scholarly journals An Interactive Task Conditioning System Featuring Personal Comfort Models and Non-Intrusive Sensing Techniques: A Field Study in Shanghai

Technologies ◽  
2021 ◽  
Vol 9 (4) ◽  
pp. 90
Author(s):  
Siliang Lu ◽  
Erica Cochran Hameen

Heating, ventilation and air-conditioning (HVAC) systems play a key role in shaping office environments. However, open-plan office buildings nowadays are also faced with problems like unnecessary energy waste and an unsatisfactory shared indoor thermal environment. Therefore, it is significant to develop a new paradigm of an HVAC system framework so that everyone could work under their preferred thermal environment and the system can achieve higher energy efficiency such as task ambient conditioning system (TAC). However, current task conditioning systems are not responsive to personal thermal comfort dynamically. Hence, this research aims to develop a dynamic task conditioning system featuring personal thermal comfort models with machine learning and the wireless non-intrusive sensing system. In order to evaluate the proposed task conditioning system performance, a field study was conducted in a shared office space in Shanghai from July to August. As a result, personal thermal comfort models with indoor air temperature, relative humidity and cheek (side face) skin temperature have better performances than baseline models with indoor air temperature only. Moreover, compared to personal thermal satisfaction predictions, 90% of subjects have better performances in thermal sensation predictions. Therefore, personal thermal comfort models could be further implemented into the task conditioning control of TAC systems.

2013 ◽  
Vol 805-806 ◽  
pp. 1620-1624 ◽  
Author(s):  
Wan Ying Qu

A thermal comfort field study was investigated in residential buildings of cold regions in transition season during which the indoor thermal environment conditions are measured, the thermal sensation value of the occupants is questioned and recorded. A seven-point thermal sensation scale was used to evaluate the thermal sensation. The statistical method was used to analyze the data and the conclusions are as follows in transition season: clothing increase in 0.1clo when the indoor air temperature is lowered by 1°C; and clothing will be a corresponding increase in 0.06clo when the outdoor air temperature is lowered by 1°C; clothing also varies with gender, age, weight and thermal history and other related; the measured thermal neutral temperature is 21.3°C; and the minimum accepted temperature is 11.4 °C in transition season in cold regions. Most people choose to change clothes, switch and other passive measures, and occasionally take active measures of heater, electric fans and others.


2020 ◽  
pp. 014459872096921
Author(s):  
Yanru Li ◽  
Enshen Long ◽  
Lili Zhang ◽  
Xiangyu Dong ◽  
Suo Wang

In the Yangtze River zone of China, the heating operation in buildings is mainly part-time and part-space, which could affect the indoor thermal comfort while making the thermal process of building envelope different. This paper proposed to integrate phase change material (PCM) to building walls to increase the indoor thermal comfort and attenuate the temperature fluctuations during intermittent heating. The aim of this study is to investigate the influence of this kind of composite phase change wall (composite-PCW) on the indoor thermal environment and energy consumption of intermittent heating, and further develop an optimization strategy of intermittent heating operation by using EnergyPlus simulation. Results show that the indoor air temperature of the building with the composite-PCW was 2–3°C higher than the building with the reference wall (normal foamed concrete wall) during the heating-off process. Moreover, the indoor air temperature was higher than 18°C and the mean radiation temperature was above 20°C in the first 1 h after stopping heating. Under the optimized operation condition of turning off the heating device 1 h in advance, the heat release process of the composite-PCW to the indoor environment could maintain the indoor thermal environment within the comfortable range effectively. The composite-PCW could decrease 4.74% of the yearly heating energy consumption compared with the reference wall. The optimization described can provide useful information and guidance for the energy saving of intermittently heated buildings.


1987 ◽  
Vol 1 (2) ◽  
pp. 74-77 ◽  
Author(s):  
S C Foo ◽  
WO Phoon

Two hundred and eighty-five Office workers were surveyed and the micro-climatic conditions in which they worked were measured to evaluate their preferred temperature. About 78% of workers considered the natural tropical climate uncomfortable. However, 76% to 87% of workers in airconditioned Offices approved of their thermal environment if its temperature ranged from 21°C to 27°C. Many workers who felt that the temperature produced a neutral thermal sensation in the body as a whole, tended to complain that their heads were too warm and at the same time their limbs too cool. About 60% of workers in airconditioned Offices were exposed to an air temperature of less than 24°C. Present data suggest that an air temperature of 27°C would be comfortable for more than 80% of workers.


