A Study on Optimization of Middle Vent Shaft in Subway Tunnel Ventilation System

2013 ◽  
Vol 838-841 ◽  
pp. 1381-1386
Author(s):  
Fang Lin ◽  
Yan Hua Zeng ◽  
Xiao Han Zhou ◽  
Jian Feng He

The air flow and temperature variation in the subway tunnel are different in the railway tunnel. Its necessary to study the middle vent shaft in subway tunnel ventilation system. According to the primary design documents of one subway line in Chengdu, the paper sets up the metros geometric model which is used in the SES program and also does the simulation analysis of the biggest transportation capacity in the line. The simulation mainly analyzes the adoption of the middle vent shaft which is located in the running tunnel between the station A and B. Meanwhile it also analyzes the influence of middle vent shaft on the nearby piston vent shaft, the wall surface temperature and the air temperature in the tunnel. Finally it takes temperature as the estimated index, analyzes the advantages and disadvantages of the middle vent shaft and makes the theoretic accounts for the design. The comprehensive analysis is that this middle vent shaft could be canceled.

Author(s):  
Behtash Hakimzadeh ◽  
Mohammad Reza Talaee

The creation of a safe path for evacuating passengers from a tunnel during fire accidents is an important function of a mechanical ventilation system in tunnels. In this work, the operation of emergency ventilation in the fire mode in a long railway tunnel with push–pull ventilation shafts is analyzed using a fire dynamics simulator. As the passenger trains are lengthy – and so is a tunnel – when trains pass through a tunnel, the position of fire on the train becomes an important parameter for rescuing the passengers through a safe path. The novelty of this study is in the design of emergency ventilation scenarios that consider the position of fire on the train in addition to the tunnel ventilation shafts. For this case study, a lengthy (8 km) urban railway tunnel in Tehran with four rail tracks and eight ventilation shafts is considered for designing emergency ventilation scenarios and control of fire products. The fire source is a passenger train wagon with a 25-MW heat release rate. It is shown that, during the rescue operation of the passengers, the location of fire on the train may lead to reverse the ventilation scenario compared with the traditional ones that use only the tunnel shafts. Also, it is observed that there is a region with 50 m radius around each ventilation shaft, i.e. the absolute exhaust zone, where the ventilation system must be set at the exhaust mode due to the presence of fire, to minimize the spreading of fire products downstream. All the logical scenarios of the tunnel ventilation system are designed and demonstrated to create a critical ventilation velocity in the tunnel, which would help in developing a more precise control panel of the tunnel in the fire mode.


2012 ◽  
Vol 2012 ◽  
pp. 1-12 ◽  
Author(s):  
A. G. Sheard ◽  
A. Corsini

This paper describes work aimed at establishing the ability of a tunnel ventilation fan to operate without risk of mechanical failure in the event of aerodynamic stall. The research establishes the aerodynamic characteristics of a typical tunnel ventilation fan when operated in both stable and stalled aerodynamic conditions, with and without an anti-stall stabilisation ring, with and without a “nonstalling” blade angle and at full, half, and one quarter design speed. It also measures the fan’s peak stress, thus facilitating an analysis of the implications of the experimental results for mechanical design methodology. The paper concludes by presenting three different strategies for tunnel ventilation fan selection in applications where the selected fan will most likely stall. The first strategy selects a fan with a low-blade angle that is nonstalling. The second strategy selects a fan with a high-pressure developing capability. The third strategy selects a fan with a fitted stabilisation ring. Tunnel ventilation system designers each have their favoured fan selection strategy. However, all three strategies can produce system designs within which a tunnel ventilation fan performs reliably in-service. The paper considers the advantages and disadvantages of each selection strategy and considered the strengths and weaknesses of each.


2011 ◽  
Vol 320 ◽  
pp. 382-387 ◽  
Author(s):  
Guo Min Shen ◽  
Dong Bo Li ◽  
Zhen Yang ◽  
Xiang Dong Li

To decrease the energy loss when the crane dolly climbing and smooth its move track, the arch curves of girder were studied. Geometric model of the structure was simplified reasonably according to crane bridge structure characteristic, and the finite element models of the girder with different arch curves were established. The downwarping values of the girder with different arch curves under the rated load were obtained by simulation analysis, and further the move track of the crane dolly could be drawn. Also, the advantages and disadvantages of the arch curves were discussed. Taking maximum smoothness of the move track of the crane dolly as research object, a better arch curve was obtained by shape optimization. The research can provide a basis and reference for the arch curve design of the crane girders.


