scholarly journals The Reliability of Using a Laser Device to Assess Deceleration Ability

Sports ◽  
2019 ◽  
Vol 7 (8) ◽  
pp. 191
Author(s):  
Jonty Ashton ◽  
Paul A. Jones

An important component of change of direction speed is the ability to decelerate. Objective methods to examine this quality have been rarely reported in the literature. The aim of this study was to investigate the within- and between-session reliability (intraclass correlation coefficients (ICC), coefficient of variation (CV), standard error of measurement (SEM) and smallest detectable difference (SDD)) of using a laser Doppler device (LAVEG—LAser VElocity Guard) to quantify deceleration ability in 20 amateur rugby union players. Each player performed one familiarisation and two experimental sessions (seven days apart) consisting of three maximal 15 m sprints from a standing start, with an immediate deceleration to a complete stop upon hearing an audible cue at the 15 m mark. Deceleration was evaluated by determining the distance required to decelerate to 75%, 50%, 25% and 0% (‘stopping distance’) of the velocity achieved at 15 m of the maximal sprint. Within-session relative reliability was moderate to good (ICC = 0.64–0.83) with borderline acceptable variation (CVs = 10.51%–16.71%) across all variables. Between-session reliability reported good to excellent relative reliability (ICC = 0.79–0.93) with acceptable absolute reliability, particularly for stopping distance (SEM: 6.54%; SDD: 9.11%). The assessment shows promise as a method to quantify deceleration ability in athletes.

PeerJ ◽  
2020 ◽  
Vol 8 ◽  
pp. e9951
Author(s):  
Dario Martinez-Garcia ◽  
Angela Rodriguez-Perea ◽  
Paola Barboza ◽  
David Ulloa-Díaz ◽  
Daniel Jerez-Mayorga ◽  
...  

Background The evaluation of the force in internal rotation (IR) and external rotation (ER) of the shoulder is commonly used to diagnose possible pathologies or disorders in the glenohumeral joint and to assess patient’s status and progression over time. Currently, there is new technology of multiple joint isokinetic dynamometry that allows to evaluate the strength in the human being. The main purpose of this study was to determine the absolute and relative reliability of concentric and eccentric internal and external shoulder rotators with a functional electromechanical dynamometer (FEMD). Methods Thirty-two male individuals (21.46 ±  2.1 years) were examined of concentric and eccentric strength of shoulder internal and external rotation with a FEMD at velocities of 0.3 m s−1 and 0.6 m s−1. Relative reliability was determined by intraclass correlation coefficients (ICC). Absolute reliability was quantified by standard error of measurement (SEM) and coefficient of variation (CV). Systematic differences across velocities testing circumstances, were analyzed with dependent t tests or repeated-measures analysis of variance in case of 2 or more than 2 conditions, respectively. Results Reliability was high to excellent for IR and ER on concentric and eccentric strength measurements, regardless of velocity used (ICC: 0.81–0.98, CV: 5.12–8.27% SEM: 4.06–15.04N). Concentric outcomes were more reliable than eccentric due to the possible familiarization of the population with the different stimuli. Conclusion All procedures examined showed high to excellent reliability for clinical use. However, a velocity of 0.60 m s−1 should be recommended for asymptomatic male patients because it demands less time for evaluation and patients find it more comfortable.


2011 ◽  
Vol 101 (3) ◽  
pp. 198-207 ◽  
Author(s):  
Sophie De Mits ◽  
Pascal Coorevits ◽  
Dirk De Clercq ◽  
Dirk Elewaut ◽  
James Woodburn ◽  
...  

