scholarly journals Microstructure of a Paint Primer - a Data-Constrained Modeling Analysis

2010 ◽  
Vol 654-656 ◽  
pp. 1686-1689 ◽  
Author(s):  
Sam Yang ◽  
Da Chao Gao ◽  
Tim Muster ◽  
Andrew Tulloh ◽  
Scott Furman ◽  
...  

Metallic aerospace components are commonly painted with a primer to improve their corrosion resistance. The primer contains a polymer matrix with embedded corrosion inhibitor and filler particles. Its performance is determined by the microscopic distributions of the particles. Various techniques have been used to quantify such distributions, including X-ray micro-computed tomography (CT). However, its success is sometimes limited by factors such as different particles having similar X-ray CT absorption properties and their size being smaller than the resolution of micro-CT. In this paper, we have performed two X-ray CT measurements on a paint primer sample consisting of SrCrO4 corrosion inhibitor particles and UV-absorbing TiO2 filler particles. Fe and Ti targets were used as X-ray sources with different spectral distributions. The measured CT data sets were used as constraints for a data-constrained microstructure modeling (DCM) prediction of the sample’s microscopic structures. DCM model predictions were compared with experimental elemental surface maps and showed reasonable degree of agreement, suggesting X-ray micro-CT combined with DCM modeling would be a powerful technique for detailing the dynamics of chromate-inhibited primers and other multiphase systems where the components are sensitive to incident X-ray energy.

Materials ◽  
2021 ◽  
Vol 14 (8) ◽  
pp. 1995
Author(s):  
Mirko Sinico ◽  
Suraj Dinkar Jadhav ◽  
Ann Witvrouw ◽  
Kim Vanmeensel ◽  
Wim Dewulf

Recently, the use of novel CuCr1 surface-modified powder for reliable laser powder-bed fusion (LPBF) manufacturing has been proposed, enabling a broader LPBF processing window and longer powder storage life. Nevertheless, virgin CuCr1 powder is also LPBF processable, on the condition that a high-energy density is employed. In this work, we compare two dense specimens produced from virgin and surface-modified CuCr1 powder. Furthermore, a third sample fabricated from surface-modified powder is characterized to understand an abnormal porosity content initially detected through Archimedes testing. Utilizing high-resolution micro-CT scans, the nature of the defects present in the different samples is revealed. Pores are analyzed in terms of size, morphology and spatial distribution. The micro-CT data reveal that the virgin CuCr1 dense specimen displays keyhole pores plus pit cavities spanning multiple layer thicknesses. On the other hand, the sample fabricated with the surface-modified CuCr1 powder mainly contains small and spherical equi-distributed metallurgical defects. Finally, the CT analysis of the third specimen reveals the presence of a W contamination, favoring lack-of-fusion pores between subsequent LPBF layers. The LPBF melting mode (keyhole or conductive), the properties of the material, and the potential presence of contaminants are connected to the different porosity types and discussed.


2018 ◽  
Vol 314 (3) ◽  
pp. F493-F499 ◽  
Author(s):  
Ruslan Hlushchuk ◽  
Cédric Zubler ◽  
Sébastien Barré ◽  
Carlos Correa Shokiche ◽  
Laura Schaad ◽  
...  

In the last decades, the contrast-enhanced micro-computed tomography (micro-CT) imaging of a whole animal kidney became increasingly important. The visualization was mainly limited to middle-sized vessels. Since modern desktop micro-CT scanners provide the necessary detail resolution, we developed an approach for rapid visualization and consistent assessment of kidney vasculature and glomeruli number. This method is based on μAngiofil, a new polymerizing contrast agent with homogenous X-ray absorption, which provides continuous filling of the complete vasculature and enables correlative imaging approaches. For rapid and reliable kidney morphometry, the microangio-CT (µaCT) data sets from glial cell line-derived neurotrophic factor (GDNF)+/− mice and their wild-type littermates were used. The results were obtained much faster compared with the current gold standard, histology-based stereology, and without processing artifacts. The histology-based morphometry was done afterward on the same kidneys. Both approaches revealed that the GDNF+/− male mice had about 40% fewer glomeruli. Furthermore, our approach allows for the definition of sites of interest for further histological investigation, i.e., correlative morphology. The polymerized μAngiofil stays in perfused vessels and is autofluorescent, which is what greatly facilitates the matching of histological sections with µaCT data. The presented approach is a time-efficient, reliable, qualitative, and quantitative methodology. Besides glomerular morphometry, the µaCT data can be used for qualitative and quantitative analysis of the kidney vasculature and correlative morphology.


