Experimental Investigation on Composite Circular Steel Columns - Taguchi’s Approach

2011 ◽  
Vol 105-107 ◽  
pp. 1742-1750
Author(s):  
N. S. Kumar ◽  
Sameera Simha T.P.

Composite circular steel tubes- with and without epoxy infill for three different grades of concrete are tested for ultimate load capacity and axial shortening , under axial monotonic loading for compression. Steel tubes are compared for different lengths, cross sections and thickness. Specimens were tested separately after adopting Taguchi’s L9 (Latin Squares) Orthogonal array in order to save the initial experimental cost on number of specimens and experimental duration. DOE (Design of Experiment) approach was adopted. Results were generated using Taguchi’s method-a new technique to get mean effects plot. Analysis was carried out using ANOVA (Analysis of Variance) technique with the assistance of Mini Tab v15- a statistical soft tool. Results were verified after conducting preliminary nine combination experiments as per L9 orthogonal array and linear regression models were developed. Comparison for predicted and experimental output is obtained from linear regression plots. To know the implications of different factors on circular composite columns with and without epoxy, surface contours were also generated. From this research study it is concluded that ,Regression models which were developed with minimum number of experiments based on Taguchi’s method predicted the axial load carrying capacity very well and reasonably well for at ultimate point. Cross sectional area of steel tube has most significant effect on ultimate load carrying capacity. Also it is observed that, as length of steel tube increased- load carrying capacity decreased.

Author(s):  
Shaik Heena ◽  
Syed Rizwan ◽  
A.B.S. Dadapeer

Concrete filled steel tubes (CFST) member have many advantages compared with the ordinary structural member made of steel or reinforced concrete. One of the main advantages is the interaction between the steel tube and concrete. Concrete delays the steel tube’s local buckling, whereas the steel tube confines the concrete and thereby increases the concrete’s strength. CFSTs are economical and permit rapid construction because the steel tube serves as formwork and reinforcement to the concrete fill, negating the need for either. The deformation capacity of the system is increased by the combined action of the concrete fill with the thin, ductile steel tube. The concrete fill significantly increases inelastic deformation capacity and the compressive stiffness and load capacity of the CFST member. In building construction concrete filled steel tubes are very widely used for columns in combination with steel or reinforced concrete beam. In this work totally 9 specimens were tested out of which 3 specimens were empty steel tubes and remaining 6 specimens were concrete filled with different bonding techniques. As it is prefabricated time consumption will be less in construction practice and due to confinement more ductility is expected which is very useful in earthquake resistant structures. Load carrying capacity of CFST almost doubled in comparison with empty steel tubes. Ultimate load carrying capacity of concrete filled steel tube beams almost doubled compared to empty steel tubes. Compared to empty steel tubes, strength increase of 67.19%, 97.48% and 114.84% was observed in normal CFST, CFST with sand blasting and CFST with diagonal shear connector beams respectively. Average ultimate load of EST was 105.66kN whereas average load of CFSTB, CFSTBWSB and CFSTBWDSC was 176.66, 208.66 and 227kN respectively. The maximum load was taken by the specimen CFSTBWDSC – 03 which was 231kN, it may be because of presence of diagonal shear connector inside the tube.


2010 ◽  
Vol 163-167 ◽  
pp. 2224-2233
Author(s):  
Li Zhong Jiang ◽  
Wang Bao Zhou ◽  
Jing Jing Qi

The paper presents a numerical method for calculating the load-deformation response and ultimate load carrying capacity of Concrete Filled Steel Tubular (CFST) latticed columns A half-wave sinusoidal function is assumed for the deflected shape of the column. The effect of confinement and shear deformation are included in the analysis, and the corresponding equilibrium equation is established. The method applies to eccentrically loaded compression members bent in single curvature. Unequal end eccentricities can be considered. Test results are reported for seventeen four latticed column specimens with varying end eccentricities and slenderness ratios. The obtained results show that eccentricity has significant effect on the bearing capacity of specimen, and the slenderness ratio also has some influence. The diagonal lacing bars remained in the elastic state during the entire load range. When specimens go into the nonlinear stage, Poisson's ratio of the near-load steel tube increases and a significant confinement effect can be observed. For the far-load steel tube, confinement effect does not occur to a significant extent. Specimen failure is due to overall instability except in the case of several individual short columns. Good agreement was found between the theoretical and experimental results using the numerical method developed in the paper. The proposed numerical method is shown to be more accurate than the current method presented in the Chinese code.


