Determination of distortions of the driven links of multilink mechanisms of technological machines

2020 ◽  
pp. 22-25
Author(s):  
V.A. Grigorev ◽  
V.I. Terentev

A method is proposed for determining the distortions of the driven links of technological machines as applied to the heald movement mechanisms (HMM) of the weaving machines during yaw formation. The method is based on calculating the reduced total gaps to the left and right ends of the heald as functions of the position of the leading link of the HMM and on statistical analysis. Keywords heald movement mechanism, transfer function, kinematic pair, gap. [email protected]

2018 ◽  
Vol 3 (2) ◽  
pp. 52-61
Author(s):  
Dzikra Arwie ◽  
Islawati

Leukocytes or white blood cells have a characteristic characteristic of different cells. Determination of the impression of the number of leukocytes is determined in the number of cells in the field of view. While the number of viewable field cells expressed is still quite varied. The purpose of this study was to determine the number of leukocytes in the field of view and expressed the impression of a sufficient amount. This research was conducted at the Laboratory of Health Analyst Department Panrita Husada Bulukumba on 9 April 2017 to 14 July 2017. This type of research is a laboratory observation that aims to determine the criteria for assessing the impression of the number of leukocytes on a peripheral blood smear. Data analysis using statistical analysis is the average and standard deviations to determine the impression of the number of leukocytes and use 3 inspection zones. The results of this study obtained results in zone IV the number of leukocyte impressions said to be sufficient was 7-10, in zone V the number of leukocyte impressions said to be sufficient was 4-9, and in zone VI the number of leukocyte impressions said to be sufficient was 3-8.  


1977 ◽  
Vol 12 (1) ◽  
pp. 27-50 ◽  
Author(s):  
L.A. Behie ◽  
J.E. Zajic ◽  
D. Berk ◽  
R.J.P. Brouzes ◽  
V.A. Naish

Abstract Although Daphnia magna have been widely used in the determination of the toxicity of various substances, there are no reports in the literature that describe a rigorous bioassay method using this organism as a test species. The test described herein involves the standariza-tion of various important aspects of the method such as the age of the test organisms, and the dilution water used for the preparation of the various toxicant concentrations. Also described is a simple method for the statistical analysis of the results. The sensitivity of the proposed bioassay is demonstrated by determining the toxicity of various pulp and paper effluents. Finally, extensive bioassays were carried out simultaneously with rainbow trout and Daphnia magna indicating that Daphnia are as good a biological indicator of acute toxicity as fish.


2012 ◽  
Vol 22 (4) ◽  
pp. 451-465 ◽  
Author(s):  
Tadeusz Kaczorek

A new modified state variable diagram method is proposed for determination of positive realizations with reduced numbers of delays and without delays of linear discrete-time systems for a given transfer function. Sufficient conditions for the existence of the positive realizations of given proper transfer function are established. It is shown that there exists a positive realization with reduced numbers of delays if there exists a positive realization without delays but with greater dimension. The proposed methods are demonstrated on a numerical example.


2021 ◽  
pp. 107754632110337
Author(s):  
Arup Maji ◽  
Fernando Moreu ◽  
James Woodall ◽  
Maimuna Hossain

Multi-Input-Multi-Output vibration testing typically requires the determination of inputs to achieve desired response at multiple locations. First, the responses due to each input are quantified in terms of complex transfer functions in the frequency domain. In this study, two Inputs and five Responses were used leading to a 5 × 2 transfer function matrix. Inputs corresponding to the desired Responses are then computed by inversion of the rectangular matrix using Pseudo-Inverse techniques that involve least-squared solutions. It is important to understand and quantify the various sources of errors in this process toward improved implementation of Multi-Input-Multi-Output testing. In this article, tests on a cantilever beam with two actuators (input controlled smart shakers) were used as Inputs while acceleration Responses were measured at five locations including the two input locations. Variation among tests was quantified including its impact on transfer functions across the relevant frequency domain. Accuracy of linear superposition of the influence of two actuators was quantified to investigate the influence of relative phase information. Finally, the accuracy of the Multi-Input-Multi-Output inversion process was investigated while varying the number of Responses from 2 (square transfer function matrix) to 5 (full-rectangular transfer function matrix). Results were examined in the context of the resonances and anti-resonances of the system as well as the ability of the actuators to provide actuation energy across the domain. Improved understanding of the sources of uncertainty from this study can be used for more complex Multi-Input-Multi-Output experiments.


