scholarly journals Energy Efficient Glazed Office Building Envelope Solutions for Different European Climates

2017 ◽  
Vol 9 (4) ◽  
pp. 470-481
Author(s):  
Marco Scanferla ◽  
Violeta Motuzienė

The aim of this study is to show the critical aspects of a completely glazed high rise office building from an energy efficiency point of view in different European climates. The achievable consumptions and the most influential parameters such as glazing U-value, VT/SHGC and shading and their optimal values were investigated. The study has been carried out for a theoretical office building in Italy and Lithuania, representatively of a southern and northern EU climate. The building chosen is representative of all the glazed-simple shape buildings and the analysis of the entirety of the building enables a clear and im-mediate outcome of global consumptions. Number of DesignBuilder simulations were performed and the annual consumptions are summed with the primary energy criteria. Results show the critical aspects of 100% WWR buildings: in the coldest climate the main problem is the huge surface of relatively high glass U-value compared with standard walls, while in the warmer one the main efforts need to be done to avoid the summer overheating caused by incoming solar radiation. Finally, it is shown that it is difficult to lower the overall primary energy consumptions below 130 and 140 kWh/m2a for North-Italy and Lithuania locations respectively. The analysis is focused only in the envelope parameter, thus it is not included renewable energy systems, which can generate higher energy efficiencies.

2019 ◽  
Vol 1 (1) ◽  
pp. 106
Author(s):  
Amirul Amin Ismail ◽  
Azman Zainonabidin

In the Eleventh Malaysia Plan, Malaysia will be pioneering a sustainable city development by retrofitting all Government buildings to be energy efficient. Overall Thermal Transfer Value (OTTV) is a measuring tool of thermal efficiency for building envelope. A case study on iconic 4G11 Tower is carried out to determine the possibility of improving OTTV assessment for existing high-rise office building thus enhance the building’s overall efficiency. Through this exercise, several variables influence the OTTV score such as U-Value, Shading Coefficient (SC) and Window-to-Wall Ratio (WWR). Characterised by Baseline Design, MS1525 Design and Platinum Design, this will be a precedent of OTTV assessment for high-rise office building typology. 


Energies ◽  
2019 ◽  
Vol 12 (5) ◽  
pp. 895 ◽  
Author(s):  
Ilaria Ballarini ◽  
Giovanna De Luca ◽  
Argun Paragamyan ◽  
Anna Pellegrino ◽  
Vincenzo Corrado

Directive 2010/31/EU promotes the refurbishment of existing buildings to change them into nearly zero-energy buildings (nZEBs). Within this framework, it is of crucial importance to guarantee the best trade-off between energy performance and indoor environmental quality (IEQ). The implications of a global refurbishment scenario on thermal and visual comfort are assessed in this paper pertaining to an existing office building. The retrofit actions applied to achieve the nZEB target consist of a combination of envelope and technical building systems refurbishment measures, involving both HVAC and lighting. Energy and comfort calculations were carried out through dynamic simulation using Energy Plus and DIVA, for the thermal and visual performance assessments, respectively. The results point out that energy retrofit actions on the building envelope would lead to significant improvements in the thermal performance, regarding both energy savings (−37% of the annual primary energy for heating) and thermal comfort. However, a daylighting reduction would occur with a consequent higher electricity demand for lighting (36%). The research presents a detailed approach applicable to further analyses aimed at optimizing the energy efficiency measures in order to reduce the imbalance between visual and thermal comfort and to ensure the best performance in both domains.


Materials ◽  
2021 ◽  
Vol 14 (6) ◽  
pp. 1501
Author(s):  
Asier Salicio-Paz ◽  
Ixone Ugarte ◽  
Jordi Sort ◽  
Eva Pellicer ◽  
Eva García-Lecina

Univariate and multivariate optimizations of a novel electroless nickel formulation have been carried out by means of the Taguchi method. From the compositional point of view, adjustment of the complexing agent concentration in solution is crucial for fine-tuning free Ni2+ ions concentration and, in turn, the mechanical properties of the resulting coatings. The Ni (II) concentration and the pH are the main parameters which help restrict the incorporation of phosphorous into the Ni layers. On the other hand, the stirring rate, the pH and the reducing agent concentration are the most influential parameters for the corrosion resistance of the coatings. Multivariate optimization of the electrolyte leads to a set of optimized parameters in which the mechanical properties (hardness and worn volume) of the layers are similar to the optimal values achieved in the univariate optimization, but the corrosion rate is decreased by one order of magnitude.


