The Energy Efficiency Reconstruction and Energy Consumption Assessments about a Library in Guangzhou

2011 ◽  
Vol 374-377 ◽  
pp. 672-676
Author(s):  
Liu Zhi Chen ◽  
Xiao Ning Xu ◽  
Han Wei Liu

How to reduce the energy consumption of the central air-conditioning is important for the building energy efficiency. The energy efficiency reconstruction of the central air-conditioning system on one library in Guangzhou is completed with the network control system self-developed. The operational control and operational management is integrated in the network control system. The energy consumption before and after reconstruction about the air-conditioning system of the library is detected and analyzed in the paper. The result shows the mode that operational control and operational management integrated has better energy efficiency.

2014 ◽  
Vol 628 ◽  
pp. 332-337
Author(s):  
Xiao Xia Xia ◽  
Nai Jun Zhou ◽  
Zhi Qi Wang

The energy consumption of several central air conditioning systems in summer was researched by the method of exergy analysis. Combined with actual example,the exergy loss of all the equipments and the exergy efficiency of three systems were calculated. The results show that the exergy efficiency of three systems is very low. Relatively speaking, the exergy efficiency of primary return air conditioning system with supplying air in dew point is highest. The equipment of highest exergy loss is air-conditioned room, while the exergy loss of surface air cooler is smallest. Based on this, several improvement measures were proposed to reduce exergy loss and improve exergy efficiency.


2013 ◽  
Vol 712-715 ◽  
pp. 1614-1618
Author(s):  
Jia Jia Ni ◽  
Li Tao ◽  
Yi Jun Wang ◽  
Jin Lei Wu

Through to investigation on present situation of the Changzhou Changrui Hotel air conditioning system energy consumption, by analysis the energy consumption, the power consumption of hotel central air-conditioning system charge 58% of the total electric, accounted for a large proportion. So we should take the necessary measures to reduce the expenses of air conditioning system energy consumption. According to the analysis of data on the survey, we put forward some particular energy-saving measures of central air-conditioning system of the hotel, including strengthening the building envelope insulation, energy saving technology of doors and windows, measures of roof energy saving, setting reasonable indoor temperature, adopting frequency control air-conditioning, reuse waste heat of the central air-conditioning, using the condensation water of central air conditioning to make-up water and reducing temperature of cooling tower , and drying the fresh air independently.


2020 ◽  
Vol 15 (3) ◽  
pp. 351-355
Author(s):  
Dongmei Li

Abstract In order to reduce the cost of central air conditioning, we need to reduce its energy consumption. This paper briefly introduced Internet of Things and the energy-saving and comfort monitoring system of central air conditioning based on the Internet of Things. The system took comfort degree as constraint and energy efficiency as objective to control energy saving of central air conditioning. Company X in Guanghan, Sichuan, China, was taken as an example for analysis. The system was compared with the energy-saving control system which took temperature and power as constraints. Compared with before the energy-saving control, the proportion of air conditioning downtime in the working hours of employees increased after the implementation of the two kinds of energy-saving control systems, and the proportion of downtime under the energy-saving control system designed in this study was larger; in addition, after the control of the two kinds of energy-saving systems, the energy efficiency of the air conditioning significantly improved, and the air conditioning under the control of the energy-saving system proposed in this study had more improvement in energy efficiency and higher energy-saving efficiency. The energy-saving control method proposed in this study can effectively reduce the power consumption of the central air conditioning in the office.


2011 ◽  
Vol 204-210 ◽  
pp. 327-331
Author(s):  
Jin Wang ◽  
Jing Jing Xin ◽  
You Tao Zhou ◽  
Xin Lin Li ◽  
Shu Sheng Li

Central air-conditioning energy consumption accounts for a large proportion of the buildings. And cold and heat source energy consumption accounts for about two-thirds of central air-conditioning system. For a research and development center in Shanghai, because cold and heat source capacity largely surpasses the actual demand, we propose to combine with cold sources of the two buildings. We call it "two-in-one" reconstruction. When cooling load is small, we use cold source in one building to support the two buildings. After implementation, by return on investment analysis, the average electric energy-saving rate is 9.6%. Investment can be recovered within one year.


2013 ◽  
Vol 361-363 ◽  
pp. 444-447
Author(s):  
Qian Wang ◽  
Rui Li

Air conditioning energy saving is of great significance for building energy efficiency, reduce air conditioning energy consumption can reduce most of the building energy consumption, achieve the purpose of saving energy. This article analyzed and discussed the choice of indoor design parameters, the choice of cold and heat source and the design of the transmission and distribution system.


2014 ◽  
Vol 977 ◽  
pp. 174-177
Author(s):  
Xin Li ◽  
Rui Ying Jia ◽  
Run Ping Niu

The purpose of building energy efficiency diagnosis was to find out the problems existing in the process of using energy and analysis the potential of energy saving to guide the owner who should improve the building energy efficiency as far as possible to reduce building energy consumption. This paper involves only the research on energy saving diagnosis of clean air conditioning system in pharmaceutical industry.


2014 ◽  
Vol 960-961 ◽  
pp. 639-642
Author(s):  
Xue Jing Sun

In this paper, microcontroller is applied in the central air conditioning control system. Firstly, microcontroller controller is used as controlling core to control temperature and humidity of central air conditioning control system. Secondly, PID algorithm parameters are set up for improving traditional PID control principle. Lastly, input and output values can be set and displayed by LCD screen.


2011 ◽  
Vol 374-377 ◽  
pp. 516-519
Author(s):  
Qing Chang Ren ◽  
Shang Yi Guo ◽  
Xiao Feng Lei ◽  
Wei Jia Yan

With the development of urbanization, the building energy conservation has been paid more and more attention, and 50% to 60% of the power energy consumption—the energy consumption of air-conditioning be paid attention for people. Research about measuring and analysis on energy consumption of VAV air-conditioning system is described in this paper. A measuring and analysis solution has been implemented in the VAV Air-Conditioning laboratory of Xi’an University of Architecture & Technology (XAUAT). The satisfactory results are given.