2017 ◽  
Vol 2017 ◽  
pp. 1-6 ◽  
Author(s):  
Yuhui Chen ◽  
He Cao ◽  
Dawei Sun ◽  
Changxin Lin ◽  
Liang Wang ◽  
...  

Bone fracture is a global healthcare issue for high rates of delayed healing and nonunions. Although n-3 polyunsaturated fatty acid (PUFA) is considered as a beneficial factor for bone metabolism, only few studies till date focused on the effects of n-3 PUFAs on fracture healing. In this study, we investigated the effect of endogenous n-3 PUFAs on fracture healing by measuring femur fracture repair in bothfat-1transgenic mice and WT mice. Proximal femoral fracture model was established infat-1transgenic mice and WT mice, respectively, and then the fracture was analyzed by using X-ray, micro-computed tomography (micro-CT), and histological assessment at 7, 14, 21, 28, and 35 days after fixation. The results showed that compared with WT mice,fat-1mice exhibited acceleration in fracture healing through radiographic and histological analysis (18–21 days versus 21–28 days postfracture). Meanwhile, X-ray and micro-CT analysis that showed better remodeling callus formation were in thefat-1group compared to WT group. Furthermore, histological analysis revealed that endogenous n-3 PUFAs promoted local endochondral ossification and accelerated the remodeling of calcified calluses after fracture. In conclusion, the present study indicated that endogenously produced n-3 PUFAs promote fracture healing process and accelerate bone remodeling in mice, and supplementation of n-3 PUFAs was positively associated with fracture healing.


2019 ◽  
Vol 34 (2) ◽  
pp. 97-102
Author(s):  
M. A. Rodriguez ◽  
T. T. Amon ◽  
J. J. M. Griego ◽  
H. Brown-Shaklee ◽  
N. Green

Advancements in computer technology have enabled three-dimensional (3D) reconstruction, data-stitching, and manipulation of 3D data obtained on X-ray imaging systems such as micro-computed tomography (μ-CT). Likewise, intuitive evaluation of these 3D datasets can be enhanced by recent advances in virtual reality (VR) hardware and software. Additionally, the generation, viewing, and manipulation of 3D X-ray diffraction datasets, such as pole figures employed for texture analysis, can also benefit from these advanced visualization techniques. We present newly-developed protocols for porting 3D data (as TIFF-stacks) into a Unity gaming software platform so that data may be toured, manipulated, and evaluated within a more-intuitive VR environment through the use of game-like controls and 3D headsets. We demonstrate this capability by rendering μ-CT data of a polymer dogbone test bar at various stages of in situ mechanical strain. An additional experiment is presented showing 3D XRD data collected on an aluminum test block with vias. These 3D XRD data for texture analysis (χ, ϕ, 2θ dimensions) enables the viewer to visually inspect 3D pole figures and detect the presence or absence of in-plane residual macrostrain. These two examples serve to illustrate the benefits of this new methodology for multidimensional analysis.


2020 ◽  
Author(s):  
Carlo Porfido ◽  
Roberto Rizzo ◽  
David Healy ◽  
Matteo Spagnuolo ◽  
Roberto Terzano ◽  
...  

<div><div><div><p>This work presents a study on the fracturing behaviour of a quartz tempered clay-based ceramic subjected to damage in freeze-thaw cycles. X-ray micro-computed tomography (micro-CT) provided high-resolution imaging of the ceramic before and during the freeze-thaw treatment, allowing to analyse a fully water-saturated sample using a special thermal stage designed to keep the sample frozen during analyses. Micro-CT 3D renderings showed the internal features of the specimen (i.e., quartz grain distribution), the increment of fracture count and size, and the detachment of ceramic and/or temper fragments from the edges of the sample over the cycles. Selected 2D micrographs, before and after freeze-thawing treatment, were analysed using the MATLAB toolbox FracPaQ. This software provided detailed data on fracture length, intensity, density, orientation and connectivity, and enabled to interpret the process of fracture initiation and propagation inside the material. These results showed that the temper plays a crucial role in ceramic fracturing behaviour under freeze- thawing conditions, as damage propagation is influenced by quartz grain distribution and orientation within the material. The study described in this work, not only offers new insights into the fracture dynamics of freeze-thawed clay-based ceramics, but also presents a new methodological approach to quantitatively measure fracture damage in porous materials.</p></div></div></div>