2018 ◽  
Vol 2018 ◽  
pp. 1-16 ◽  
Author(s):  
Rajinder Ghai ◽  
Prem Pal Bansal ◽  
Maneek Kumar

There is a common phenomenon of shear failure in RCC beams, especially in old buildings and bridges. Any possible strengthening of such beams is needed to be explored that could strengthen and make them fit for serviceable conditions. The present research has been made to determine the performance of predamaged beams strengthened with three-layered wire mesh polymer-modified ferrocement (PMF) with 15% styrene-butadiene-rubber latex (SBR) polymer. Forty-eight shear-designed and shear-deficient real-size beams were used in this experimental work. Ultimate shear load-carrying capacity of control beams was found at two different shear-span (a/d) ratios 1 and 3. The sets of remaining beams were loaded with different predetermined damage levels of 45%, 75%, and 95% of the ultimate load values and then strengthened with 20 mm thick PMF. The strengthened beams were then again tested for ultimate load-carrying capacity by conducting the shear load test at a/d = 1 and 3. As a result, the PMF-strengthened beams showed restoration and enhancement of ultimate shear load-carrying capacity by 5.90% to 12.03%. The ductility of strengthened beams was improved, and hence, the corresponding deflections were prolonged. On the other hand, the cracking pattern of PMF-strengthened beams was also improved remarkably.


Materials ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 3468
Author(s):  
Zbigniew Kolakowski ◽  
Andrzej Teter

The phenomena that occur during compression of hybrid thin-walled columns with open cross-sections in the elastic range are discussed. Nonlinear buckling problems were solved within Koiter’s approximation theory. A multimodal approach was assumed to investigate an effect of symmetrical and anti-symmetrical buckling modes on the ultimate load-carrying capacity. Detailed simulations were carried out for freely supported columns with a C-section and a top-hat type section of medium lengths. The columns under analysis were made of two layers of isotropic materials characterized by various mechanical properties. The results attained were verified with the finite element method (FEM). The boundary conditions applied in the FEM allowed us to confirm the eigensolutions obtained within Koiter’s theory with very high accuracy. Nonlinear solutions comply within these two approaches for low and medium overloads. To trace the correctness of the solutions, the Riks algorithm, which allows for investigating unsteady paths, was used in the FEM. The results for the ultimate load-carrying capacity obtained within the FEM are higher than those attained with Koiter’s approximation method, but the leap takes place on the identical equilibrium path as the one determined from Koiter’s theory.


2018 ◽  
Vol 22 (7) ◽  
pp. 1554-1565 ◽  
Author(s):  
Jianwei Tu ◽  
Kui Gao ◽  
Lang He ◽  
Xinping Li

At present, extensive studies have been conducted relative to the topic of fiber-reinforced polymer(FRP)- reinforced concrete (RC) flexural members, and many design methods have also been introduced. There have, however, been few studies conducted on the topic of FRP-RC compression members. In light of this, eight glass-fiber-reinforced polymer (GFRP)-RC square columns (200×200×600 mm) were tested in order to investigate their axial compression performance. These columns were reinforced with GFRP longitudinal reinforcement and confined GFRP stirrup. These experiments investigated the effects of the longitudinal reinforcement ratio, stirrup configuration (spirals versus hoops) and spacing on the load-carrying capacity and failure modes of GFRP-RC rectangular columns. The test results indicate that the load-carrying capacity of longitudinal GFRP bars accounted for 3%-7% of the ultimate load-carrying capacity of the columns. The ultimate load-carrying capacity of RC columns confined with GFRP spirals increased by 0.8%-1.6% with higher ductility, compared to GFRP hoops. Reducing the stirrup spacing may prevent the buckling failure of the longitudinal bars and increase the ductility and load-carrying capacity of the GFRP-RC columns. It has been found that setting the GFRP compressive strength to 35% of the GFRP maximum tensile strength yields a reasonable estimate of ultimate load-carrying capacity of GFRP-RC columns.


