Experimental Studies of CS Type UV Sterilizer for the Urban Sewage Treatment

2013 ◽  
Vol 361-363 ◽  
pp. 601-605
Author(s):  
Ji Ku Zhang ◽  
Yang Yang Li ◽  
Chen Zhang ◽  
Yan Bin Yang

By treating the secondary effluent of Sanbaotun sewage treatment plant in Fushun with the CS type UV Sterilizer, the experiment researches the influence on the removal rate which includes the factors of turbidity, chromaticity, initial E.coli concentration of raw water, UV dose. The results show that the turbidity does not influence on UV disinfection efficiency with the turbidity from 1.5NTU to 3.8NTU. In the low-dose UV disinfection process, the influent sewage turbidity should under 4NTU to ensure the disinfection efficiency. Low chromaticity does not affect the UV disinfection efficiency, with the influent sewage chromaticity is under 15 degrees.The initial E. coli has a certain impact on little doses of UV disinfection with the concentration from 175 × 104 A/ L to 230 × 104 A/ L, no impact on high doses of UV disinfection。

2015 ◽  
Vol 737 ◽  
pp. 635-638
Author(s):  
Ke Zhao ◽  
Zheng Kong

The general existing low temperature problem in winter of north-city sewage treatment plant in the process of waste water treatment seriously affect the efficiency of the work. The research objective of this paper is to conduct investigate in the application of AICS method in Jilin Province, a sewage treatment plant engineering example has been employed to monitor the effluent of the indicators of sewage treatment under the low temperature condition during the winter the winter low temperature under the condition of sewage treatment plant effluent of the indicators; to understand the operation situation of sewage treatment plant, and to study the efficiency of hydrolysis - AICS processing waste-water. The result shows that: hydrolysis - AICS process works well in low temperature condition, the per TN removal rate is 76.79%, average removal rate of NH3 - N is 85.76%, average TP removal rate was 93.4%, the average COD removal rate was 90.6%. The effluent meet the national level A discharge standard requirements of "urban sewage treatment plant pollutant discharge standard". And through the retrenchment of the second pond and other ancillary equipment, Hydrolysis-AICS process could efficiently reduce the costs. Besides, the advantages of Hydrolysis-AICS process also include occupying small area, and operating easily and simply. Therefore Hydrolysis-AICS process is very helpful to achieve the sewage discharging standard in the northern towns.


2020 ◽  
Vol 194 ◽  
pp. 04030
Author(s):  
Mengyin Chen ◽  
Weifeng Zeng ◽  
Guan Wang ◽  
Fangchun Lu ◽  
Jinjuan Zhang ◽  
...  

The constructed wetland project of tailwater from an urban sewage plant in central Zhejiang was selected to collect water samples in different seasons, and the samples were tested for chemical oxygen demand (COD), total phosphorus (TP), total nitrogen (TN) and other indicators. The results showed that the operation effect of the constructed wetland project is good when the effluent from the sewage treatment plant meets the Class A discharge standard. Among them, the removal effect of TP was the best, with an average removal rate of 61.52%, reaching the standards of surface water class III and class IV in some tests. Besides, the removal effect of TP was stable and varies little with seasons. The removal rates of COD and TN were relatively low and varied greatly with seasons, which were higher in spring and summer than in autumn and winter, with a negative removal rate of TN in winter. This research provides practical data for optimizing the engineering design parameters and improving the operation management to promote the operation efficiency of the constructed wetland.


2015 ◽  
Vol 10 (4) ◽  
pp. 688-694
Author(s):  
Yanjiao Gao ◽  
Runzhu Huang

In order to solve the problems of poor biodegradability and high concentrations of non-biodegradable substances from pharmaceutical wastewater after preliminary treatment, the organic components of the tail water (effluent from the preliminary treatment devises of the pharmaceutical industry wastewater treatment station) were analyzed and the method of ozonation-hydrolysis acidification was used to treat tail water from the pharmaceutical factory. The ozone dosage, the reaction time and the changes of biodegradability were studied. The results measured by GC-MS showed that there were 51 types of organic substances in tail water which reduce the biodegradability. The results of the tests showed that 30 mg/L of ozone and 60-minutes of oxidation time were suitable conditions. In the ozonation–hydrolysis acidification process the COD removal rate ranged from 20% to 50%. The test results showed that the ozonation-hydrolysis acidification method could effectively improve the biodegradability of wastewater and provide the foundation for the follow treatment in urban sewage treatment plant using biological methods.


