scholarly journals Silica nanoparticles are less toxic to human lung cells when deposited at the air–liquid interface compared to conventional submerged exposure

2014 ◽  
Vol 5 ◽  
pp. 1590-1602 ◽  
Author(s):  
Alicja Panas ◽  
Andreas Comouth ◽  
Harald Saathoff ◽  
Thomas Leisner ◽  
Marco Al-Rawi ◽  
...  

Background: Investigations on adverse biological effects of nanoparticles (NPs) in the lung by in vitro studies are usually performed under submerged conditions where NPs are suspended in cell culture media. However, the behaviour of nanoparticles such as agglomeration and sedimentation in such complex suspensions is difficult to control and hence the deposited cellular dose often remains unknown. Moreover, the cellular responses to NPs under submerged culture conditions might differ from those observed at physiological settings at the air–liquid interface. Results: In order to avoid problems because of an altered behaviour of the nanoparticles in cell culture medium and to mimic a more realistic situation relevant for inhalation, human A549 lung epithelial cells were exposed to aerosols at the air–liquid interphase (ALI) by using the ALI deposition apparatus (ALIDA). The application of an electrostatic field allowed for particle deposition efficiencies that were higher by a factor of more than 20 compared to the unmodified VITROCELL deposition system. We studied two different amorphous silica nanoparticles (particles produced by flame synthesis and particles produced in suspension by the Stöber method). Aerosols with well-defined particle sizes and concentrations were generated by using a commercial electrospray generator or an atomizer. Only the electrospray method allowed for the generation of an aerosol containing monodisperse NPs. However, the deposited mass and surface dose of the particles was too low to induce cellular responses. Therefore, we generated the aerosol with an atomizer which supplied agglomerates and thus allowed a particle deposition with a three orders of magnitude higher mass and of surface doses on lung cells that induced significant biological effects. The deposited dose was estimated and independently validated by measurements using either transmission electron microscopy or, in case of labelled NPs, by fluorescence analyses. Surprisingly, cells exposed at the ALI were less sensitive to silica NPs as evidenced by reduced cytotoxicity and inflammatory responses. Conclusion: Amorphous silica NPs induced qualitatively similar cellular responses under submerged conditions and at the ALI. However, submerged exposure to NPs triggers stronger effects at much lower cellular doses. Hence, more studies are warranted to decipher whether cells at the ALI are in general less vulnerable to NPs or specific NPs show different activities dependent on the exposure method.

2015 ◽  
Vol 81 ◽  
pp. 90-99 ◽  
Author(s):  
Yuji Fujitani ◽  
Yutaka Sugaya ◽  
Masanori Hashiguchi ◽  
Akiko Furuyama ◽  
Seishiro Hirano ◽  
...  

Author(s):  
Tuukka Ihantola ◽  
Maija-Riitta Hirvonen ◽  
Mika Ihalainen ◽  
Henri Hakkarainen ◽  
Olli Sippula ◽  
...  

2019 ◽  
Vol 53 (15) ◽  
pp. 9128-9138 ◽  
Author(s):  
Jie Ding ◽  
Jincheng Guo ◽  
Liming Wang ◽  
Yandong Chen ◽  
Bin Hu ◽  
...  

2018 ◽  
Vol 30 (4-5) ◽  
pp. 169-177 ◽  
Author(s):  
Jose Zavala ◽  
Allen D. Ledbetter ◽  
David S. Morgan ◽  
Lisa A. Dailey ◽  
Earl Puckett ◽  
...  

2013 ◽  
Vol 221 ◽  
pp. S138-S139
Author(s):  
S. Troeller ◽  
G. Linsel ◽  
N. Huettig ◽  
M. Bauer ◽  
C. Graebsch ◽  
...  

2020 ◽  
Author(s):  
Mohammadhossein Dabaghi ◽  
Neda Saraei ◽  
Gang Xu ◽  
Abiram Chandiramohan ◽  
Jonas Yeung ◽  
...  

1AbstractIn many biological systems, pH can be used as a parameter to understand and study cell dynamics. However, measuring pH in live cell culture is limited by the sensor ion specificity, proximity to the cell surface, and scalability. Commercially available pH sensors are difficult to integrate into a small-scale cell culture system due to their size and are not cost-effective for disposable use. We made PHAIR - a new pH sensor that uses a micro-wire format to measure pH in vitro human airway cell culture. Tungsten micro-wires were used as the working electrodes, and silver micro-wires with a silver/silver chloride coating were used as a pseudo reference electrode. pH sensitivity, in a wide and narrow range, and stability of these sensors were tested in common standard buffer solutions as well as in culture media of human airway epithelial cells grown at the air-liquid interface in a 24 well cell culture plate. When measuring the pH of cells grown under basal and challenging conditions using PHAIR, cell viability and cytokine responses were not affected. Our results confirm that micro-wires-based sensors have the capacity for miniaturization, and detection of diverse ions while maintaining sensitivity. This suggests the broad application of PHAIR in various biological experimental settings.


Sign in / Sign up

Export Citation Format

Share Document