Glucosamine Coating for Inhibiting Bacterial Adhesion to Titanium Surfaces

2005 ◽  
Vol 288-289 ◽  
pp. 343-346 ◽  
Author(s):  
Yuehuei H. An ◽  
Melissa Farino ◽  
Qian K. Kang ◽  
Marina V. Demcheva ◽  
John Vournakis

It is known that glucosamine/chitosan derivatives have the ability of inhibiting bacterial adhesion to tooth and biomaterial surfaces. The hypotheses of this article included 1) the inhibition effects of different (chemically) glucosamine products are different and 2) more water-soluble glucosamine preparation(s) may have a superior inhibition effect. The basic testing systems are in vitro static adhesion models and the amount of the adhesion is evaluated by direct counting using epifluorecense microscopy. The test material is a smooth surfaced commercially pure titanium (cp-Ti). The bacterium tested is Staphylococcus aureus. The results showed that compared to the control samples (without glucosamine or chitosan coating) the sulfated p-GlcNAc and Sigma glucosamine HCl significantly inhibited S. aureus adhesion to titanium surfaces (94% and 78% respectively)

2019 ◽  
Vol 7 (4) ◽  
pp. 109 ◽  
Author(s):  
Tetsuhiro Tsujino ◽  
Akira Takahashi ◽  
Taisuke Watanabe ◽  
Kazushige Isobe ◽  
Yutaka Kitamura ◽  
...  

Recent progress in the industrial development of dental implants has improved their surface bio-affinity, while clinical implantologists attempt to improve it through coating with various compounds, including platelet-rich plasma (PRP) in clinical settings. However, it is poorly understood how PRP acts on titanium surfaces. To validate this surface modification method and demonstrate how platelet-derived soluble biomolecules released from the activated adherent platelets act on plain, commercially pure-titanium (cp-Ti) plates, we evaluated the distribution of biomolecules by immunofluorescence. PPARγ, PDGF-B, and TGFβ1 were similarly released at immunofluorescence levels from activated adherent platelets, retained in the surrounding extra-platelet spaces for a while, and did not immediately diffuse away to distant spaces. Exogenously added CaCl2 augmented release and retention of those biomolecules along with activation and aggregation. Taken together with our previous data regarding platelet adhesion, these findings suggest that especially when treated with CaCl2, platelets immediately adhere on cp-Ti plates to release their stored biomolecules in the absence of plasma proteins and that these biomolecules do not diffuse away, but stay longer in extra-platelet spaces around the platelets by newly formed, immature fibrin fiber fragments. Consequently, these retained biomolecules are anticipated to cooperatively stabilize implants by stimulating alveolar bone regeneration and integration.


2012 ◽  
Vol 548 ◽  
pp. 174-178 ◽  
Author(s):  
Chong Yang Gao ◽  
Wei Ran Lu

By using a dislocation-based plastic constitutive model for hcp metals developed by us recently, the dynamic thermomechanical response of an important industrial material, commercially pure titanium (CP-Ti), was described at different temperatures and strain rates. The constitutive parameters of the material are determined by an efficient optimization method for a globally optimal solution. The model can well predict the dynamic response of CP-Ti by the comparison with experimental data and the Nemat-Nasser-Guo model.


Author(s):  
Karibeeran Shanmuga Sundaram ◽  
Gurusami Kiliyappan ◽  
Senthil Kumaran Selvadurai

Laser shock peening (LSP) is one of the innovative technique that produces a compressive residual stress on the surface of metallic materials, thereby significantly increasing its fatigue life in applications where failure is caused by surface-initiated cracks. The specimens were treated with laser shock waves with different processing parameters, and characterization studies were made on treated specimens. The purpose of the present study was to investigate the influence of Nd:YAG laser on commercially pure titanium (CP-Ti) used in prosthetic dental restorations. The treatment influenced change in microstructure, micro hardness, surface roughness, and wear resistance characteristics. Though CP-Ti is considered as an excellent material for dental applications due to its outstanding biocompatibility, it is not suitable when high mastication forces are applied. In the present study, pulsed Nd:YAG laser surface treatment technique was adopted to improve the wear resistance of CP-Ti. The wear test pin specimens of CP-Ti were investment cast with centrifugal titanium casting machine. The wear properties of specimens were evaluated after LSP on a “pin-on-disc” wear testing tribometer, as per ASTM G99-05 standards. The results of the wear experiment showed that the treated laser surface has higher wear resistance, micro hardness, and surface roughness compared to as-cast samples. The improvement of wear resistance may be attributed due to grain refinement imparted by LSP processes. The microstructure, wear surfaces, wear debris, and morphology of the specimen were analyzed by using optical electron microscope, scanning electron microscope, and X-ray diffraction (XRD). The data were compared using ANOVA and post-hoc Tukey tests. The characteristic change resulted in increase in wear resistance and decrease in wear rate. Hence, it is evident that the more reliable and removable partial denture metal frameworks for dental prostheses may find its applications.


