scholarly journals ENERGY AND EXERGY ANALYSIS OF A CYLINDRICAL HOT WATER STORAGE TANK: EXPERIMENTAL AND CFD ANALYSIS

Author(s):  
Tomas Kropas ◽  
Giedrė Streckienė

Active solar water heating systems typically include hot water storage tanks. The selection of the storage system strongly affects the performance of the entire system. This article presents a detailed analysis of a hot water storage tank during charging and dynamic charging-discharging mode. A numerical model using computational fluid dynamics for the storage tank was developed to investigate the temperature distribution inside of it. Transient thermal analysis was carried using ANSYS Fluent. The numerical model was validated with the experimental results. The energy and exergy analysis as an important tool for the evaluation of the thermal systems quantitatively and qualitatively was performed. The calculation procedures were described. The energy and exergy efficiencies, heat losses were calculated for steady and dynamic processes. Effect of mass flow rate was analysed. The results from parametric analysis showed that charging dynamics reduced the thermocline and efficiency of the hot water storage tank. The dependency of the exergy efficiency of the heat storage tank on the reference environment temperature during the dynamic operation was analysed. Exergy efficiencies for two cities with different climates were compared. This indicated that the higher envi-ronmental temperature gave lower exergy efficiency of the storage tank.

Author(s):  
Ali A. Dehghan ◽  
Mohammad H. Hosni ◽  
S. Hoda Shiryazdi

The thermal performance of a Thermosyphon Domestic Solar Water Heater (DSWH) with a vertical storage tank is investigated experimentally. The system is installed on a roof - top of a four person family house and its thermal characteristics is evaluated by means of carefully measuring the temperature distribution of water inside the storage tank, solar collector flow rate and its inlet and outlet temperatures as well as load/consumption outlet and inlet temperatures and the corresponding water flow rate under a realistic operating conditions. The measurements are conducted every hour starting from morning until late night on a daily basis and continued for about 120 days during August until November 2004. It is seen that thermal stratification is well established inside the tank from 11 AM until 10 PM especially during August to September enabling the tank to provide the necessary amount of hot water at an acceptable temperature. However, thermal stratification is observed to start degrading from mid-night until morning when there is no hot water supply from the collector and due to the diffusion of heat from the top hot water layers to the bottom cold region and conduction through tank’s wall. The thermal behavior of the storage tank is also assessed based on both energy and exergy analysis and its first and second law efficiencies are calculated. It is observed that the storage tank under study has an average first law efficiency of 47.8% and is able to supply the required amount of hot water at a proper temperature. The average second law efficiency of the storage tank is observed to be 28.7% and, although is less than its first low efficiency, but is high enough to ensure that the quality of the hot water supply is well preserved. The proper level of second law efficiency is due to the preservation of the thermal stratification inside the storage tank, leading to supply of hot water at highest possible temperature and hence highest possible energy potential. Experiments are also done for no-load conditions when the storage tank only interacts with the collector, without hot water withdrawal from the tank. It is seen that for no-load condition, thermal stratification continuously develops from morning until around 16 PM after which no noticeable changes in the temperature distribution inside the tank is observed.


2020 ◽  
Vol 143 (1) ◽  
Author(s):  
Azzam Abu-Rayash ◽  
Ibrahim Dincer

Abstract This paper features the integration of two renewable energy sources, making a new trigeneration system for residential applications. The system is primarily powered by solar photovoltaic-thermal (PVT) along with geothermal energy. This trigeneration system consists of a ground source heat pump, solar system, high-grade and low-grade heat exchangers, a heat pump system, and a water storage tank (WST). The objective of this system is to provide the main commodities for residential use including domestic hot water (DHW), electricity, and space heating. The system is analyzed energetically and exergetically using thermodynamic-based concepts. The overall energy and exergy efficiencies of the proposed system are found to be 86.9% and 74.7%, respectively. In addition, the energy and exergy efficiencies of the PVT system are obtained to be 57.91% and 34.19%, respectively. The exergy destructions at the high-grade heat exchanger and the water storage tank add up to 36.9 kW, which makes up 80% of the total exergy destruction of the system. Additionally, parametric studies are conducted to evaluate the degree of impact that various important parameters have on the overall system performance.


Energies ◽  
2021 ◽  
Vol 14 (15) ◽  
pp. 4470
Author(s):  
Yikai Wang ◽  
Yifan He ◽  
Yulong Song ◽  
Xiang Yin ◽  
Feng Cao ◽  
...  

Given the large demand nowadays for domestic hot water, and its impact on modern building energy consumption, air source transcritical CO2 heat pumps have been extensively adopted for hot water production. Since their system efficiency is limited by significant irreversibility, a CO2-based mixture could offer a promising drop-in technology to overcome this deficiency without increasing system complexity. Although many CO2 blends have been studied in previously published literature, little has been presented about the CO2/R32 mixture. Therefore, a proposed mixture for use in transcritical CO2 heat pumps was analyzed using energy and exergy analysis. Results showed that the coefficient of performance and exergy efficiency variation displayed an “M” shape trend, and the optimal CO2/R32 mixture concentration was determined as 0.9/0.1 with regard to flammability and efficiency. The irreversibility of the throttling valve was reduced from 0.031 to 0.009 kW⋅kW−1 and the total irreversibility reduction was more notable with ambient temperature variation. A case study was also conducted to examine domestic hot water demand during the year. Pure CO2 and the proposed CO2 blend were compared with regard to annual performance factor and annual exergy efficiency, and the findings could provide guidance for practical applications in the future.


Energies ◽  
2021 ◽  
Vol 14 (16) ◽  
pp. 4741
Author(s):  
María Gasque ◽  
Federico Ibáñez ◽  
Pablo González-Altozano

This paper demonstrates that it is possible to characterize the water temperature profile and its temporal trend in a hot water storage tank during the thermal charge process, using a minimum number of thermocouples (TC), with minor differences compared to experimental data. Four experimental tests (two types of inlet and two water flow rates) were conducted in a 950 L capacity tank. For each experimental test (with 12 TC), four models were developed using a decreasing number of TC (7, 4, 3 and 2, respectively). The results of the estimation of water temperature obtained with each of the four models were compared with those of a fifth model performed with 12 TC. All models were tested for constant inlet temperature. Very acceptable results were achieved (RMSE between 0.2065 °C and 0.8706 °C in models with 3 TC). The models were also useful to estimate the water temperature profile and the evolution of thermocline thickness even with only 3 TC (RMSE between 0.00247 °C and 0.00292 °C). A comparison with a CFD model was carried out to complete the study with very small differences between both approaches when applied to the estimation of the instantaneous temperature profile. The proposed methodology has proven to be very effective in estimating several of the temperature-based indices commonly employed to evaluate thermal stratification in water storage tanks, with only two or three experimental temperature data measurements. It can also be used as a complementary tool to other techniques such as the validation of numerical simulations or in cases where only a few experimental temperature values are available.