2013 ◽  
Vol 319 ◽  
pp. 599-604
Author(s):  
Makhsuda Juraeva ◽  
Kyung Jin Ryu ◽  
Sang Hyun Jeong ◽  
Dong Joo Song

A computational model of existing Seoul subway tunnelwas analyzed in this research. The computational model was comprised of one natural ventilationshaft, two mechanical ventilationshafts, one mechanical airsupply, a twin-track tunnel, and a train. Understanding the flow pattern of the train-induced airflow in the tunnel was necessary to improve ventilation performance. The research objective wasto improve the air quality in the tunnel by investigating train-induced airflow in the twin-track subway tunnel numerically. The numerical analysis characterized the aerodynamic behavior and performance of the ventilation system by solving three-dimensional turbulent Reynolds-averaged Navier-Stokes equations. ANSYS CFX software was used for the computations. The ventilation and aerodynamic characteristics in the tunnel were investigated by analyzing the mass flowrateat the exits of the ventilation mechanicalshafts. As the train passed the mechanical ventilation shafts, the amount of discharged-air in the ventilationshafts decreased rapidly. The air at the exits of the ventilation shafts was gradually recovered with time, after the train passed the ventilation shafts. The developed mechanical air-supply for discharging dusty air and supplying clean airwas investigated.The computational results showed that the developed mechanical air-supplycould improve the air quality in the tunnel.


Author(s):  
Mark P. Colino ◽  
Elena B. Rosenstein

The new train signaling, traction power and tunnel ventilation system coordination guidelines enacted in National Fire Protection Association (NFPA) Standard 130 have brought the necessity and cost of tunnel ventilation fan shafts into greater focus. The guidelines were aimed at coordinating the three aforementioned rail systems to control the number of trains that could be between successive ventilation shafts during an emergency — in recognition of the fact that the best protection to both incident and non-incident train passengers and crew is to allow no more than one train in each ventilation zone. Though based in safety, these new NFPA guidelines can substantially expand the capital cost and environmental impact of new rail tunnel projects by adding more ventilation shafts and tunnel fan equipment to the scope of work. In addition, the resulting increase in the required number of ventilation shafts and tunnel fan equipment can hinder existing railroad properties as they seek to either increase their train throughput rates, or reduce their tunnel electrical infrastructure. Fortunately, a new kind of emergency ventilation shaft has been developed to facilitate compliance with the NFPA 130 Standard without the excessive capital cost and far-reaching environmental impacts of a traditional emergency ventilation shaft. This new kind of emergency ventilation shaft is called the Crossflue. The Crossflue is a horizontal passage between parallel rail tunnels with a single ventilation fan-motor unit installation. The Crossflue fan is designed to transfer air/smoke flows from one (occupied, incident) tunnel to another (unoccupied, non-incident) tunnel — thereby protecting the incident tunnel at the expense of the non-incident tunnel. The Crossflue passage has angled construction to allow a smooth transition of airflows both into and out of the adjoining tunnels. In addition to the fan, the Crossflue contains a ventilation damper, sound attenuators, ductwork transitions and flexible connectors within the fan equipment line-up; the functionality of all this mechanical equipment is described in the paper. To preserve underground space and minimize the rock excavation, the Crossflue fan is both remotely-powered and remotely-controlled; the fan is only operated as part of a pre-programmed response to tunnel fire events. The methodology utilized to design the Crossflue was taken from the Subway Environmental Design Handbook (SEDH); the SEDH [1] was specifically developed for rail tunnel ventilation design and is the preeminent reference volume in the industry. In summary, the Crossflue provides a dual benefit of achieving NFPA 130 compliance, while at the same time minimizing the construction, equipment, environmental, and energy costs of a traditional tunnel ventilation shaft.


2014 ◽  
Vol 635-637 ◽  
pp. 532-536
Author(s):  
Pei Shu ◽  
Hong Xin Zhang ◽  
Ru Qin Xiao ◽  
Jin Zhu Shi

For the bush-burning problem in the course of the engine operation. Taking a certain kind of engine as reference, build a 3D geometric model of the engine-oil flow field in the ideal stable conditions with GAMBIT and conduct a simulation of it with FLUENT. It reveals that we can have an intuitive understanding of the flow state and pressure distribution of the engine-oil inside the clearance between the crankshaft main journal and crankshaft bearing as well as the rod journal and rod bearing which provides basis for a further refining of bearing lubrication system, improving the lubrication method and enhancing the efficiency of the lubrication.


Sign in / Sign up

Export Citation Format

Share Document