Background: Abnormal foot posture and deformities are identified as important features in rheumatoid arthritis. There is still no consensus regarding the optimum technique(s) for quantifying these features; hence, a foot digitizer might be used as an objective measurement tool. We sought to assess the validity and reliability of the INFOOT digitizer. Methods: To investigate the validity of the INFOOT digitizer compared with clinical measurements, we calculated Pearson correlation coefficients. To investigate the reliability of the INFOOT digitizer, we calculated intraclass correlation coefficients, SEMs, smallest detectable differences, and smallest detectable difference percentages. Results: Most of the 38 parameters showed good intraclass correlation coefficients, with values greater than 0.9 for 30 parameters and greater than 0.8 for seven parameters. The left heel bone angle expressed a moderate correlation, with a value of 0.609. The SEM values varied between 0.31 and 3.51 mm for the length and width measures, between 0.74 and 5.58 mm for the height data, between 0.75 and 5.9 mm for the circumferences, and between 0.78° and 2.98° for the angles. The smallest detectable difference values ranged from 0.86 to 16.36 mm for length, width, height, and circumference measures and from 2.17° to 8.26° for the angle measures. For the validity of the INFOOT three-dimensional foot digitizer, Pearson correlation coefficients varied between 0.750 and 0.997. Conclusions: In this rheumatoid arthritis population, good validity was demonstrated compared with clinical measurements, and most of the obtained parameters proved to be reliable. (J Am Podiatr Med Assoc 101(3): 198–207, 2011)


Author(s):  
Jakub Gąsior ◽  
Mariusz Pawłowski ◽  
Piotr Jeleń ◽  
Eugene Rameckers ◽  
Craig Williams ◽  
...  

The reliability of handgrip strength (HGS) measurement has been confirmed in adults but has been sparsely addressed in pediatric populations. The aims of this study are twofold: to determine whether sex, age and/or hand-dominance influence the test–retest differences and to establish the reliability level of the HGS measurement in typical developing pediatric participants. A total of 338 participants aged 7–13 years were tested using a digital handgrip strength (HGS) dynamometer (Jamar Plus+ Dynamometer) by the same rater on two testing trials separated by a one-day interval between sessions. The HGS testing was conducted according to the American Society of Hand Therapists recommendations. Relative and absolute reliability statistics were calculated. Age influenced the test–retest difference of the HGS measurement as children compared to preadolescents had lower intraclass correlation coefficients (0.95 vs. 0.98), standard error of measurement (SEM) (0.74 vs. 0.78 kg), smallest detectable difference (SDD) (2.05 vs. 2.16 kg) and higher values of the percentage value of SEM (5.48 vs. 3.44%), normalized SDD (15.52 vs. 9.61%) and a mean difference between the test and retest values (0.50 vs. 0.02 kg) for the dominant hand. The results indicate that the protocol using the Jamar digital handgrip dynamometer is a reliable instrument to measure HGS in participants aged 7–13 years with typical development. Clinicians and researchers therefore can have confidence in determining the minimally clinical effect for HGS.


1991 ◽  
Vol 34 (5) ◽  
pp. 989-999 ◽  
Author(s):  
Stephanie Shaw ◽  
Truman E. Coggins

This study examines whether observers reliably categorize selected speech production behaviors in hearing-impaired children. A group of experienced speech-language pathologists was trained to score the elicited imitations of 5 profoundly and 5 severely hearing-impaired subjects using the Phonetic Level Evaluation (Ling, 1976). Interrater reliability was calculated using intraclass correlation coefficients. Overall, the magnitude of the coefficients was found to be considerably below what would be accepted in published behavioral research. Failure to obtain acceptably high levels of reliability suggests that the Phonetic Level Evaluation may not yet be an accurate and objective speech assessment measure for hearing-impaired children.


Author(s):  
Marcos A Soriano ◽  
G Gregory Haff ◽  
Paul Comfort ◽  
Francisco J Amaro-Gahete ◽  
Antonio Torres-González ◽  
...  

The aims of this study were to (I) determine the differences and relationship between the overhead press and split jerk performance in athletes involved in weightlifting training, and (II) explore the magnitude of these differences in one-repetition maximum (1RM) performances between sexes. Sixty-one men (age: 30.4 ± 6.7 years; height: 1.8 ± 0.5 m; body mass 82.5 ± 8.5 kg; weightlifting training experience: 3.7 ± 3.5 yrs) and 21 women (age: 29.5 ± 5.2 yrs; height: 1.7 ± 0.5 m; body mass: 62.6 ± 5.7 kg; weightlifting training experience: 3.0 ± 1.5 yrs) participated. The 1RM performance of the overhead press and split jerk were assessed for all participants, with the overhead press assessed on two occasions to determine between-session reliability. The intraclass correlation coefficients (ICC) and 95% confidence intervals showed a high reliability for the overhead press ICC = 0.98 (0.97 – 0.99). A very strong correlation and significant differences were found between the overhead press and split jerk 1RM performances for all participants (r = 0.90 [0.93 – 0.85], 60.2 ± 18.3 kg, 95.7 ± 29.3 kg, p ≤ 0.001). Men demonstrated stronger correlations between the overhead press and split jerk 1RM performances (r = 0.83 [0.73-0.90], p ≤ 0.001) compared with women (r = 0.56 [0.17-0.80], p = 0.008). These results provide evidence that 1RM performance of the overhead press and split jerk performance are highly related, highlighting the importance of upper-limb strength in the split jerk maximum performance.


