Numerical Analysis of Fire Performance of a Spacial Pre-Stressed Steel Structure in Fire

2013 ◽  
Vol 790 ◽  
pp. 189-192
Author(s):  
Tian Hong Wang ◽  
Jin Can Xu ◽  
Hai Lun Tong ◽  
Xin Tang Wang

The numerical model of analysis of fire performance of a spatial pre-stressed steel structure with large span was established based on the software Marc. The thermal response and structural response of the pre-stressed steel structure was computed for some nodes of the structure in fire. The different fire scenes were considered for analysis of response temperature, displacements and stresses of the nodes of the pre-stressed steel structure.It is concluded that the temperature rise of the nodes of the structure is far behind that of air near the nodes, however they are quite close as the fire lasted for 3600s and almost the same after 7200s.The results show that the displacement of the node right above the inner cable is the maximum and the node above the outer cable has the smallest value of displacement and the maximum value is about two and half times as large as the minimum.The results show that the reason why the cables are out of work is that the equilibrium between the cables and the rods of the structure is lost, but not that the stress relaxation caused by thermal expansion make the cables out of work.

2011 ◽  
Vol 71-78 ◽  
pp. 3729-3732
Author(s):  
Ming Zhou ◽  
Zhi Guo Xie ◽  
Xin Tang Wang

The computational model of numerical analysis of a suspended pre-stressed steel reticulated shell subjected to fire load is established with using the software Marc. Based on the model presented here, numerical analysis of thermal response and structural response of the pre-stressed steel structure are computed. The different space height and different rise-span ratio are considered for analysis of response temperature, displacements and stresses of the pre-stressed lattice shell under fire for one fire source. It is also shown that displacement of the node right above the inner cable is the maximum among the four nodes presented here as the fire source is located at the position right below the second-ring cable of the structure. It is concluded that the influence degree of space height of the structure on the fire response of the structure is not great, but rise-span ratio has obvious and great effect on displacements and stresses of the pre-stressed steel structure with large span in fire.


2011 ◽  
Vol 71-78 ◽  
pp. 3717-3720
Author(s):  
Xin Tang Wang ◽  
Jie Yin ◽  
Ming Zhou ◽  
Zhi Guo Xie

The computational model of numerical analysis of a suspended pre-stressed steel reticulated shell subjected to fire load is established with using the software Marc. Based on the model presented here, numerical analysis of thermal response and structural response of the pre-stressed steel structure are computed for the key nodes of the structure. The different location of fire source and different space height are considered for analysis of response temperature, displacements and stresses of the pre-stressed lattice shell. It is shown that the air temperatures was much higher than the response temperatures of the nodes of the lattice shell during a quite period of time after a fire takes place, and the temperature of the cable nodes are also less than the air temperature near the nodes. It is also concluded that displacement of the node right above the inner cable is the maximum among the four nodes as the fire source is located at the position under the middle cable.


2011 ◽  
Vol 255-260 ◽  
pp. 246-250
Author(s):  
Xin Tang Wang ◽  
Zhi Guo Xie ◽  
Ming Zhou ◽  
Fen Bo Yu

The numerical model for analysis of fire behavior of the spatial pre-stressed steel structure is established based on the software Marc. Analysis of thermal response and structural response of a suspended pre-stressed steel reticulated lattice shell are computed for the key nodes of the structure. For comparison, the air temperatures near the key nodes are also calculated based on the practical formula of large space air temperature rise. The different location of fire source is considered for analysis of response temperature, displacements and stresses of the nodes of the pre-stressed lattice shell. It is shown that the air temperatures obtained from the practical formula was always higher than the response temperatures of the nodes of the lattice shell during a quite long time after a fire takes place. The results show that the displacement of the node near the center of the gymnasium in fire is close to that of the node right above the inner cable, and the displacement of the node right above the outer cable is much less than the result of the center node.


Author(s):  
Benjamin Nicoletta ◽  
John Gales ◽  
Panagiotis Kotsovinos

<p>Recent trends towards performance-based fire designs for complex and critical structures have posed questions about the fire resilience of bridge infrastructure. There are little-to-no code requirements for bridge fire resistance and practitioner guidance on the subject is limited. Research on the fire performance of cable-supported bridge structures is scarce and knowledge gaps persist that inhibit more informed fire protection designs in a variety of bridge types. There have been few numerical or experimental studies that investigate the fire performance of steel stay-cables for use in cable-supported bridges. The thermal response of these members is critical as cable systems are highly dependent on the response of individual members, such as in the case of an anchor cable for example. The study herein examines the thermal response of several varieties of unloaded steel- stay cable during exposure to a non-standard methanol pool fire and the implications for the structural response of a cable-supported bridge. Experimental thermal strain data from fire tests of various stay-cables is used to inform high-level insights for the global response of a cable-supported bridge. Namely, the effects of cable thermal expansion on the overall cable system is approximated.</p>