Healthcare ◽  
2021 ◽  
Vol 9 (8) ◽  
pp. 936
Author(s):  
Milan Kojić ◽  
Branka Protić Gava ◽  
Milan Bajin ◽  
Marko Vasiljević ◽  
Jasmina Bašić ◽  
...  

Background: The research objective of the study is to determine the differences in the manifestation of the motor status of normally fed preschool test subjects, classified into groups according to foot status. Methods: This is a simple, comparative observational study. Preschool children included in this study have been subjected to anthropometric measurements in order to determine BMI, tests for motor skills assessment (running at 20 m from a high start, standing broad jump, backwards polygon, rectangular seated forward bend, plate tapping, sit-ups for 60 s, and bent arm hang), and a determination of foot status. The total sample was comprised of 202 test subjects who attended a regular sports program, aged 3.9 to 6.5 years of decimal age (M = 141; Age = 5.3 ± 0.74; Height = 117.3 ± 7.1; Weight = 22 ± 3.7; F = 61; Age = 5.1 ± 0.73; Height = 114.9 ± 7.4; Weight = 21.2 ± 3.8), of which 153 (75.7%) were normally fed, 6 (3%) were undernourished, 30 were overweight (14.9%), and 13 were obese (6.4%). Results: In the total sample, 30 (14.9%) subjects had normal arch feet, 90 (44.6%) high arched feet, and 41 (20.3%) flat feet. We found 41 (20.3%) subjects who had different left and right foot statuses within this sample. The data were processed by means of nonparametric tests (the Kruskal–Wallis and Mann–Whitney U tests) at a significance level p ≤ 0.05. Conclusion: The results show that there is a statistically significant difference between groups of subjects with different foot statuses in the manifestation of motor status in most tests, with a significance level of p ≤ 0.01, and in tests of sit-ups for 60 s and the bent arm hang, there is a statistically significant difference, the level of which is p ≤ 0.05. It is only in the inclination test of rectangular seated forward bend that no statistically significant difference was displayed.


1966 ◽  
Vol 49 (3) ◽  
pp. 511-515 ◽  
Author(s):  
R W Henningson

Abstract Bath level, sample temperature, rate of stirring, degree of supercooling, sample size, sample isolation, and refreezing of the sample were the variables in the thermistor cryoscopic method for the determination of the freezing point value of milk chosen for study. Freezing point values were determined for two samples of milk and two secondary salt standards utilizing eight combinations of the seven variables in two test patterns. The freezing point value of the salt standards ranged from –0.413 to –0.433°C and from –0.431 to –0.642°C. The freezing point values of the milk samples ranged from –0.502 to –0.544°C and from –0.518 to –0.550°C. Statistical analysis of the data showed that sample isolation was a poor procedure and that other variables produced changes in the freezing point value ranging from 0.001 to 0.011°C. It is recommended that specific directions be instituted for the thermistor cryoscopic method, 15.040–15.041, and that the method be subjected to a collaborative study.


Author(s):  
Lorenzo Ferrari ◽  
Guido Soldi ◽  
Alessandro Bianchini ◽  
Enzo Dalpane

A good prediction of the failure ratio of wind turbine (WT) components is pivotal to define a correct maintenance program and reduce the downtime periods. Even a small failure can lead to long downtime periods and high repairing costs. The installation sites, which generally have limited accessibility, and the necessity of special facilities to reach the components inside the nacelle, also play a key role in the correct management of WTs. In this study, a detailed survey on the failures occurred to the WTs managed by the Italian operator “e2i energie speciali” (more than 550 machines) over 16 years was performed and the results were analyzed in detail. Each failure was classified by considering the damaged component and the related downtime period. The analysis allowed the determination of several useful results such as the trend of failure occurrence with machine age and the identification of components and macrocomponents which are more critical in terms of both number of occurrences and downtime periods. The combination of component failure occurrences and related downtime periods was also computed to estimate which component is most critical for WT operation.


2012 ◽  
Vol 60 (3) ◽  
pp. 605-616
Author(s):  
T. Kaczorek

Abstract The problem of existence and determination of the set of positive asymptotically stable realizations of a proper transfer function of linear discrete-time systems is formulated and solved. Necessary and sufficient conditions for existence of the set of the realizations are established. A procedure for computation of the set of realizations are proposed and illustrated by numerical examples.


Sign in / Sign up