scholarly journals Pressurized Solvent Extraction with Ethyl Acetate and Liquid Chromatography—Tandem Mass Spectrometry for the Analysis of Selected Conazole Fungicides in Matcha

Toxics ◽  
2018 ◽  
Vol 6 (4) ◽  
pp. 64 ◽  
Author(s):  
Renata Raina-Fulton ◽  
Aisha Mohamad

The extraction of powdered nutraceuticals is challenging due to the low water content and high concentration of matrix components that can lead to significant matrix effects in liquid chromatography-positive ion electrospray ionization-tandem mass spectrometry (LC-ESI+-MS/MS). In this study we assess the feasibility of using pressurized solvent extraction with ethyl acetate to reduce the co-extraction of polar matrix components. Pigment attributed to chlorophyll was removed with in-cell clean-up utilizing Anasorb 747, Florisil®, and C18. Visible inspection of the extracts showed that pigment was removed from matcha, a powdered green tea sample. Pressurized solvent extraction with in-cell clean-up can be utilized to remove pigments from powdered samples such as nutraceuticals. Average matrix effect of the 32 target analytes that observed mass spectrometric signal suppression or soft MS signal enhancement was −41 ± 19% with the majority of analytes having a protonated molecular ion with m/z of 250 to 412. As generally moderate signal suppression was observed for conazole fungicides and structurally related compounds analyzed by LC-ESI+-MS/MS, it is recommended that matrix matched or standard addition calibration is used for quantitation. Catachins, other polyphenols, and caffeine are expected to contribute to the matrix effects observed in LC-ESI+-MS/MS. Diniconazole, fenbuconazole, and tebufenozide were the only target analytes with severe MS signal enhancement. Low levels (0.002–0.004 mg/kg) of prothioconazole-desthio and flusilazole were detected, along with trace levels of tebuthiuron in matcha.

2010 ◽  
Vol 56 (8) ◽  
pp. 1234-1244 ◽  
Author(s):  
Michael Vogeser ◽  
Christoph Seger

BACKGROUND Novel mass spectrometric techniques such as atmospheric pressure ionization and tandem mass spectrometry have substantially extended the spectrum of clinical chemistry methods during the past decade. In particular, liquid chromatography tandem–mass spectrometry (LC-MS/MS) has become a standard tool in research laboratories as well as in many clinical laboratories. Although LC-MS/MS has features that suggest it has a very high analytical accuracy, potential sources of inaccuracy have recently been identified. CONTENT The sources of inaccuracy in LC-MS/MS methods used in the routine quantification of small molecules are described and discussed. Inaccuracy of LC-MS/MS methods can be related to the process of ionization through the insource transformation of conjugate metabolites or target analytes and may also be attributable to ionization matrix effects that have a differential impact on target analytes and internal-standard compounds. Inaccuracy can also be associated with the process of ion selection, which mainly occurs when compounds from the sample matrix share mass transitions with a target analyte. In individual assays, most potential sources of inaccuracy can be controlled by sufficient LC separation–based sample workup before MS analysis. SUMMARY LC-MS/MS methods should undergo rigorous and systematic validation before introduction into patient care.


Sign in / Sign up

Export Citation Format

Share Document