mediated cancer invasion both in vitro and in vivo. We have previously also revealed a role for Tks5 in tumor cell growth using three-dimensional (3D) culture model systems and mouse transplantation experiments. Here we use both 3D and high-density fibrillar collagen (HDFC) culture to demonstrate that native type I collagen, but not a form lacking the telopeptides, stimulated Tks5-dependent growth, which was dependent on the DDR collagen receptors. We used microenvironmental microarray (MEMA) technology to determine that laminin, collagen I, fibronectin and tropoelastin also stimulated invadopodia formation. A Tks5α-specific monoclonal antibody revealed its expression both on microtubules and at invadopodia. High- and super-resolution microscopy of cells in and on collagen was then used to place Tks5α at the base of invadopodia, separated from much of the actin and cortactin, but coincident with both matrix metalloprotease and cathepsin proteolytic activity. Inhibition of the Src family kinases, cathepsins or metalloproteases all reduced invadopodia length but each had distinct effects on Tks5α localization. These studies highlight the crosstalk between invadopodia and extracellular matrix components, and reveal the invadopodium to be a spatially complex structure.


Materials ◽  
2021 ◽  
Vol 14 (23) ◽  
pp. 7255
Author(s):  
Shiva Naseri ◽  
Megan E. Cooke ◽  
Derek H. Rosenzweig ◽  
Maryam Tabrizian

Tooth sensitivity is a painful and very common problem. Often stimulated by consuming hot, cold, sweet, or acidic foods, it is associated with exposed dentin microtubules that are open to dental pulp. One common treatment for tooth hypersensitivity is the application of occlusive particles to block dentin microtubules. The primary methodology currently used to test the penetration and occlusion of particles into dentin pores relies upon dentin discs cut from extracted bovine/human teeth. However, this method is limited due to low accessibility to the raw material. Thus, there is a need for an in vitro dentin model to characterize the effectiveness of occlusive agents. Three-dimensional printing technologies have emerged that make the printing of dentin-like structures possible. This study sought to develop and print a biomaterial ink that mimicked the natural composition and structure of dentin tubules. A formulation of type I collagen (Col), nanocrystalline hydroxyapatite (HAp), and alginate (Alg) was found to be suitable for the 3D printing of scaffolds. The performance of the 3D printed dentin model was compared to the natural dentin disk by image analysis via scanning electron microscopy (SEM), both pre- and post-treatment with occlusive microparticles, to evaluate the degree of dentinal tubule occlusion. The cytocompatibility of printed scaffolds was also confirmed in vitro. This is a promising biomaterial system for the 3D printing of dentin mimics.


Sign in / Sign up

Export Citation Format

Share Document