An Automatic Calibration System for Multimeter Based on Fluke MET/CAL

2014 ◽  
Vol 644-650 ◽  
pp. 1303-1306
Author(s):  
Nuo Li ◽  
Guo Ding Liang ◽  
Li Yang ◽  
Yun Peng Ji ◽  
Song Yang Li

The calibration process of a digital Multi-meter (DMM) is complicated and tedious. The whole procedure needs to calibrate dozens of test points of several measuring ranges. Usually, the automatic calibration system is used to replace the manual operation. In metrology, the MAT/CAL which is a software produced by Fluke company has been widely used, but it can’t meet our special needs. This article is mainly on the introduction of design method of an automatic calibration system for DMM basing on Fluke MAT/CAL. It describes the setup of hardware, the improvement of ACC file in MAT/CAL and the basic principle of our software.

MAPAN ◽  
2021 ◽  
Author(s):  
Jintao Wang ◽  
Xiang Liu ◽  
Wencai Shi ◽  
Changhong Xu

AbstractHydrometers are widely used in industry for liquid density measurement. It is important to achieve rapid and high accuracy calibration for hydrometers. Based on the Archimedes principle, a fully automatic hydrometer calibration system in NIM was designed using Cuckow’s method. The liquid density of n-tridecane (C13H28)is calibrated with 441 g high-purity fused silica ring as the solid density standard. The buoyancy of hydrometer is measured by static weighing system with resolution 0.01 mg. The alignment between liquid surface and hydrometer scale was achieved by the lifting platform with the positioning accuracy of 10 μm. According to the weighing value of hydrometer in air and liquid, the density correction value at different scales is calculated. Hydrometer covering a full range (650–1500) kg/m3can be calibrated without changing the liquid. Taking the calibration data of PTB as reference, the experimental data show that the measurement uncertainty of this system is better than 0.3 division (k = 2).


Author(s):  
Xiong Yin ◽  
Kai Wen ◽  
Yan Wu ◽  
Lei Zhou ◽  
Jing Gong

Abstract In recent years, China ramped up imports of natural gas to satisfy the growing demand, which has increased the number of trade meters. Natural gas flowmeters need to be calibrated regularly at calibration stations to ensure their accuracy. Nowadays, the flow metrological calibration process is done by the operator manually in China, which is easy to be affected by personnel experience and proficiency. China is vigorously developing industry 4.0 and AI(artificial intelligence) technologies. In order to improve the calibration efficiency, a design scheme of intelligent controller for flow metrological calibration system is first proposed in this paper. The intelligent controller can replace the operator for process switching and flow adjustment. First, the controller selects the standard flowmeter according to the type of the calibrated flowmeter, and switches the calibration process. To accurately control the calibration flow for 180 seconds, the controller continuously adjusts the regulating valve with a sequence of commands to the actuator. These commands are generated by intelligent algorithm which is predefined in the controller. Process switching is operated automatically according to flowmeter calibration specifications. In order to reach the required flow point quickly, the flow adjustment is divided into two steps: preliminary adjustment and precise adjustment. For preliminary adjustment, a BP neural network will be built first using the field historical data and simulation results. This neural network describes the relationship between the valve-opening scheme and the calibration flow. Therefore, it could give a calibration flow as close as possible to the expected value during calibration. For precise adjustment, an adaptive PID controller is used. It could adjust the valve opening degree automatically to make sure the flow deviation meet the calibration requirements. Since the PID controller is a self-adaptive PID controller, the process of adjustment is very quick, which can reduce the calibration time largely. After each calibration, both the original neural network and the adaptive function of the controller will be updated to achieve the self-growth. With the information of the calibrated flowmeter, the entire calibration system can run automatically. The experiment in a calibration station shows that the intelligent controller can control the deviation of the flow value within 5% during 4∼5 minutes.


Author(s):  
Bo-Lin Jian ◽  
Chi-Shiuan Tsai ◽  
Ying-Che Kuo ◽  
Yu-Sying Guo

2012 ◽  
Vol 468-471 ◽  
pp. 1490-1494
Author(s):  
Qi Ren ◽  
Tian Fei Ren

ABSTRACT:It introduces a kind of an Automatic Calibration System, especially for long-term drift of oil tank gauging system. long-term drift serious influence on measuring the accuracy and reliability of the system. With theory of Hydrostatic Tank Gauging[1](HTG),as soon as the long-term drift occurring, the detection drift of oil pressure valueΔp will drift,and soon other the parameters of tank Gauging will be occurred. Because the value of Δp is difficult to directly determine, This paper puts forward a kind of automatic calibration method to obtain Δp according to the fuel level drift Δh) indirectly,By means of the HTG double level switches and fuzzy control theory. At last, by MATLAB simulation verify the correctness of the system design.


Sensors ◽  
2020 ◽  
Vol 20 (13) ◽  
pp. 3650
Author(s):  
Grzegorz Grzeczka ◽  
Maciej Klebba

This article is focused on the calibration of digital multimeters, in which the concept and practical solutions for stations with software for automatic calibration are presented. This paper also presents the general structure of the measuring system, the application scheme, and the technical implementation of measuring stations, together with the software.