Plastic Analysis on Buckling Restrained Braced Steel Frame

2013 ◽  
Vol 859 ◽  
pp. 157-162
Author(s):  
Xue Zou ◽  
Jun Zhao ◽  
En He Bao ◽  
Yi Hu Chen

Six pieces of building models were designed for studying the multilayer buckling restrained braced steel frame in this paper. The main parameter in the study included the frame strength and the level Participation ratio β. Second-order nonlinear time history analyses for models are conducted based on plastic hinge theory. The parametric analysis was performed on story displacement and shear. The results revealed that story bending deformation become more remarkable when the frame strength is increasing from 0.3 to 0.5 or the level Participation ratio β from 30% to 90%, and this situation is more obvious on the upper layer. The share of shear by the buckling restrained brace and the largest story shear ratio get larger in these models as the frame strength and the level Participation ratio β increasing.

Author(s):  
Rafaa M. Abbas ◽  
Ahmed Sada Dheeb

This study concerns with the investigation of the second-order geometric nonlinearity effects of P-Delta analysis on the dynamic response of high rise steel buildings due to deterministic wind load. Linear and nonlinear time history analyses were conducted to analyze different tall steel building models adopted in the study. Five steel building models ranging from 10 to 50 stories were numerically modeled and analyzed using finite element code ETABS (version 16.0.3). Deterministic dynamic wind load per ASCE 7-10 is applied to the buildings as a main lateral load. Comparative study between linear and nonlinear time history analyses reveals that nonlinear time history analysis including P-Delta effects displayed larger values of buildings lateral sway than those of linear time history analysis. Generally, including P-Delta effect in the nonlinear analysis increases the flexibility of the building structure, and thus increases response peak values and that peak values occur at a longer time periods indicating lesser response oscillations. The study recommends that P-Delta effect need to be addressed by any dynamic wind analysis for tall steel buildings with 20 story height or more.


Actuators ◽  
2021 ◽  
Vol 10 (4) ◽  
pp. 73
Author(s):  
Osman Hansu ◽  
Esra Mete Güneyisi

This study addresses an alternative use of viscous dampers (VDs) associated with buckling restrained braces (BRBs) as innovative seismic protection devices. For this purpose, 4-, 8- and 12-story steel bare frames were designed with 6.5 m equal span length and 4 m story height. Thereafter, they were seismically improved by mounting the VDs and BRBs in three patterns, namely outer bays, inner bays, and all bays over the frame heights. The structures were modeled using SAP 2000 software and evaluated by the nonlinear time history analyses subjected to the six natural ground motions. The seismic responses of the structures were investigated for the lateral displacement, interstory drift, absolute acceleration, maximum base shear, and time history of roof displacement. The results clearly indicated that the VDs and BRBs reduced seismic demands significantly compared to the bare frame. Moreover, the all-bay pattern performed better than the others.


2021 ◽  
Vol 13 (8) ◽  
pp. 4278
Author(s):  
Svetlana Tam ◽  
Jenna Wong

Sustainability addresses the need to reduce the structure’s impact on the environment but does not reduce the environment’s impact on the structure. To explore this relationship, this study focuses on quantifying the impact of green roofs or vegetated roofs on seismic responses such as story displacements, interstory drifts, and floor level accelerations. Using an archetype three-story steel moment frame, nonlinear time history analyses are conducted in OpenSees for a shallow and deep green roof using a suite of ground motions from various distances from the fault to identify key trends and sensitivities in response.


2018 ◽  
Vol 20 (1) ◽  
pp. 35
Author(s):  
Pamuda Pudjisuryadi ◽  
Benjamin Lumantarna ◽  
Ryan Setiawan ◽  
Christian Handoko

The recent seismic code SNI 1726-2012 is significantly different compared to the older code SNI 1726-2002. The seismic hazard map was significantly changed and the level of maximum considered earthquake was significantly increased. Therefore, buildings designed according to outdated code may not resist the higher demand required by newer code. In this study, seismic performance of Hotel X in Kupang, Indonesia which was designed based on SNI-1726-2002 is investigated. The structure was analyzed using Nonlinear Time History Analysis. The seismic load used was a spectrum consistent ground acceleration generated from El-Centro 18 May 1940 North-South component in accordance to SNI 1726-2012. The results show that Hotel X can resist maximum considered earthquake required by SNI 1726-2012. The maximum drift ratio is 0.81% which is lower than the limit set by FEMA 356-2000 (2%). Plastic hinge damage level is also lower than the allowance in ACMC 2001.


2020 ◽  
Vol 2020 ◽  
pp. 1-17
Author(s):  
Vui Van Cao ◽  
Son Quang Pham

The literature related to earthquakes and fibre reinforced polymer (FRP) retrofitting can be divided into two main categories: (1) the applications of FRP to retrofit structures subjected to single traditional earthquakes and (2) the effects of mainshock-aftershock sequences on original structures (without FRP retrofitting). Research on using FRP to mitigate the risk of pulse-type mainshock-aftershock sequences for reinforced concrete (RC) structures located in near-fault regions is hardly found in the literature and is thus the aim of this study. To achieve this aim, a four-storey RC frame, near-fault mainshocks, and seismic sequences were selected. The frame was retrofitted using FRP wraps at plastic hinge locations. Nonlinear time history and damage analyses of the original and FRP-retrofitted frames subjected to these near-fault mainshocks and seismic sequences were conducted. The results showed that aftershocks significantly increase the damage indices of the frames, shifting the damage state of the original frame from severe damage to collapse and the damage state of the FRP-retrofitted frame from light damage to moderate damage. FRP retrofitting successfully reduced the risk of seismic sequences by reducing the damage two levels, shifting the damage state of the original frame from collapse to moderate damage.


2011 ◽  
Vol 255-260 ◽  
pp. 2330-2334 ◽  
Author(s):  
Yu Zhang ◽  
Quan Wang Li ◽  
Jian Sheng Fan

The earthquake may attack the structural building from any angle, but in current seismic design codes, this type of uncertainty is seldom accounted. The uncertainty associated with the direction of earthquake excitation was considered in this paper, and its effect on structural responses was investigated. For this purpose, a simple 3-dimensional model with symmetric plan was established, which had fundamental periods ranged from 0.1s to 5.0s, and was subjected to a set of 30 ground motion pairs for which both linear and nonlinear time history analyses were performed. Analyzing results showed that, on average, the elastic roof acceleration is 32% underestimated, and the inelastic roof displacement is 18% underestimated if the variation of earthquake excitation direction is not consider. Recognizing this, a modification factor for the seismic demand was proposed thorough a statistical analysis, which guarantees a probability of 95% design safety


Sign in / Sign up

Export Citation Format

Share Document