Experimental Study on Sand and Cement Replacement by Termite Mound Soil

Author(s):  
Harish R ◽  
Ramesh S ◽  
Tharani A ◽  
Mageshkumar P

This paper presents the results of an experimental investigation of the compressive strength of concrete cubes containing termite mound soil. The specimens were cast using M20 grade of concrete. Two mix ratios for replacement of sand and cement are of 1:1.7:2.7 and 1:1.5:2.5 (cement: sand: aggregate) with water- cement ratio of 0.45 and varying combination of termite mound soil in equal amount ranging from 30% and 40% replacing fine aggregate (sand) and cement from 10%,15%,20% were used. A total of 27 cubes, 18 cylinders and 6 beams were cast by replacing fine aggregate, specimens were cured in water for 7,14 and 28 days. The test results showed that the compressive strength of the concrete cubes increases with age and decreases with increasing percentage replacement of cement and increases with increasing the replacement of sand with termite mound soil cured in water. The study concluded that termite mound cement concrete is adequate to use for construction purposes in natural environment.

Jurnal CIVILA ◽  
2021 ◽  
Vol 6 (2) ◽  
pp. 213
Author(s):  
Asrul Majid ◽  
Hammam Rofiqi Agustapraja

Infrastructure development is one of the important aspects of the progress of a country where most of the constituents of infrastructure are concrete. The most important constituent of concrete is cement because its function is to bind other concrete materials so that it can form a hard mass. The large number of developments using cement as a building material will leave quite a lot of cement bags.In this study, the authors conducted research on the effect of adding cement waste to the compressive strength of concrete. This study used an experimental method with a total of 24 test objects. The test object is in the form of a concrete cylinder with a diameter of 15 cm and a height of 30 cm and uses variations in the composition of the addition of cement waste cement as a substitute for fine aggregate, namely 0%, 2%, 4% and 6%. K200). The compressive strength test was carried out at the age of 7 days and 28 days.The test results show that the use of waste as a partial substitute for fine aggregate results in a decrease in the compressive strength of each mixture. at the age of 7 days the variation of 2% is 16.84 MPa, 4% is 11.32 MPa and for a mixture of 6% is 6.68 MPa. Meanwhile, the compressive strength test value of 28 days old concrete in each mixture decreased by ± 6 MPa. So the conclusion is cement cement waste cannot be used as a substitute for fine aggregate in fc 16.6 (K200) quality concrete because the value is lower than the specified minimum of 16.6 MPa.


2019 ◽  
Vol 18 (1) ◽  
Author(s):  
Djedjen Achmad ◽  
Desi Supriyan

ABSTRACTHas been researched the impact of mud in aggregate on geopolymer concrete with studies using the cement concrete as a reference. In this study both of concrete are mixed with a variation of mud of 0%, 0.75%, 3% and 5.75% of the combined aggregate weight. Compressive strength of cement concrete is designed with a target of 300 kg / cm2 and geopolymer concrete is made with water binder ratio (w/b) 0.25, Molarity 12 M, the ratio of sodium silicate and sodium hydroxide 1.5. At the age of 3, 7, 14 and 28 day tested of compressive strength, while the spliting test, flexural tensile strength, and modulus of elasticity are tested at 28 days. From the test results, the higher mud content in aggregate , the mechanical properties of the concrete are decreased. Based on testing of compressive strength in cement concrete at 28 days, with a 3% mud content (the content of the reference mud) turns of compressive strength decreased by 77.356%. Of the percentage reduction on the compressive strength of the cement concrete, can be compared to the mud content in geopolymer concrete at 2.04%. Thus the maximum mud on geopolymer concrete aggregate is, for coarse aggregate of 0.68% and a maximum mud content for fine aggregate was 3.4%.Key words : Mud, aggregate, concrete, cement, geopolimer, strengthABSTRAKTelah diteliti dampak kadar lumpur pada agregat untuk beton geopolimer dengan penelitian menggunakan benda uji beton semen sebagai acuan dan beton geopolimer. Dalam penelitian ini ke dua beton tersebut dicampur dengan lumpur gabungan agregat kasar dan agregat halus dengan variasi 0 %, 0.75 %, 3 % dan 5,75 % dari berat agregat gabungan. Beton semen dirancang dengan target kuat tekan 300 kg/cm2 dan beton geopolimer dibuat dengan campuran water binder ratio (w/b) 0.25, Molaritas 12 M, perbandingan sodium silikat dan sodium hidroksida 1.5. Pada umur 3, 7, 14 dan 28 hari dilakukan uji kuat tekan, sedangkan uji kuat tarik belah, uji kuat tarik lentur, dan modulus elastisitas dilakukan pada umur 28 hari. Dari hasil uji terlihat bahwa semakin tinggi kadar lumpur pada agregat, karakteristik mekanis kedua beton tersebut mengalami penurunan. Berdasarkan pengujian kuat tekan pada beton semen umur 28 hari, dengan kadar lumpur 3 % (kadar lumpur referensi) ternyata beton semen mengalami penurunan kuat tekan sebesar 77.356 %. Dari persentase penurunan kuat tekan beton semen tersebut, diplot pada grafik kuat tekan beton geopolimer maka persentase kadar lumpur gabungan yang mengalami penurunan 77.356 % adalah 2.04 %. Dengan demikian kadar lumpur maksimum pada agregat beton geopolimer adalah, untuk agregat kasar sebesar 0.68 % dan kadar lumpur maksimum untuk agregat halus adalah 3.4 %.Kata kunci : Lumpur, agregat, beton, semen, geopolimer, kekuatan


2012 ◽  
Vol 575 ◽  
pp. 100-103 ◽  
Author(s):  
Dong Sheng Shi ◽  
Ping Han ◽  
Zheng Ma ◽  
Jing Bo Wang