2020 ◽  
Vol 31 (13) ◽  
pp. 1617-1637
Author(s):  
Mohammad Naghavi Zadeh ◽  
Iman Dayyani ◽  
Mehdi Yasaee

A novel cellular mechanical metamaterial called Fish Cells that exhibits zero Poisson’s ratio in both orthogonal in-plane directions is proposed. Homogenization study on the Fish Cells tessellation is conducted and substantially zero Poisson’s ratio behavior in a homogenized tessellation is shown by numerical analysis. Experimental investigations are performed to validate the zero Poisson’s ratio feature of the metamaterial and obtain force–displacement response of the metamaterial in elastic and plastic zone. A detailed discussion about the effect of the numerical model approach and joints on the structural response of the metamaterial is presented. Morphing skin is a potential application for Fish Cells metamaterial because of the integration benefits of zero Poisson’s ratio design. The structural integrity of the Fish Cells is investigated by studying the stiffness augmentation under tension and in presence of constraints on transverse edges. Finally, geometrical enhancements for improved integrity of the Fish Cells are presented that result in substantially zero stiffness augmentation required for morphing skins.


Author(s):  
Lucas Coscia Romagnoli ◽  
Valdir Pignatta e Silva

abstract: To evaluate the behavior of semi-continuous composite beams in fire, six finite elements numerical models with several steel profiles and slab dimensions were developed in ABAQUS software. The models took into account several behaviors usually suppressed in simplified analyzes such as: geometric and materials non-linearity properties and thermal expansion effects, including indirect stresses. Three support conditions were analyzed: simply supported (axial released), axial restrained and semi-continuous, totaling 18 analyzes. The different support conditions results were compared to each other and to the fire resistance time designed by simplified methods, which followed design code recommendations.


2010 ◽  
Vol 163-167 ◽  
pp. 799-803
Author(s):  
Xin Tang Wang ◽  
Ming Zhou ◽  
Wan Zhen Wang

The computational model of numerical analysis of the planar pre-stressed steel trusses subjected to fire load is established according with main consideration to the response mechanism of the structure in fire. For the convenience of application, the EC3 constitutive model of the steel materials in fire is simplified with series expansion, and the suggested formula for each stage are unified. The fire behavior of the planar pre-stressed tubular steel trusses in which two cables are set is analyzed with the model presented here and the effect law of different factors on the bearing capacity of the structures in fire are discussed. It is concluded that fire response of the pre-stressed steel trusses is affected obviously by the different model of material under the same fire conditions, and critical temperature of the structure in fire increases with strength grade of steel material, which means that choice of the proper material model used for analysis of behavior of the steel structure under fire is very important and need to be studied further.


2012 ◽  
Vol 238 ◽  
pp. 621-624 ◽  
Author(s):  
Guang Yong Wang ◽  
Xing Qiang Wang ◽  
Guang Wei Liu

A fire performance finite element (FE) model of space grid structures in fire and after fire is proposed, and deformation, stress redistribution, failure modes of grid structures are also studied. The result shows that tensile membrane action arises when the grid is loaded after fire, and the load bearing capacity after fire is reduced by fire damage.


2014 ◽  
Vol 5 (4) ◽  
pp. 353-366 ◽  
Author(s):  
Mark Green ◽  
Kevin Hollingshead ◽  
Noureddine Bénichou

This paper considers the fire performance of concrete beams and columns that have been strengthened with fibre reinforced polymers (FRPs). Results from four recent full-scale tests are presented. A newly developed type of insulation was employed and the thickness of the insulation (15 to 20 mm) was approximately half that provided in earlier tests. All of the members survived four hours of the fire exposure. A conceptual model for design to determine when insulation is required is also presented. Further research needed to fully develop the conceptual model to a more practical design tool is outlined.


2014 ◽  
Vol 638-640 ◽  
pp. 1397-1401
Author(s):  
Kai Xiang ◽  
Guo Hui Wang ◽  
Yan Chong Pan

This paper presents a review of research progress in fire performance of concrete-filled steel tubular (CFST) columns. Experimental results of CFST columns in fire are reviewed with influence parameters, such as heights, cross-sectional dimension, section types, concrete types, concrete strengths, load ratio, load eccentricity, fire exposed sides and so on. Some conclusions of CFST columns under fire conditions are summarized. Deficiencies in the fire performance experiments of CFST columns are identified, which provide the focus for future research in the field.


Sign in / Sign up

Export Citation Format

Share Document