scholarly journals Font Size: Compound Pollen Protein Nutrient Increases Serum Albumin in Cirrhotic Rats

2011 ◽  
Author(s):  
Hong Bo Shi
2009 ◽  
Vol 11 (2) ◽  
Author(s):  
Eystein Glattre ◽  
A. Engeland ◽  
A. T. Høstmark ◽  
E. Jellum

<strong><span style="font-family: TimesNewRomanPS-BoldMT;"><font face="TimesNewRomanPS-BoldMT"><p align="left"> </p></font></span><p align="left"><span style="font-size: x-small; font-family: TimesNewRomanPS-BoldMT;"><span style="font-size: x-small; font-family: TimesNewRomanPS-BoldMT;">NORSK SAMMENDRAG</span></span></p></strong><span style="font-size: x-small; font-family: TimesNewRomanPSMT;"><span style="font-size: x-small; font-family: TimesNewRomanPSMT;"><p align="left">Flere epidemiologiske undersøkelser fra 1980- og 1990-årene har funnet en invers assosiasjon mellom salbuminnivået</p><p align="left">og sykelighet/dødelighet av kreft. I utforskningen av skjoldkjertelkreftens etiologi og patogenese</p><p align="left">ble det derfor ansett som viktig å finne og bestemme styrken av en slik sammenheng når det gjelder</p><p align="left">skjoldkjertelkreft. Derfor ble alle med tilstrekkelig mengde serum deponert i Janusbanken og som senere i</p><p align="left">perioden 1973-1994, ifølge Kreftregisterets database, hadde fått skjoldkjertelkreft, identifisert – i alt 118</p><p align="left">tilfeller. For hvert tilfelle ble det tilfeldig valgt ut tre friske kontroller med serum i Janus. Kontrollene ble</p><p align="left">matchet mot pasientene hva gjelder kjønn, alder, bostedsfylke og serums lagringstid. Etter dette sto man</p><p align="left">igjen med 114 tilfeller (78 papillære karsinomer, 19 follikulære og 17 av andre histologiske typer) og 333</p><p align="left">kontroller. Albumin i serum ble bestemt med bromkresolgrønt-metoden og fri fettsyrer ble bestemt med en</p><p align="left">enzymatisk metode. Resultatene av denne populasjonsbaserte pasient-kontroll studien ble i korthet at man</p><p align="left">etter justering for fri fettsyrer ikke fant noen sammenheng mellom s-albumin og kreftrisiko for tilfeller der</p><p align="left">serum var tatt mer enn 6,6 år før diagnose. For serum tatt mindre enn 6,6 år før diagnose var det derimot en</p><p align="left">mulig positiv assosiasjon for de papillære karsinomene og en sannsynlig positiv assosiasjon for de follikulære</p><p align="left">karsinomene. Man fant altså ingen invers assosiasjon mellom s-albumin og skjoldkjertelkreft. I en</p><p>kortfattet diskusjon omtales noen konfunderingsfaktorer som kan ha bidratt til resultatet.</p></span></span>


2018 ◽  
Vol 28 (3) ◽  
pp. 247 ◽  
Author(s):  
Achadiah Rachmawati ◽  
Ismaya Ismaya ◽  
Budi Prasetyo Widyobroto ◽  
Sigit Bintara ◽  
Trinil Susilawati

<span class="fontstyle0">Artificial insemination (AI) in cattle using Ongole Cross Breed liquid semen with cauda epidydymal plasma-2 (CEP-2) diluent+0.6% Bovine Serum Albumin (BSA) aimed to improve the genetic quality of livestock with high sperm motility on beef cows. Addition of BSA as extracellular cryoprotectant to support egg yolk function to prevent membrane damage caused by cold shock during cold storage. This research was conducted in Tumpang, Pakis, and Singosari Sub-district, Malang Regency using 38 cows that inseminated using frozen semen of Limousine and Simmental breeds as control (19 cows) and liquid semen with CEP-2 + 0.6% BSA as a treatment (19 cows). The reproductive parameters were Non Return Rate (NRR), Service per Conception (S/C) and Conception Rate (CR). Data were analyzed descriptively and continued by chi-square test. The results showed that insemination using frozen and liquid semen did not affect the success rate of AI in beef cows. The NRR</span><span class="fontstyle0" style="font-size: 7pt;">43-63</span><span class="fontstyle0"> value of frozen was 89.40% and liquid semen was 78.94%; the CR value of frozen semen was 84.21% and liquid semen was 57.89%; and the S/C value of frozen semen was 1.21 and liquid semen was 1.42. The conclusions of the study were the values of NRR</span><span class="fontstyle0" style="font-size: 7pt;">43-63</span><span class="fontstyle0">, CR and S/C of frozen higher than liquid<br />semen.</span>


Author(s):  
G. D. Gagne ◽  
M. F. Miller

We recently described an artificial substrate system which could be used to optimize labeling parameters in EM immunocytochemistry (ICC). The system utilizes blocks of glutaraldehyde polymerized bovine serum albumin (BSA) into which an antigen is incorporated by a soaking procedure. The resulting antigen impregnated blocks can then be fixed and embedded as if they are pieces of tissue and the effects of fixation, embedding and other parameters on the ability of incorporated antigen to be immunocyto-chemically labeled can then be assessed. In developing this system further, we discovered that the BSA substrate can also be dried and then sectioned for immunolabeling with or without prior chemical fixation and without exposing the antigen to embedding reagents. The effects of fixation and embedding protocols can thus be evaluated separately.


1969 ◽  
Vol 08 (01) ◽  
pp. 15-21 ◽  
Author(s):  
K. E. Scheer ◽  
J. Heep ◽  
W. Maier-Borst ◽  
W. J. Lorenz ◽  
H. Sinn ◽  
...  

ZusammenfassungNach tierexperimentellen Voruntersuchungen wurde die Placentographie mit trägerfreiem 113Inm -HSA als klinische Methode eingeführt. Vor Amniocentesen und bei Verdacht auf Placenta praevia werden Placentographien geschrieben. Den Schwangeren wird eine Aktivität von 500 μCi in die Cubitalvene injiziert. Die der Aktivität entsprechende Indiummenge ist kleiner als 0,1 ng. Die fetale Strahlenbelastung liegt unter lOmrad. Bei Anwendung von 113Inm-HSA entfällt eine Blockade der mütterlichen und fetalen Schilddrüsen. Die genaue Abgrenzung einer Placenta praevia wird nicht durch eine Blasenaktivität beeinträchtigt.Es wurden bisher 19 Placentalokalisationen durchgeführt. In allen Fällen konnte der Placentasitz eindeutig festgestellt werden. Bedingt durch die lange Liegezeit beim Aufnehmen eines Szintigramms kam es in zwei Fällen zu einem Vena-Cava-Kompressions-Syndrom. Zur Verhinderung dieser klinischen Zwischenfälle werden inzwischen Placentographien mit der Anger-Kamera aufgenommen. Mit Hilfe des divergierenden Kollimators konnte der gesamte Abdominalbereich erfaßt werden. Die Aufnahmezeit konnte auf 7 — 10 Minuten verkürzt werden. Die intravenöse injizierte Aktivität betrug bei dieser Methode ebenfalls 500 μCi. Der diagnostische Aussagewert der Kamerabilder ist szintigraphischen Aufnahmen gleichwertig.


Sign in / Sign up

Export Citation Format

Share Document