2003 ◽  
Vol 1845 (1) ◽  
pp. 191-199 ◽  
Author(s):  
Ondrej Kalny ◽  
Robert J. Peterman ◽  
Guillermo Ramirez ◽  
C. S. Cai ◽  
Dave Meggers

Stiffness and ultimate load-carrying capacities of glass fiber-reinforced polymer honeycomb sandwich panels used in bridge applications were evaluated. Eleven full-scale panels with cross-section depths ranging from 6 to 31.5 in. (152 to 800 mm) have been tested to date. The effect of width-to-depth ratio on unit stiffness was found to be insignificant for panels with a width-to-depth ratio between 1 and 5. The effect of this ratio on the ultimate flexural capacity is uncertain because of the erratic nature of core-face bond failures. A simple analytical formula for bending and shear stiffness, based on material properties and geometry of transformed sections, was found to predict service-load deflections within 15% accuracy. Although some factors influencing the ultimate load-carrying capacity were clearly identified in this study, a reliable analytical prediction of the ultimate flexural capacity was not attained. This is because failures occur in the bond material between the outer faces and core, and there are significant variations in bond properties at this point due to the wet lay-up process, even for theoretically identical specimens. The use of external wrap layers may be used to shift the ultimate point of failure from the bond (resin) material to the glass fibers. Wrap serves to strengthen the relatively weak core–face interface and is believed to bring more consistency in determining the ultimate load-carrying capacity.


1987 ◽  
Vol 2 (3) ◽  
pp. 77-80 ◽  
Author(s):  
Marvin R. Pyles ◽  
Joan Stoupa

Abstract In order to quantify the stump anchor capacity of small second-growth Douglas-fir (Pseudotsuga menziesii [Mirb]. Franco) trees, load tests to failure were conducted on 18 stumps from trees 7 to 16.5 in dbh. The tests produced ultimate loads that varied as the square of the tree diameter. However, the ultimate load typically occurred at stump system deformations that were far in excess of that which would be considered failure of a stump anchor. A hyperbolic equation was used to describe the load-deformation behavior of each stump tested and was generalized to describe all the test results. West. J. Appl. For. 2(3):72-80, July 1987.


2017 ◽  
Vol 26 (6) ◽  
pp. 096369351702600
Author(s):  
Min Hou ◽  
Jiangfeng Dong ◽  
Lang Li ◽  
Shucheng Yuan ◽  
Qingyuan Wang

In order to make an effective use of the recycled aggregate concrete (RAC), a total of six steel tube RAC columns and six basalt fiber (BF) reinforced RAC columns, including six columns that were externally strengthened with aramid fiber reinforced polymer (AFRP) sheets, were fabricated and tested. This were to provide a strengthening solution to upgrade the load carrying capacity, ductility and rigidity of the RAC filled steel tube columns. Besides, the recycled coarse aggregate (RCA) replacement ratios for production of RAC was analyzed. The results show that the load carrying capacity and ultimate displacements of the RAC filled ST columns could be improved greatly by adding of basalt fiber, especially for the specimens with 50% and 100% RCA replacement ratio. The similar result was also found for the specimens strengthened with AFRP reinforcement, along with the stiffness of the columns were enhanced obviously. Moreover, the highest improving on the load carrying capacity, stiffness and ultimate displacement was found in the specimens both reinforced by adding of BF and strengthening of AFRP. However, the failure modes of the specimens with BF reinforced RAC gave a higher deformability than the one with AFRP strengthening arrangement.


2019 ◽  
Vol 22 (13) ◽  
pp. 2755-2770
Author(s):  
Fuyun Huang ◽  
Yulong Cui ◽  
Rui Dong ◽  
Jiangang Wei ◽  
Baochun Chen

When casting wet concrete into hollow steel tubular arch during the construction process of a concrete-filled steel tubular arch bridge, an initial stress (due to dead load, etc.) would be produced in the steel tube. In order to understand the influence of this initial stress on the strength of the concrete-filled steel tubular arch bridge, a total of four single tubular arch rib (bare steel first) specimens (concrete-filled steel tubular last) with various initial stress levels were constructed and tested to failure. The test results indicate that the initial stress has a large influence on the ultimate load-carrying capacity and ductility of the arch structure. The high preloading ratio will reduce significantly the strength and ductility that the maximum reductions are over 25%. Then, a finite element method was presented and validated using the test results. Based on this finite element model, a parametric study was performed that considered the influence of various parameters on the ultimate load-carrying capacity of concrete-filled steel tubular arches. These parameters included arch slenderness, rise-to-span ratio, loading method, and initial stress level. The analysis results indicate that the initial stress can reduce the ultimate loading capacity significantly, and this reduction has a strong relationship with arch slenderness and rise-to-span ratio. Finally, a method for calculating the preloading reduction factor of ultimate load-carrying capacity of single concrete-filled steel tubular arch rib structures was proposed based on the equivalent beam–column method.