Characteristics of Nutrients Removal from Stored Algae Anaerobic Biogas Slurry in Artificial Aquatic Vegetable Wetlands

2012 ◽  
Vol 178-181 ◽  
pp. 777-782 ◽  
Author(s):  
Guang Can Zhu ◽  
Jin Wei Zhao ◽  
Xuan Xuan Zhao ◽  
Xi Wu Lu

We constructed artificial aquatic water spinach wetland and studied its characteristics on removing nutrients from stored algae anaerobic biogas slurry. The results showed that, when the hydraulic loading was less than 0.10m3/(m2•d), the removal efficiencies of TN and TP were more than 95%, and the effluent quality met class A standard of Urban sewage treatment plant emission standards(GB18918-2002). The uptake rates of water spinach on TN and TP were 1.31 mg/(g•d) and 0.23mg/(g•d). The uptake by water spinach was the main pathway for artificial wetlands to remove nitrogen and phosphorus. The TN and TP removed by plant uptake accounted for 60% and 98% of the total removal, respectively. The nitrification potential of artificial aquatic vegetable wetland decreased gradually along the flow direction with increasing declination extent, while the denitrification potential first increased and then decreased.

1995 ◽  
Vol 32 (3) ◽  
pp. 79-86
Author(s):  
Louis Vandevenne

The sewage treatment plant studied, located in a rural area, is designed to treat the wastewater for a population of 650. The station functions in accordance with the principle of natural lagoons via artificial wetlands combining macrophytes and microphytes lagoons arranged in series. The overall surface area including the primary lagoon gives rise to a specific load of 6 m2/inhabitant. Both the primary and secondary treatments produce a very good water quality in accordance with the conventional parameters (SS, Suspended Solids; BOD5, the Biological Oxygen Demand over a 5 day period; COD, the Chemical Oxygen Demand). The tertiary purification of the nitrogen and phosphorus does not give as good results as expected, respectively 42% and 35% removal; very little better than those of a conventional installation. The tertiary quality standard appears not to be attainable since the successive biological mechanisms carrying out the elimination process are followed by a release of the pollutants and an insufficient elimination (plant exportation) by the macrophytes. The design and management of the macrophytes basins is relatively tricky, particularly with respect to the removal of weeds and the regulation of the water level in the macrophytes basins.


Ecotoxicology ◽  
2016 ◽  
Vol 25 (10) ◽  
pp. 1849-1857 ◽  
Author(s):  
Dalel Belhaj ◽  
Khaled Athmouni ◽  
Bouthaina Jerbi ◽  
Monem Kallel ◽  
Habib Ayadi ◽  
...  

2011 ◽  
Vol 11 (3) ◽  
pp. 97-103
Author(s):  
Jerzy Jańczak ◽  
Wojciech Maślanka ◽  
Kamil Nowiński

Causes of polytrophism of three lakes in the Wdzydze Landscape ParkIn the lakes Cheb and Słupino, located in the Wdzydze Landscape Park the quality of waters has been deteriorating in recent years. In the hydrologic year 2009 the quality of water was examined three times. Monthly measurements on the lake inflows and outflows were carried out 12 times to determine biogenic loads. In 2010 the supplementary measurements of biogenic loads were taken in the streams five times. According to Vollenweider's criterion, the loads of nitrogen and phosphorus compounds are too big, the heaviest to Lake Cheb. The discharge from the new sewage treatment plant is directed by the inflows into this lake. A similar situation takes place in the inflow to Lake Schodno. Paradoxically, in some catchments the construction of the sewage treatment plant may result in the deterioration of lake water quality.


2013 ◽  
Vol 385-386 ◽  
pp. 857-861
Author(s):  
Xiao Ping Huang ◽  
Qi Xing Qing

On the basis of the computerized technological process control of sewage treatment in a urban sewage treatment plant in the Zone of Nanning, the author had brought forward a plan of PROFIBUS that based on automatic control system for sewage treatment, and designed the automatic control system diagram and the PROFIBUS network diagram for sewage treatment plant. At the same time, the author also made a study of techniques to control the sewage aeration, which was the most difficult problem in sewage treatment process. The fuzzy controller could indicate the changes of the water quality in treated sewage, effectively controlled the volume of aeration and then cut down the operation costs,it had produced good economic and social benefits.


