A Research on the Activated Sludge Acclimation

2012 ◽  
Vol 610-613 ◽  
pp. 1509-1512
Author(s):  
Xiao Nan Zhang ◽  
Shi Qiang Ding ◽  
Ji Run Xu

By a circular operation of anaerobic mixing - aerobic aeration – sediment drain, a sludge with low activation obtained from a common sewage treatment plant is acclimated in laboratory. The acclimation is performed with simulated sewage and composed of three periods. In the every period, the sewage concentration is successively increased, the removal percentage of COD, NH4+-N and TP are measured, when the removal is stable, the period is transformed to next one. The outside and construction characteristics of the activated sludge are observed and the protozoon is examined. Meanwhile, some influence factors such as temperature, dissolved oxygen and pH are analyzed. The experiments show that the acclimated activated sludge is able to remove the COD, NH4+-N and TP effectively under a suitable but easy-to-be obtained conditions.

1972 ◽  
Vol 7 (1) ◽  
pp. 13-20
Author(s):  
D.D.P. Cane ◽  
G.J. Farguhar

Abstract A case of filamentous activated sludge bulking was investigated at an extended aeration plant treating wastes from a highway service centre. The purpose of the study was to find an effective control measure for the bulking and, if possible, to determine the cause of the bulking condition. Experiments were conducted to determine the effects upon bulking of: (a) a controlled copper dosage to the mixed liquor, (b) variations in the organic loading rate, and (c) maintenance of high and low dissolved oxygen concentrations in the mixed liquor. The microorganism responsible for the bulking condition was tentatively identified as Sphaerotilus natans. Extensive growths of these bacteria occurred in the sludge when the mixed liquor dissolved oxygen concentration dropped below 0.5 mg/1. Such dissolved oxygen levels had frequently occurred at this plant due to the use of timed aeration cycles and the use of insufficient air supply during peak loading periods. Variations in organic loading rates were found to have no adverse effect on sludge settleability. When bulking was slight, the condition could be improved by increasing the dissolved oxygen level to 1.5 mg/1, or more. The rate at which the filamentous growths could be eliminated from a highly filamentous sludge by increased aeration was very slow, but could be greatly increased by the simultaneous feeding of copper to the mixed liquor at a dosage rate of 1.0 mg/1, based on the raw sewage flows.


PLoS ONE ◽  
2015 ◽  
Vol 10 (6) ◽  
pp. e0131532 ◽  
Author(s):  
Magna C. Paiva ◽  
Marcelo P. Ávila ◽  
Mariana P. Reis ◽  
Patrícia S. Costa ◽  
Regina M. D. Nardi ◽  
...  

2002 ◽  
Vol 46 (10) ◽  
pp. 173-179 ◽  
Author(s):  
S. Tanaka ◽  
K. Kamiyama

Effects of a thermochemical pretreatment on the anaerobic digestion of waste activated sludge (WAS) was investigated by semicontinuously-fed digesters operated at 37¡C. WAS from a return sludge line of a municipal sewage treatment plant was pretreated by autoclaving at 130°C for 5 minutes after adding 0.3g NaOH/g VSS. Solids of WAS were thermochemically solubilized to one half and then 60% or more were in totality solubilized in anaerobic digesters fed with pretreated WAS at 2-8 days of hydraulic retention times (HRT), while only 16-36% were solubilized in digesters fed with raw WAS. The adverse effect of the set temperature (130°C) on the biodegradability of protein was not found. As a result, removal rates of COD in digestion was increased from 38% to 57% at 8 days HRT by the pretreatment. A specific methane production rate in the pretreated process was three times as high as the normal process. The thermochemical pretreatment was found to be very effective to enhance biodegradability as well as solubilization of WAS in anaerobic digestion.


2004 ◽  
Vol 46 (6) ◽  
pp. 309-313 ◽  
Author(s):  
Luciana Urbano Santos ◽  
Taís Rondello Bonatti ◽  
Romeu Cantusio Neto ◽  
Regina Maura Bueno Franco

Giardia and Cryptosporidium have caused several outbreaks of gastroenteritis in humans associated with drinking water. Contaminated sewage effluents are recognized as a potential source of waterborne protozoa. Due to the lack of studies about the occurrence of these parasites in sewage samples in Brazil, we compared the efficiency of two procedures for concentrating cysts and oocysts in activated sludge samples of one sewage treatment plant. For this, the samples were submitted to i) concentration by the ether clarification procedure (ECP) and to ii) purification by sucrose flotation method (SFM) and aliquots of the pellets were examined by immunofluorescence. Giardia cysts were present in all samples (100.0%; n = 8) when using ECP and kit 1 reagents, while kit 2 resulted in six positive samples (85.7%; n = 7). As for SFM, cysts were detected in 75.0% and 100.0% of these samples (for kit 1 and 2, respectively). Regarding Cryptosporidium, two samples (25.0%; kit 1 and 28.5% for kit 2) were detected positive by using ECP, while for SFM, only one sample (examined by kit 1) was positive (12.5%). The results of the control trial revealed Giardia and Cryptosporidium recovery efficiency rates for ECP of 54.5% and 9.6%, while SFM was 10.5% and 3.2%, respectively. Considering the high concentration detected, a previous evaluation of the activated sludge before its application in agriculture is recommended and with some improvement, ECP would be an appropriate simple technique for protozoa detection in sewage samples.