Dysphagia ◽  
2021 ◽  
Author(s):  
Sofie Albinsson ◽  
Lisa Tuomi ◽  
Christine Wennerås ◽  
Helen Larsson

AbstractThe lack of a Swedish patient-reported outcome instrument for eosinophilic esophagitis (EoE) has limited the assessment of the disease. The aims of the study were to translate and validate the Eosinophilic Esophagitis Activity Index (EEsAI) to Swedish and to assess the symptom severity of patients with EoE compared to a nondysphagia control group. The EEsAI was translated and adapted to a Swedish cultural context (S-EEsAI) based on international guidelines. The S-EEsAI was validated using adult Swedish patients with EoE (n = 97) and an age- and sex-matched nondysphagia control group (n = 97). All participants completed the S-EEsAI, the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire-Oesophageal Module 18 (EORTC QLQ-OES18), and supplementary questions regarding feasibility and demographics. Reliability and validity of the S-EEsAI were evaluated by Cronbach’s alpha and Spearman correlation coefficients between the domains of the S-EEsAI and the EORTC QLQ-OES18. A test–retest analysis of 29 patients was evaluated through intraclass correlation coefficients. The S-EEsAI had sufficient reliability with Cronbach’s alpha values of 0.83 and 0.85 for the “visual dysphagia question” and the “avoidance, modification and slow eating score” domains, respectively. The test–retest reliability was sufficient, with good to excellent intraclass correlation coefficients (0.60–0.89). The S-EEsAI domains showed moderate correlation to 6/10 EORTC QLQ-OES18 domains, indicating adequate validity. The patient S-EEsAI results differed significantly from those of the nondysphagia controls (p < 0.001). The S-EEsAI appears to be a valid and reliable instrument for monitoring adult patients with EoE in Sweden.


Author(s):  
Jens Sörensen ◽  
Jonny Nordström ◽  
Tomasz Baron ◽  
Stellan Mörner ◽  
Sven-Olof Granstam ◽  
...  

Abstract Aim To develop a method for diagnosing left ventricular (LV) hypertrophy from cardiac perfusion 15O-water positron emission tomography (PET). Methods We retrospectively pooled data from 139 subjects in four research cohorts. LV remodeling patterns ranged from normal to severe eccentric and concentric hypertrophy. 15O-water PET scans (n = 197) were performed with three different PET devices. A low-end scanner (66 scans) was used for method development, and remaining scans with newer devices for a blinded evaluation. Dynamic data were converted into parametric images of perfusable tissue fraction for semi-automatic delineation of the LV wall and calculation of LV mass (LVM) and septal wall thickness (WT). LVM and WT from PET were compared to cardiac magnetic resonance (CMR, n = 47) and WT to 2D-echocardiography (2DE, n = 36). PET accuracy was tested using linear regression, Bland–Altman plots, and ROC curves. Observer reproducibility were evaluated using intraclass correlation coefficients. Results High correlations were found in the blinded analyses (r ≥ 0.87, P < 0.0001 for all). AUC for detecting increased LVM and WT (> 12 mm and > 15 mm) was ≥ 0.95 (P < 0.0001 for all). Reproducibility was excellent (ICC ≥ 0.93, P < 0.0001). Conclusion 15O-water PET might detect LV hypertrophy with high accuracy and precision.


Author(s):  
Igor Junio de Oliveira Custódio ◽  
Gibson Moreira Praça ◽  
Leandro Vinhas de Paula ◽  
Sarah da Glória Teles Bredt ◽  
Fabio Yuzo Nakamura ◽  
...  