2016 ◽  
Vol 34 (4/5) ◽  
pp. 427-445 ◽  
Author(s):  
Baharuddin Hamzah ◽  
Muhammad Taufik Ishak ◽  
Syarif Beddu ◽  
Mohammad Yoenus Osman

Purpose The purpose of this paper is to analyse thermal comfort and the thermal environment in naturally ventilated classrooms. Specifically, the aims of the study were to identify the thermal environment and thermal comfort of respondents in naturally ventilated university classrooms and compare them with the ASHRAE and Indonesian National Standard (SNI); to check on whether the predicted mean vote (PMV) model is applicable or not for predicting the thermal comfort of occupants in naturally ventilated university classrooms; and to analyse the neutral temperature of occupants in the naturally ventilated university classrooms. Design/methodology/approach The study was carried out at the new campus of Faculty of Engineering, Hasanuddin University, Gowa campus. A number of field surveys, which measured thermal environments, namely, air temperature, mean radiant temperature (MRT), relative humidity, and air velocity, were carried out. The personal activity and clothing properties were also recorded. At the same time, respondents were asked to fill a questionnaire to obtain their thermal sensation votes (TSV) and thermal comfort votes (TCV), thermal preference, and thermal acceptance. A total of 118 respondents participated in the study. Before the survey was conducted, a brief explanation was provided to the participants to ensure that they understood the study objectives and also how to fill in the questionnaires. Findings The results indicated that the surveyed classrooms had higher thermal environments than those specified in the well-known ASHRAE standard and Indonesian National Standard (SNI). However, this condition did not make respondents feel uncomfortable because a large proportion of respondents voted within the comfort zone (+1, 0, and −1). The predictive mean vote using the PMV model was higher than the respondents’ votes either by TSV or by TCV. There was a huge difference between neutral temperature using operative temperature (To) and air temperature (Ta). This difference may have been because of the small value of MRT recorded in the measured classrooms. Originality/value The research shows that the use of the PMV model in predicting thermal comfort in the tropic region might be misleading. This is because PMV mostly overestimates the TSV and TCV of the respondents. People in the tropic region are more tolerant to a higher temperature. On the basis of this finding, there is a need to develop a new thermal comfort model for university classrooms that is particularly optimal for this tropical area.


2020 ◽  
Vol 194 ◽  
pp. 05013
Author(s):  
Xiaowei Hong ◽  
Guangjin Zhang ◽  
Yufeng Zhang

Indoor thermal environment of Hui style traditional houses is depended on surrounding environments, building layouts and envelope. Quantitative analysis of the effects of building layouts and envelope on indoor thermal environment is of great significance for preventions of traditional houses and design of new archaized houses. A field investigation was conducted on thirty-six traditional houses from nine villages in Wuyuan, and the typical buildings’ layout and envelope were determined. Four traditional buildings in different location in Wuyuan were selected for continual recording. The four buildings with four types of building layouts and envelope were analyzed by using local adaptive thermal comfort model, and the effects of building layouts and envelope of traditional buildings were clearly revealed. The most crucial way to improve indoor thermal environment in Hui style traditional buildings was raising the indoor air temperature.


Buildings ◽  
2018 ◽  
Vol 9 (1) ◽  
pp. 4 ◽  
Author(s):  
Rajan KC ◽  
Hom Rijal ◽  
Masanori Shukuya ◽  
Kazui Yoshida

A home energy management system (HEMS) shows the energy used indoors so that the energy waste can be easily identified and reduced. Thermal comfort is related to the trend of energy use in buildings. We conducted a survey in a condominium equipped with a HEMS to determine the indoor thermal environment and various behaviors of the occupants taken for thermal comfort adjustment. The results showed that there is a large variation of indoor air temperatures according to season, floor and flat. We categorized families into two groups, one with higher and the other with lower average indoor temperatures. The indoor air temperature of the higher temperature group in summer was found to be higher than the recommended indoor temperature during the summer season in Japan. The higher temperature group tended to adopt behaviors, such as window opening and using a fan more often, than the lower temperature group. Due to the moderately high insulating levels in the building surveyed, the indoor air temperature of both groups was not low in winter. Heating was used less and irregular. The overall results indicate that the groups of families behaved differently to adjust the indoor thermal environment even though they were equipped with the same HEMS system.