2005 ◽  
Vol 19 (2) ◽  
pp. 139-143 ◽  
Author(s):  
Wagner Sotero Fragoso ◽  
Guilherme Elias Pessanha Henriques ◽  
Edwin Fernando Ruiz Contreras ◽  
Marcelo Ferraz Mesquita

Commercially pure titanium (CP Ti) has been widely applied to fabricate cast devices because of its favorable properties. However, the mold temperature recommended for the manufacture of casts has been considered relatively low, causing inadequate castability and poor marginal fit of cast crowns. This study evaluated and compared the influence of mold temperature (430°C - as control, 550°C, 670°C) on the marginal discrepancies of cast CP Ti crowns. Eight bovine teeth were prepared on a mechanical grinding device and impressions were used to duplicate each tooth and produce eight master dies. Twenty-four crowns were fabricated using CP Ti in three different groups of mold temperature (n = 8): 430°C (as control), 550°C and 670°C. The gap between the crown and the bovine tooth was measured at 50 X magnification with a traveling microscope. The marginal fit values of the cast CP Ti crowns were submitted to the Kruskal-Wallis test (p = 0.03). The 550°C group (95.0 µm) showed significantly better marginal fit than the crowns of the 430°C group (203.4 µm) and 670°C group (213.8 µm). Better marginal fit for cast CP Ti crowns was observed with the mold temperature of 550°C, differing from the 430°C recommended by the manufacturer.


2014 ◽  
Vol 28 (12) ◽  
pp. 1207-1218 ◽  
Author(s):  
Miguel A. Fernández-Rodríguez ◽  
Alda Y. Sánchez-Treviño ◽  
Elvira De Luna-Bertos ◽  
Javier Ramos-Torrecillas ◽  
Olga García-Martínez ◽  
...  

2010 ◽  
Vol 654-656 ◽  
pp. 2172-2175
Author(s):  
Kyosuke Ueda ◽  
Hajime Suto ◽  
Kaori Nakaie ◽  
Takayuki Narushima

The surface modification of commercially pure titanium (CP Ti) by pack cementation treatment at 973 K using tetracalcium phosphate (Ca4(PO4)2O, TTCP) slurry was investigated. An HAp phase and a CaTiO3 phase were observed on the reaction layer of the CP Ti substrate after pack cementation treatment at 973 K for 86.4 ks. TTCP powder decomposed to HAp and CaO, and CaO reacted with TiO2 to form CaTiO3. The reaction layer on the CP Ti substrate consisted of inner and outer layers and the particles were in the outer reaction layer. The pores observed on the reaction layer were formed by the detachment of particles from the outer layer. The bonding strength of the reaction layer was 68.1 MPa. Apatite completely covered the surface of the pack-cementation-treated CP Ti after immersion in Kokubo solution for 21.6 ks; such rapid apatite formation suggests that pack cementation treatment improves the biocompatibility of titanium.


2018 ◽  
Vol 53 (9) ◽  
pp. 6872-6892 ◽  
Author(s):  
S. Khayatzadeh ◽  
M. J. Thomas ◽  
Y. Millet ◽  
S. Rahimi

Author(s):  
Gry Hulsart-Billström ◽  
Oscar Janson ◽  
Håkan Engqvist ◽  
Ken Welch ◽  
Jaan Hong

Abstract The release of growth factors from platelets, mediated by the coagulation and the complement system, plays an important role in the bone formation around implants. This study aimed at exploring the thromboinflammatory response of H2O2-alkali soaked commercially pure titanium grade 2 discs exposed to whole human blood, as a way to assess the bioactivity of the discs. Commercially pure titanium grade 2 discs were modified by soaking in H2O2, NaOH and Ca(OH)2. The platelet aggregation, coagulation activation and complement activation was assessed by exposing the discs to fresh whole blood from human donors. The platelet aggregation was examined by a cell counter and the coagulation and complement activation were assessed by ELISA-measurements of the concentration of thrombin-antithrombin complex, C3a and terminal complement complex. The modified surface showed a statistically significant increased platelet aggregation, coagulation activation and complement activation compared to unexposed blood. The surface also showed a statistically significant increase of coagulation activation compared to PVC. The results of this study showed that the H2O2-alkali soaked surfaces induced a thromboinflammatory response that indicates that the surfaces are bioactive.