In this paper, the experiment about compressive strength of concrete using granulated blast furnace slag as fine aggregate was introduced. In this experiment, granulated blast furnace slag fine aggregates that were produced by two different steel factory and natural river sands that came from two different producing area were been used, and compressive strength of concrete for testing were four levels from ordinary strength level to high strength level. As results, the compressive strength of concrete that used granulated blast furnace slag as fine aggregate increase with increasing of concrete age as good as the concrete used nature river sand. At the early age of 3 days and 7days, whether water-cement ratio, the compressive strength of concrete using slag fine aggregate is always lower than concrete using river sand. At the long age of 91 days, the compressive strength of concrete using slag fine aggregate exceed the concrete using river sand when water-cement ratio was greater than 30%. The compressive strength of concrete using granulated blast furnace slag as fine aggregate can exceed 80N/mm2, the granulated blast furnace slag can be used in high-strength concrete.


2013 ◽  
Vol 795 ◽  
pp. 356-359 ◽  
Author(s):  
Mohd Irwan Juki ◽  
Mazni Awang ◽  
Mahamad Mohd Khairil Annas ◽  
Koh Heng Boon ◽  
Norzila Othman ◽  
...  

This paper describes the experimental investigation of relationship between splitting tensile strength and flexural strength with the compressive strength of concrete containing waste PET as fine aggregates replacement. Waste PET was reprocesses and used as the artificial fine aggregate at the replacement volume of 25%, 50% and 75%, Cylindrical and prism specimens were tested to obtain the compressive, splitting tensile and flexural strength at the age of 28 days. Based on the investigation, a relationship for the prediction of splitting tensile and flexural strength was derived from the compressive strength of concrete containing waste PET as fine agglegate replacement.


2018 ◽  
Vol 4 (4) ◽  
pp. 724 ◽  
Author(s):  
Aneel Manan ◽  
Mushtaq Ahmad ◽  
Fawad Ahmad ◽  
Abdul Basit ◽  
Muhammad Nasir Ayaz Khan

The aim of the study is to investigate compressive strength of pervious concrete by reduction of fine aggregate from zero to 100%, additionally investigate infiltration rate of pervious concrete. Experimental study has conducted at Cecos Engineering University Peshawar. The pervious concrete samples were produced for 7 and 28 days. Compressive strength of pervious concrete indicated higher reduction of the sand reduces compressive strength and almost 50% compressive strength decreased by reduction of 100% sand from the design mix. On the other side, infiltration rate for 28 days shows direct relation above 40% reduction of sand and highest 273% of infiltration rate by reducing 100% sand from the design mix. The 90% reduction of sand from concrete give considerable compressive strength of 2150 psi and infiltration rate of 165.79 inch/hour, which can be recommended for pavements of parking and walking area.


2019 ◽  
Vol 2 (1) ◽  
pp. 61-66
Author(s):  
Abdul Gaus ◽  
Imran Imran ◽  
Chairul Anwar ◽  
Liska Novianti

The Pumice sand is a bright colored butian type, containing foam made from glass-walled bubbles and usually referred to as silicate volcanic glass granules. This pumice sand can be used as a substitute for normal sand as fine aggregate in a mixture of concrete mix. Based on the characteristic test examination, it can be seen that in testing the characteristics of pumice sand to the specifications of normal sand in specific gravity testing and weight testing of quicksand obtained results that are smaller than the specifications of normal sand and absorption tests obtained results greater than specifications on normal sand. The results of the normal sand compressive strength at BN is 250.95 kg /cm2 while the results of the floating sand concrete compressive strength on BPA is 224, 965 kg /cm2. Based on the research it can be concluded that with the same quality of concrete, the quality of K-250 is different in comparison to the compressive strength of concrete in normal sand and pumice sand concrete shows almost the same results. Therefore, more in-depth research is needed regarding the use of pumice sand instead of normal sand in a mixture of concrete mix


2020 ◽  
Vol 39 (3) ◽  
Author(s):  
O.O. Aderinola ◽  
Y. Yusuf ◽  
O.O. Omotayo

This study assessed the effect of partial replacement of cement with plantain peel ash (PPA) and Polystrene (POL) on the compressive strength of concrete as a means of managing waste. Concrete specimens were prepared with a mix ratio of 1:2:4 (cement: sand: granite) water/cement ratio of 0.6, thereafter cement was partially replaced with PPA, POL and PPA/POL in increasing percentages of 5, 10, 15 and 20% by weight. Physical, chemical and microstructural analyses were also conducted on the aggregates and materials used. Workability of the concrete specimens was observed to improve upon addition of PPA and POL separately but not with blended PPA/POL while compressive strength decreased with addition of the three compounds. The observed results can be attributed to the lack of sufficient cementitious properties in the materials, and hence, the study discourages the use of these materials as they do not significantly improve concrete strength. Keywords: Plantain Peel Ash (PPA), Polystyrene (POL), Compressive Strength, Sustainable Waste Management


The presented research focuses on the experimental investigation to calculate the suitability of using recycled brick ballast obtained as demolition debris to serve as partial substitute to coarse aggregates for concrete of different grades like M10, M15, M20, M25 and by varying the product mix in different replacement proportions as 0%, 25%, 50%, 75% and 100% by weight. The proposed methodology is based on a series of tests carried out, focusing mainly on the workability and characteristic strength analysis of concrete with graded brick ballast and comparing them with the conventional cement concrete. The experimental work included several types of concrete made keeping the water-cement ratio as 0.45 and with target slump value 70-100 mm. The influence of replacing different percentages of coarse aggregates to produce different concrete grades was closely observed. The conclusion drawn from the test results conforms, the possibility to use brick ballast in concrete for M25 grade with 25% by weight of the coarse aggregate as optimum value.