Energies ◽  
2020 ◽  
Vol 13 (11) ◽  
pp. 3020 ◽  
Author(s):  
Michaela Detsi ◽  
Aris Manolitsis ◽  
Ioannis Atsonios ◽  
Ioannis Mandilaras ◽  
Maria Founti

This paper assesses energy savings in terms of heating, cooling, and artificial lighting achieved in an office building with a high Window to Wall Ratio (WWR), located in Athens and Stockholm. Six different configurations of triple pane windows combining thermochromic, electrochromic, and low-e coatings in Insulated Glass Units (IGUs) are examined to quantify the potential of increasing energy savings in office buildings. The combination of electrochromic and thermochromic layers on the outer pane of the triple IGU, achieved an 18.5% and 8.1% reduction in annual primary energy use for Athens and Stockholm, respectively. The used switching strategy ensured the visual comfort of the employees and provided adequate daylight in both cases. It was found that in Stockholm the cooling system can be downsized considerably, achieving important cost reduction in the HVAC system. The analysis also takes into account the reduction of thermal storage in the building envelope due to the switchable windows. This reduction is beneficial in the case of Athens, but it can reduce energy savings in Stockholm. Therefore, for colder climates, it is important to increase window heat gains through the development of layers with higher g-value in the clear state and through the application of appropriate switching strategies.


1982 ◽  
Vol 26 (2) ◽  
pp. 132-136
Author(s):  
A.F. Emery ◽  
D.R. Heerwagen ◽  
C.F. Kippenhan

How the building envelope may affect occupant thermal comfort has been investigated. Alternative envelopes for a high-rise office building, which were chosen to comply with the City of Seattle Energy Conservation Code, were employed. The thermal comfortability of the resulting office settings was studied using the simulation program OFFICE which employs the Fanger Comfort Equation.


2020 ◽  
pp. 50-64
Author(s):  
Kuladeep Kumar Sadevi ◽  
Avlokita Agrawal

With the rise in awareness of energy efficient buildings and adoption of mandatory energy conservation codes across the globe, significant change is being observed in the way the buildings are designed. With the launch of Energy Conservation Building Code (ECBC) in India, climate responsive designs and passive cooling techniques are being explored increasingly in building designs. Of all the building envelope components, roof surface has been identified as the most significant with respect to the heat gain due to the incident solar radiation on buildings, especially in tropical climatic conditions. Since ECBC specifies stringent U-Values for roof assembly, use of insulating materials is becoming popular. Along with insulation, the shading of the roof is also observed to be an important strategy for improving thermal performance of the building, especially in Warm and humid climatic conditions. This study intends to assess the impact of roof shading on building’s energy performance in comparison to that of exposed roof with insulation. A typical office building with specific geometry and schedules has been identified as base case model for this study. This building is simulated using energy modelling software ‘Design Builder’ with base case parameters as prescribed in ECBC. Further, the same building has been simulated parametrically adjusting the amount of roof insulation and roof shading simultaneously. The overall energy consumption and the envelope performance of the top floor are extracted for analysis. The results indicate that the roof shading is an effective passive cooling strategy for both naturally ventilated and air conditioned buildings in Warm and humid climates of India. It is also observed that a fully shaded roof outperforms the insulated roof as per ECBC prescription. Provision of shading over roof reduces the annual energy consumption of building in case of both insulated and uninsulated roofs. However, the impact is higher for uninsulated roofs (U-Value of 3.933 W/m2K), being 4.18% as compared to 0.59% for insulated roofs (U-Value of 0.33 W/m2K).While the general assumption is that roof insulation helps in reducing the energy consumption in tropical buildings, it is observed to be the other way when insulation is provided with roof shading. It is due to restricted heat loss during night.


2020 ◽  
Vol 10 (13) ◽  
pp. 4489
Author(s):  
Zakaria Che Muda ◽  
Payam Shafigh ◽  
Norhayati Binti Mahyuddin ◽  
Samad M.E. Sepasgozar ◽  
Salmia Beddu ◽  
...  

The increasing need for eco-friendly green building and creative passive design technology in response to climatic change and global warming issues will continue. However, the need to preserve and sustain the natural environment is also crucial. A building envelope plays a pivotal role in areas where the greatest heat and energy loss often occur. Investment for the passive design aspect of building envelopes is essential to address CO 2 emission. This research aims to explore the suitability of using integral-monolithic structural insulation fibre-reinforced lightweight aggregate concrete (LWAC) without additional insulation as a building envelope material in a high-rise residential building in the different climatic zones of the world. Polypropylene and steel fibres in different dosages were used in a structural grade expanded clay lightweight aggregate concrete. Physical and thermal properties of fibre reinforced structural LWAC, normal weight concrete (NWC) and bricks were measured in the lab. The Autodesk@Revit-GBS simulation program was implemented to simulate the energy consumption of a 29-storey residential building with shear wall structural system using the proposed fibre-reinforced LWAC materials. Results showed that energy savings between 3.2% and 14.8% were incurred in buildings using the fibre-reinforced LWAC across various climatic regions as compared with traditional NWC and sand-cement brick and clay brick walls. In conclusion, fibre-reinforced LWAC in hot-humid tropical and temperate Mediterranean climates meet the certified Green Building Index (GBI) requirements of less than 150 kW∙h∙m−2. However, in extreme climatic conditions of sub-arctic and hot semi-arid desert climates, a thicker wall or additional insulation is required to meet the certified green building requirements. Hence, the energy-saving measure is influenced largely by the use of fibre-reinforced LWAC as a building envelope material rather than because of building orientation.