This study aimed to analyze the intersession reliability of global positioning system (GPS-based) distances and accelerometer-based (acceleration) variables in small-sided soccer games (SSG) with and without the offside rule, as well as compare variables between the tasks. Twenty-four high-level U-17 soccer athletes played 3 versus 3 (plus goalkeepers) SSG in two formats (with and without the offside rule). SSG were performed on eight consecutive weeks (4 weeks for each group), twice a week. The physical demands were recorded using a GPS with an embedded triaxial accelerometer. GPS-based variables (total distance, average speed, and distances covered at different speeds) and accelerometer-based variables (Player Load™, root mean square of the acceleration recorded in each movement axis, and the root mean square of resultant acceleration) were calculated. Results showed that the inclusion of the offside rule reduced the total distance covered (large effect) and the distances covered at moderate speed zones (7–12.9 km/h – moderate effect; 13–17.9 km/h – large effect). In both SSG formats, GPS-based variables presented good to excellent reliability (intraclass correlation coefficients – ICC > 0.62) and accelerometer-based variables presented excellent reliability (ICC values > 0.89). Based on the results of this study, the offside rule decreases the physical demand of 3 versus 3 SSG and the physical demands required in these SSG present high intersession reliability.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Minjeong Kim ◽  
Ja Young Oh ◽  
Seon Ha Bae ◽  
Seung Hyeun Lee ◽  
Won Jun Lee ◽  
...  

AbstractWe evaluated the reliability and validity of the 5-scale grading system to interpret the point-of-care immunoassay for tear matrix metalloproteinase (MMP)-9. Six observers graded red bands of photographs of the readout window in MMP-9 immunoassay kit (InflammaDry) two times with 2-week interval based on the 5-scale grading system (i.e. grade 0–4). Interobserver and intraobserver reliability were evaluated using intraclass correlation coefficients. The interobserver agreements were analyzed according to the severity of tear MMP-9 expression. To validate the system, a concentration calibration curve was made using MMP-9 solutions with reference concentrations, then the distribution of MMP-9 concentrations was analyzed according to the 5-scale grading system. Both intraobserver and interobserver reliability was excellent. The readout grades were significantly correlated with the quantified colorimetric densities. The interobserver variance of readout grades had no correlation with the severity of the measured densities. The band density continued to increase up to a maximal concentration (i.e. 5000 ng/mL) according to the calibration curve. The difference of grades reflected the change of MMP-9 concentrations sensitively, especially between grade 2 and 4. Together, our data indicate that the subjective 5-scale grading system in the point-of-care MMP-9 immunoassay is an easy and reliable method with acceptable accuracy.


Sensors ◽  
2021 ◽  
Vol 21 (9) ◽  
pp. 3065
Author(s):  
Ernest Kwesi Ofori ◽  
Shuaijie Wang ◽  
Tanvi Bhatt

Inertial sensors (IS) enable the kinematic analysis of human motion with fewer logistical limitations than the silver standard optoelectronic motion capture (MOCAP) system. However, there are no data on the validity of IS for perturbation training and during the performance of dance. The aim of this present study was to determine the concurrent validity of IS in the analysis of kinematic data during slip and trip-like perturbations and during the performance of dance. Seven IS and the MOCAP system were simultaneously used to capture the reactive response and dance movements of fifteen healthy young participants (Age: 18–35 years). Bland Altman (BA) plots, root mean square errors (RMSE), Pearson’s correlation coefficients (R), and intraclass correlation coefficients (ICC) were used to compare kinematic variables of interest between the two systems for absolute equivalency and accuracy. Limits of agreements (LOA) of the BA plots ranged from −0.23 to 0.56 and −0.21 to 0.43 for slip and trip stability variables, respectively. The RMSE for slip and trip stabilities were from 0.11 to 0.20 and 0.11 to 0.16, respectively. For the joint mobility in dance, LOA varied from −6.98–18.54, while RMSE ranged from 1.90 to 13.06. Comparison of IS and optoelectronic MOCAP system for reactive balance and body segmental kinematics revealed that R varied from 0.59 to 0.81 and from 0.47 to 0.85 while ICC was from 0.50 to 0.72 and 0.45 to 0.84 respectively for slip–trip perturbations and dance. Results of moderate to high concurrent validity of IS and MOCAP systems. These results were consistent with results from similar studies. This suggests that IS are valid tools to quantitatively analyze reactive balance and mobility kinematics during slip–trip perturbation and the performance of dance at any location outside, including the laboratory, clinical and home settings.


Sign in / Sign up

Export Citation Format

Share Document