2020 ◽  
Vol 47 (3) ◽  
pp. 337-343
Author(s):  
Dongyun Lee ◽  
Jisun Shin

Molar-incisor malformation (MIM) is a new type of root anomaly reported recently. The characteristics of MIM are dysplastic root formations, constriction of pulp chambers and presence of calcified matrices at the level of cementoenamel junction in permanent first molars and primary second molars. In some cases, permanent maxillary incisors are also affected.The permanent first molars of the patient in this case report were affected with MIM. Generalized pulp stones were observed in overall primary dentition. Micro-computed tomography (micro-CT) imaging and scanning electron microscope-energy dispersive X-ray spectrometer analysis were performed on the extracted mandibular first molar and maxillary primary second molar of the patient. Micro-CT images revealed the discontinuity of enamel directly connected to an accessory canal of the root.


2021 ◽  
Vol 1135 (1) ◽  
pp. 012023
Author(s):  
Rickard Olsson ◽  
John Powell ◽  
Jan Frostevarg ◽  
Alexander F.H. Kaplan

Abstract Surfaces generated by Additive Manufacturing or laser texturing can involve the solidification of droplets of liquid, which can give rise to overhanging features on the solidified surface. Overhanging features add a layer of complexity to the surface topography and are undetectable by standard surface roughness measurement techniques such as profilometry. Such features are important because they can have a considerable effect on surface properties such as wettability. New techniques and algorithms are therefore required to analyse and quantify convoluted surfaces with overhanging (re-entrant) features. Earlier work by the authors introduced the concept of using X-ray micro-computed tomography (Micro-CT) to identify the directions of vectors normal to the surface at any point and thus indicate the presence or absence of overhanging features. This paper divides overhanging features into two types; simple and compound, and introduces new, size independent, analysis techniques which measure what proportion of each type is on the surface. Another extension of the analysis is the comparison of surface profiles taken in different directions in order to identify any surface roughness anisotropies.


Materials ◽  
2020 ◽  
Vol 13 (16) ◽  
pp. 3606
Author(s):  
Armin Rashidi ◽  
Tina Olfatbakhsh ◽  
Bryn Crawford ◽  
Abbas S. Milani

X-ray computed tomography provides qualitative and quantitative structural and compositional information for a broad range of materials. Yet, its contribution to the field of advanced composites such as carbon fiber reinforced polymers is still limited by factors such as low imaging contrast, due to scarce X-ray attenuation features. This article, through a review of the state of the art, followed by an example case study on Micro-computed tomography (CT) analysis of low X-ray absorptive dry and prepreg carbon woven fabric composites, aims to highlight and address some challenges as well as best practices on performing scans that can capture key features of the material. In the case study, utilizing an Xradia Micro-CT-400, important aspects such as obtaining sufficient contrast, an examination of thin samples, sample size/resolution issues, and image-based modeling are discussed. The outcome of an optimized workflow in Micro-CT of composite fabrics can assist in further research efforts such as the generation of surface or volume meshes for the numerical modeling of underlying deformation mechanisms during their manufacturing processes.


2020 ◽  
Vol 94 (3) ◽  
pp. 417-435 ◽  
Author(s):  
Sarah Kachovich ◽  
Jonathan C. Aitchison

AbstractA new, previously undescribed Middle Ordovician (middle Darriwilian: Dw2) radiolarian assemblage has been recovered from the Table Cove Formation at Piccadilly Quarry, western Newfoundland. Constituents of the fauna described herein are both distinctive and exceptionally well preserved. Three-dimensional X-ray micro-computed tomography (μ-CT) is used to make a detailed examination of four key spumellarian specimens. This technology enables visualization of hitherto ambiguous details of the internal morphologies of key lower Paleozoic taxonomic groups, among which a lack of knowledge has impeded resolution of higher taxonomic rankings.


Sign in / Sign up

Export Citation Format

Share Document