2013 ◽  
Vol 361-363 ◽  
pp. 601-605
Author(s):  
Ji Ku Zhang ◽  
Yang Yang Li ◽  
Chen Zhang ◽  
Yan Bin Yang

By treating the secondary effluent of Sanbaotun sewage treatment plant in Fushun with the CS type UV Sterilizer, the experiment researches the influence on the removal rate which includes the factors of turbidity, chromaticity, initial E.coli concentration of raw water, UV dose. The results show that the turbidity does not influence on UV disinfection efficiency with the turbidity from 1.5NTU to 3.8NTU. In the low-dose UV disinfection process, the influent sewage turbidity should under 4NTU to ensure the disinfection efficiency. Low chromaticity does not affect the UV disinfection efficiency, with the influent sewage chromaticity is under 15 degrees.The initial E. coli has a certain impact on little doses of UV disinfection with the concentration from 175 × 104 A/ L to 230 × 104 A/ L, no impact on high doses of UV disinfection。


Author(s):  
Andrea Lanzini ◽  
Pierluigi Leone ◽  
Massimo Santarelli

A biogas coming from anaerobic digestion of urban sewage has been used to feed a SOFC planar anode-supported cell. The sewage is produced from the urban area of Torino (IT), and eventually collected and treated by SMAT (the municipal company managing the potable and waste water of the city). The biogas is produced by the thermophilic fermentation of the sludge which remains after the several treatments the sewage goes through in the above-mentioned plant. The biogas is of a high quality: it has on average a a methane content around 65% (the balance being essentially CO2), and the only significant impurity measured is H2S in a range of 70–80 ppm. The as-produced biogas has been used for feeding a planar Ni-YSZ anode-supported SOFC with a LSCF cathode. The biogas desulphurization was accomplished flowing the gas in a fixed-bed reactor, filled with activated. The fuel processing with POX has been assessed to avoid carbon deposition into the Ni-YSZ anode and convert the CH4 into H2 and CO. Short tests to check for eventual anode degradation were performed under typical operating conditions. The cell voltage was always stable under load with the tested mixtures. A cell electrical efficiency around 45% has been measured at 800°C and 80% FU. System simulations have performed as well to assess the whole system configuration under a biogas feeding. Optimization routines have been implemented to predict the best net AC efficiency achievable by a SOFC system running on biogas. Additional considerations on the management of poor LHV biogas mixture have been also assessed, showing how dry-reforming of CH4 with the CO2 already available in the biogas stream would be an excellent option needed to be investigated with further detail in the next future.


2015 ◽  
Vol 737 ◽  
pp. 635-638
Author(s):  
Ke Zhao ◽  
Zheng Kong

The general existing low temperature problem in winter of north-city sewage treatment plant in the process of waste water treatment seriously affect the efficiency of the work. The research objective of this paper is to conduct investigate in the application of AICS method in Jilin Province, a sewage treatment plant engineering example has been employed to monitor the effluent of the indicators of sewage treatment under the low temperature condition during the winter the winter low temperature under the condition of sewage treatment plant effluent of the indicators; to understand the operation situation of sewage treatment plant, and to study the efficiency of hydrolysis - AICS processing waste-water. The result shows that: hydrolysis - AICS process works well in low temperature condition, the per TN removal rate is 76.79%, average removal rate of NH3 - N is 85.76%, average TP removal rate was 93.4%, the average COD removal rate was 90.6%. The effluent meet the national level A discharge standard requirements of "urban sewage treatment plant pollutant discharge standard". And through the retrenchment of the second pond and other ancillary equipment, Hydrolysis-AICS process could efficiently reduce the costs. Besides, the advantages of Hydrolysis-AICS process also include occupying small area, and operating easily and simply. Therefore Hydrolysis-AICS process is very helpful to achieve the sewage discharging standard in the northern towns.


Sign in / Sign up

Export Citation Format

Share Document