2021 ◽  
pp. 277-277
Author(s):  
Xiaozhou Wu ◽  
Genglin Liu ◽  
Jie Gao ◽  
Shuang Wu

A ceiling cooling (CC) system integrated with a mechanical ventilation system is an advanced HVAC system for the modern office building with glass curtain wall. In this paper, considering the influence of heat transfer of external envelope, the indoor thermal environment and human thermal comfort were objectively measured and subjectively evaluated in a ceiling cooling room with mixing ventilation (MV) or underfloor air distribution (UFAD). Indoor physical parameters and human skin temperatures were measured as the chilled ceiling surface temperature and supply air temperature were 17.1?C-17.6?C and 22.2?C - 22.6?C. Simultaneously, 16 subjects (8 males and 8 females) were selected to subjectively evaluate the thermal environment. The results showed that the difference between mean radiant temperature and air temperature in the occupied zone was 0.8?C with CC+MV and 1.2?C with CC+UFAD, and the indoor air velocity was 0.17m/s with CC+MV and 0.13m/s with CC+UFAD. In addition, the calculated and measured thermal sensation votes with CC+MV were all slightly less than those with CC+UFAD. Therefore, ventilation system type had a slight impact on the indoor thermal environment and human thermal comfort in the ceiling cooling room.


2021 ◽  
Vol 2 (1) ◽  
pp. 20-27
Author(s):  
Azka Millatina ◽  
Nedyomukti Imam Syafii

Thermal comfort is a basic human demand in interacting with space/architectural design. Determination of thermal comfort criteria can help the designer/architect in improving quality, function, and user thermal experience in an artificial environment. ISO 7730: 1994 standard states that the thermal sensation experienced by humans is the result of climate parameters (such as air temperature, radiation temperature, humidity, and wind speed) and human parameters (such as activity and clothing). These parameters were the focus of this study. The work program of this research collaboration was basically divided into 2 phases of activity, namely measuring and monitoring the conditions of thermal comfort in the Gallery 1 environment, Affandi Museum and providing recommendations for improvement of Gallery 1 thermal environment conditions. Primary data was taken from the indoor and outdoor measurement of air temperature, relative humidity and air velocity for 6 months. Physical architectural measurement of this study building and questionnaire methods followed the ASHRAE scale which was simplified to determine the level of thermal comfort, the scale of which was 2 (hot) to -2 (cold). The result of the measurement and analysis using a calculator based upon the ASHARE standard indicated that Gallery 1 of the Affandi Museum was in uncomfortable conditions. While the results of the questionnaire of 20 analyzes showed that at least 87,5% of respondents felt discomfort in Gallery 1, however, 60% of the respondent were still able to enjoy the collection and the atmosphere in gallery 1. The effective temperature index which provide 27,5-27,6 C and 66,7% RH as acceptable indoor environment in warm humid climate at Affandi museum case.


2021 ◽  
Vol 39 (1) ◽  
pp. 275-291
Author(s):  
Md Sarfaraz Alam ◽  
Urmi Ravindra Salve

There are ample literature studies available, focusing on hot-humid built environment, which have achieved an increase in thermal comfort conditions by proper installation of ventilation-systems. The present thermal comfort study has been carried out in the kitchen environment of a non-air-conditioned railway pantry car in Indian Railways. The purpose is to enhance thermal comfort level under the currently applied ventilation system inside the kitchen of pantry car by determining the standard effective temperature (SET) index. During the summer and winter seasons, a field study was carried out to obtain the value of air temperature, globe temperature, relative humidity, and air velocity inside the pantry car for estimation of the SET index. A computational fluid dynamics (CFD) analysis was used to obtain a better-modified case model of the pantry car kitchen for the improvement of thermal comfort. The design interventions for the pantry car kitchen were created, with emphasis on increasing energy efficiency based on low-power consumption air ventilation system. The study results indicated that, modified case-I model has a better ventilation design concept as compare to the existing and other models, which increased the air velocity and significantly decreased the air temperature inside the kitchen of pantry car at all cooking periods. A value of SET (28.6–30℃) was found with a comfortable thermal sensation within all cooking periods, which is better for the pantry car workers. This finding suggests a sustainable improvement in the thermal environment of the "non-air-conditioned" pantry car kitchen in the Indian Railways, which can be applied immediately.