Ecotoxicology ◽  
2016 ◽  
Vol 25 (10) ◽  
pp. 1849-1857 ◽  
Author(s):  
Dalel Belhaj ◽  
Khaled Athmouni ◽  
Bouthaina Jerbi ◽  
Monem Kallel ◽  
Habib Ayadi ◽  
...  

2013 ◽  
Vol 361-363 ◽  
pp. 595-600
Author(s):  
Ji Ku Zhang ◽  
Hui Ye Wang ◽  
Hui Ting Shao ◽  
Zhi Biao Dong

Test using CS-type UV sterilizer to do experimental study on the urban sewage , mainly research the influence of the placement time under natural light and the UV dose on photoreactivation. The results show that when disinfection ultraviolet dose is equal, bacteria photoreactivation phenomenon is more obvious with the increase of the placement time of water samples under natural light . When the placement time reaches at 3h, bacteria photoreactivation phenomenon is the most obvious. Under the same placement time, the ratio of bacteria photoreactivation decreases gradually with the increase of UV dose. When UV dose reaches at 80mJ /cm2 or the higher doses, the bacteria does not basically happen photoreactivation phenomenon. Photoreactivation phenomenon in E. coli is more obvious than that in bacteria under the same conditions.


2014 ◽  
Vol 522-524 ◽  
pp. 854-860
Author(s):  
Qing Tao Zhang ◽  
Zhi Jian Zhang ◽  
Jiong Ma ◽  
Jiao Xiang

The growth performance of duckweed (Spirodela polyrrhiza) and its removal rate of nitrate and phosphorus in sewages taken from sewage treatment plant with different processes were studied. The experiments were conducted in an environmentally controlled growth chamber. Three kinds of sewages were taken from a grit chamber, a sedimentation tank, and the anoxic pond in a sewage treatment plant, respectively. The fourth kind of sewage was mixed using the sedimentation tank sewage and the anoxic pond sewage in a volumetric ratio 1:1. The weight of duckweed biomass were determined with a balance. Wastewater samples taken from the media were analyzed for total nitrogen (TN), ammonium nitrogen (NH4N), total phosphorus (TP), phosphatephosphorus (PO4P) using AA3 Continous Flow Analyzer. The results showed that Spirodela polyrrhiza grew well in sewages taken from grit chamber and sedimentation tank of a sewage treatment plant, whereas a lot of duckweed fronds were dead in the sewage taken from the anoxic pond due to the high TP (higher than 7.9 mg/L) and TN (higher than 51.6 mg/L). The suitable TN concentration for Spirodela polyrrhiza growth should not be higher than 45 mg/L. Compared with the treatments without duckweed, the NH4N concentrations were reduced more than 60% in ST and GC sewages with duckweed due to the NH4N uptake by duckweed. Spirodela polyrrhiza could remove TN efficiently in sewages with relative low concentration TN (less than 20 mg/L), while duckweed could not remove TN effectively in sewages with high concentration TN (higher than 20 mg/L). The TN concentration in GC sewage decreased greatly in the first four days, which probably brought about anaerobic condition, thus P uptake switched to net release of P, which caused the increase of the TP concentration in the GC sewage without duckweed in the last six days. O2 or oxidant should be provided for sewage treatment system using duckweed to ensure that efficient removal of TN and TP meanwhile. The TP and PO4P concentrations in the mixed sewage with duckweed increased far more than those for no-duckweed treatments, which could be related that the dead duckweed released P into the sewage.


2013 ◽  
Vol 385-386 ◽  
pp. 857-861
Author(s):  
Xiao Ping Huang ◽  
Qi Xing Qing

On the basis of the computerized technological process control of sewage treatment in a urban sewage treatment plant in the Zone of Nanning, the author had brought forward a plan of PROFIBUS that based on automatic control system for sewage treatment, and designed the automatic control system diagram and the PROFIBUS network diagram for sewage treatment plant. At the same time, the author also made a study of techniques to control the sewage aeration, which was the most difficult problem in sewage treatment process. The fuzzy controller could indicate the changes of the water quality in treated sewage, effectively controlled the volume of aeration and then cut down the operation costs,it had produced good economic and social benefits.