2019 ◽  
Vol 11 (8) ◽  
pp. 2284 ◽  
Author(s):  
Jin Xu ◽  
Peifang Wang ◽  
Yi Li ◽  
Lihua Niu ◽  
Zhen Xing

In this study, we examined the influence of the organic carbon-to-nitrogen ratio (chemical oxygen demand (COD/N)) and dissolved oxygen (DO) levels on the removal efficiency of pollutants and on the change in total microflora in the cyclic activated sludge system (CASS) in the Nyingchi prefecture in Tibet. The results demonstrated that the treatment performance was the best when the COD/N ratio was 7:1 or the DO levels were 2–2.5 mg/L in comparison with four different tested COD/N ratios (4:1, 5:1, 7:1, and 10:1) and DO concentrations (0.5–1, 1–2, 2–2.5, and 2.5–3.5 mg/L). The treatment performance can be explained by the relative operational taxonomic unit richness and evenness of the microbial communities in activated sludge. Evident microbial variance was observed, especially different COD/N ratios and DO concentrations, which were conducive to the disposal of urban sewage in plateaus. The results help to understand sewage treatment under different COD/N ratios or DO concentrations on plateaus. This work provides practical guidance for the operation of any wastewater treatment plant on a plateau.


1988 ◽  
Vol 20 (4-5) ◽  
pp. 143-152 ◽  
Author(s):  
M. Tendaj-Xavier ◽  
J. Hultgren

Bromma sewage treatment plant is the second largest plant in Stockholm with a design flow of 160,000 m3/d. The wastewater is treated mechanically, chemically by pre-precipitation with ferrous sulphate, and biologically by the activated sludge process. The requirements for the plant are 8 mg BOD7/l, 0.4 mg P/l and 2 mg NH4+-N/l. The requirement for ammonia refers to the period July-October. In order to meet those rather stringent requirements, the biological step was expanded 3 years ago with 6 new sedimentation tanks. The 6 new tanks have the same area as the 6 old ones but they have only a depth of 3.7 m compared with the depth of the old tanks, 5.7 m. Experience from the first years of operation of the new tanks is that these tanks are more sensitive and less efficient than the older ones. It seems that the effluent suspended solids concentration from the old tanks is less influenced by rapid flow variations than the concentration in the effluent from the new secondary sedimentation tanks. During the nitrification period denitrification takes place to some degree in the secondary sedimentation tanks. This may cause loss of solids and it has been observed that the deeper old tanks usually produce an effluent of better quality and seem to be less influenced by denitrification than the new ones.


2013 ◽  
Vol 361-363 ◽  
pp. 1032-1035
Author(s):  
Xi Tian ◽  
Sheng Shu Ai ◽  
Yan Zuo ◽  
Qing Kai Ren ◽  
Zhong Yan Xie

At the sewage temperatures of 7-15°C, it used biological video microscopy and scanning electron microscopy to detect activated sludge morphology, miniature animals and flora species in northern winter sewage treatment plant. The results showed that activated sludge had dense floc with sharp edge, and was bigger at the temperatures of 13 and 15°C than at the temperatures of 7, 9 and 11°C. When the autumn and winter seasons were alternate and the sewage temperature was instability, the edge of the floc was slightly fuzzy and there was a small amount of free bacteria in activated sludge floc. The study had also shown that the temperature was higher, the type of sludge miniature animal and flora species were richer.


2012 ◽  
Vol 573-574 ◽  
pp. 1106-1111
Author(s):  
Wen Wan Meng ◽  
Lei Liao ◽  
Fei Chao Zhao ◽  
Zhen Zhou Wei

Experiments according to the current domestic situation of bio-treatment cooking fume, domesticated the activated sludge which taken from the oxidation ditch of the sewage treatment plant by using the simulated cooking fumes, discussed the concentration and morphology variation of activated sludge, researched the degradation ability of microorganism on cooking fume, the change of bacteria amount were studied in the whole process. Research showed that the sludge concentration decreased to 2878mg/L when the acclimatization time reached 50days; outlet and inlet oil concentration were consistent when the acclimatization time reached 30days while liquid fume concentration decreased to 8.436mg/L, the degradation rate of activated sludge on liquid fume was about 75% after 30 days; Microbial biomass increased first and then down become stable finally.


Sign in / Sign up

Export Citation Format

Share Document