Study on a Website Protection Strategy Based on Network Survivability with Effective Web Materials System

2011 ◽  
Vol 63-64 ◽  
pp. 814-817
Author(s):  
Jian Bo Liu

Through the research on the network survivability, this paper proposes a website protection strategy based on network survivability from the angle of fine management, in which the paper makes the website server to ensure uninterrupted service under attack and improve the stability of network operation. At the same time this paper proposes a framework for website protection from the perspective of data protection and file protection in order to achieve network survivability. Finally, in accordance with the proposed protection system architecture and strategy, this paper builds the network environment and emulation of illegal attacks, the experiment results show that this strategy can protect the stable operation of the website, and the survivability of website can be reflected.

1998 ◽  
Vol 38 (4-5) ◽  
pp. 29-35 ◽  
Author(s):  
C. J. Banks ◽  
P. N. Humphreys

The stability and operational performance of single stage digestion with and without liquor recycle and two stage digestion were assessed using a mixture of paper and wood as the digestion substrate. Attempts to maintain stable digestion in both single stage reactors were unsuccessful due to the inherently low natural buffering capacity exhibited; this resulted in a rapid souring of the reactor due to unbuffered volatile fatty acid (VFA) accumulation. The use of lime to control pH was unsatisfactory due to interference with the carbonate/bicarbonate equilibrium resulting in wide oscillations in the control parameter. The two stage system overcame the pH stability problems allowing stable operation for a period of 200 days without any requirement for pH control; this was attributed to the rapid flushing of VFA from the first stage reactor into the second stage, where efficient conversion to methane was established. Reactor performance was judged to be satisfactory with the breakdown of 53% of influent volatile solids. It was concluded that the reactor configuration of the two stage system offers the potential for the treatment of cellulosic wastes with a sub-optimal carbon to nitrogen ratio for conventional digestion.


Energies ◽  
2021 ◽  
Vol 14 (7) ◽  
pp. 1933
Author(s):  
Xinran Guo ◽  
Yuanchu Cheng ◽  
Jiada Wei ◽  
Yitian Luo

The dynamic characteristics of hydropower unit governing systems considerably influence the stability of hydropower units and the connected power system. The dynamic performances of hydropower units with power regulation mode (PRM) and opening regulation mode (ORM) are different. This paper establishes a detailed linear model of a hydropower unit based on the Phillips–Heffron model. The damping characteristic and stability of two regulation modes with different water inertia time constants TW were analyzed. ORM tended to provide negative damping, while PRM often provided positive damping in the major parts of the frequency range within the normal frequency oscillations when TW was large. Eigenvalue analysis illustrated that PRM has better stability than ORM. To validate the analysis, a simulation under two typical faults WAS conducted based on a nonlinear model of a hydropower unit. The simulation results illustrated that the responses of units with PRM are more stable in terms of important operating parameters, such as output power, rotor speed, and power angles. For hydropower units facing challenges in stable operation, PRM is recommended to obtain good dynamic stability.


2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Ferenc Molnar ◽  
Takashi Nishikawa ◽  
Adilson E. Motter

AbstractBehavioral homogeneity is often critical for the functioning of network systems of interacting entities. In power grids, whose stable operation requires generator frequencies to be synchronized—and thus homogeneous—across the network, previous work suggests that the stability of synchronous states can be improved by making the generators homogeneous. Here, we show that a substantial additional improvement is possible by instead making the generators suitably heterogeneous. We develop a general method for attributing this counterintuitive effect to converse symmetry breaking, a recently established phenomenon in which the system must be asymmetric to maintain a stable symmetric state. These findings constitute the first demonstration of converse symmetry breaking in real-world systems, and our method promises to enable identification of this phenomenon in other networks whose functions rely on behavioral homogeneity.


2018 ◽  
Vol 41 (8) ◽  
pp. 2352-2364 ◽  
Author(s):  
Arif Iqbal ◽  
Girish Kumar Singh

Owing to the superior properties and stable operation, the Permanent Magnet Synchronous Motor (PMSM) is preferably used in wide industrial applications. But, the stability of motor is found to be dependent on its initial operating condition, showing the chaotic characteristic. Therefore, this paper addresses the chaos control of PMSM by developing four simple but effective controllers, which are mathematically designed by using the principle of Lyapunov’s method for asymptotic global stability. A comparative performance assessment has been carried out for the developed controllers in terms of settling time and peak over shoot. Furthermore, the concept of conventional proportional-integration type controller has been extended to develop two more controllers for chaos control of PMSM. Numerical simulation has been carried out in Matlab environment for performance evaluation of developed controllers. The obtained analytical results have been validated through experimental implementation in real time environment on Multisim/Ultiboard platform.


2013 ◽  
Vol 732-733 ◽  
pp. 882-887
Author(s):  
Yong Chun Su ◽  
Hao Wei Jia

Mid-term stability assessment is an important work to support power system operation in a province power grid of China every year. The stability assessment method and process was introduced in this paper. As an example, the stability of Jiangxi province power system was evaluated in the following two years. Weak area and weak transmission line were found out in each power supply area. Prevention and control measures were proposed. According to problems among the assessment process and using the state monitoring data, an approach was discussed to increase the assessment result accuracy. The analysis conclusion provides the reference to the safe and stable operation of Jiangxi power system.


2014 ◽  
Vol 960-961 ◽  
pp. 1588-1591
Author(s):  
Xiang Dong Zhao ◽  
Xin Zhao ◽  
Ming Jun Lv ◽  
Jian Guo Liu ◽  
Feng Zhen Liu ◽  
...  

The Internet and the gradual implementation of the continuous power grid market in recent years make the power system more complex under different operating environment. Safe and stable operation of power grids have become increasingly important . With the rapidf development of the grid and constant innovation, safe and stable operation also has a new requirement , because the rapid development of the power system brings more This paper analyzes the causes of blackouts and reviews security of the power system stability problems related to measures on the security and stability of the power system operation .


2014 ◽  
Vol 521 ◽  
pp. 444-448 ◽  
Author(s):  
Yan Kai Guo ◽  
Bing Qi ◽  
Song Song Chen ◽  
Ming Zhong

The double pressures of resources and environment have brought the global power industry into the era of Smart Grid. In order to better promote the development of Demand Response of Smart Grid and to offer new regulation resources for the safe and stable operation of electric power system, OpenADR, the Open Automated Demand Response Communications Specification, has been discussed in detail, which aims at the problems of energy efficiency and the contradiction between power supply and demand. And a design scheme of Auto-DR system which introduces in detail the system architecture and the communications architecture based on OpenADR was proposed to realize the two-way communications between Utilities and end-users, and the problems such as the peak, the gap between supply and demand and the electricity structure management would be consequently solved. This scheme has a certain reference value to the Demand Side Management under the framework of Smart Grid.