Comparison of PT and aPTT values drawn by venipuncture and arterial line using three discard volumes

1992 ◽  
Vol 1 (3) ◽  
pp. 94-101 ◽  
Author(s):  
E Konopad ◽  
M Grace ◽  
R Johnston ◽  
T Noseworthy ◽  
A Shustack

BACKGROUND: Blood samples obtained through heparinized arterial catheters are used routinely for a variety of laboratory tests. Accuracy of coagulation studies performed from samples obtained in this fashion continues to be questioned, particularly in regard to the minimum discard volume necessary to clear the catheter of heparinized solution. OBJECTIVE: To examine differences between prothrombin time and activated partial thromboplastin time values obtained from blood drawn by venipuncture and from an indwelling intra-arterial line using three discard volumes. METHODS: Prothrombin time and activated partial thromboplastin time samples were drawn by venipuncture from 41 critically ill adult patients. Simultaneously, three consecutive blood samples of 2.3 mL were drawn from the arterial line after an initial discard volume of 3 mL (discard volumes of 3.0, 5.3 and 7.6 mL). RESULTS: Significant differences were found between arterial and venous prothrombin time values for the 3-mL discard volume group, as well as between arterial and venous activated partial thromboplastin time values for all three discard volume groups (paired t-test, Bonferroni correction). CONCLUSION: We recommend that when drawing prothrombin time and activated partial thromboplastin time samples from an arterial line, a 5.3-mL discard volume be used.

1993 ◽  
Vol 2 (1) ◽  
pp. 88-95 ◽  
Author(s):  
K Templin ◽  
M Shively ◽  
J Riley

OBJECTIVE: To determine the accuracy of activated partial thromboplastin time and prothrombin time studies when samples are drawn through heparinized arterial lines. METHODS: A total sample of 90 grouped blood samples (from 30 subjects) was used. Patients were all male, with a mean age of 65 and were studied within 24 hours of percutaneous transluminal coronary angioplasty. Each patient had three venous control and arterial line sample sets (a total of 90 blood samples) drawn when routinely ordered for monitoring therapy. For the arterial line sample, a discard volume of the deadspace, deadspace + 2 mL, or deadspace + 4 mL was randomly assigned for each sample. The venous control volumes were the same for all three sample sets. RESULTS: A 2 x 3 repeated measures analysis of variance was used to analyze the results. The independent variables were the source of the sample (venous vs arterial) and the discard volume of arterial blood (deadspace, deadspace + 2 mL, deadspace + 4 mL). The dependent variables were the activated partial thromboplastin time and prothrombin time values. Mean arterial activated partial thromboplastin time values were significantly higher than the corresponding venous values. Mean activated partial thromboplastin time values were not significantly different among the discard volumes of blood drawn. However, there was a significant source by volume interaction. Tukey post-hoc comparisons of venous-arterial activated partial thromboplastin time differences among the three volumes showed significant differences between deadspace volume and deadspace + 2 mL, and deadspace volume and deadspace + 4 mL. There was no significant difference between deadspace + 2 mL and deadspace + 4 mL volumes. CONCLUSION: Results indicated that the minimal amount of discard volume for accurate activated partial thromboplastin time values in this population of percutaneous transluminal coronary angioplasty patients was the catheter deadspace volume plus 2 mL (total 3.6 mL).


2007 ◽  
Vol 131 (2) ◽  
pp. 293-296
Author(s):  
Alexander Kratz ◽  
Raneem O. Salem ◽  
Elizabeth M. Van Cott

Abstract Context.—Technologic advances affecting analyzers used in clinical laboratories have changed the methods used to obtain many laboratory measurements, and many novel parameters are now available. The effects of specimen transport through a pneumatic tube system on laboratory results obtained with such modern instruments are unclear. Objective.—To determine the effects of sample transport through a pneumatic tube system on routine and novel hematology and coagulation parameters obtained on state-of-the-art analyzers. Design.—Paired blood samples from 33 healthy volunteers were either hand delivered to the clinical laboratory or transported through a pneumatic tube system. Results.—No statistically significant differences were observed for routine complete blood cell count and white cell differential parameters or markers of platelet activation, such as the mean platelet component, or of red cell fragmentation. When 2 donors who reported aspirin intake were excluded from the analysis, there was a statistically, but not clinically, significant impact of transport through the pneumatic tube system on the mean platelet component. There were no statistically significant differences for prothrombin time, activated partial thromboplastin time, waveform slopes for prothrombin time or activated partial thromboplastin time, fibrinogen, or fibrin monomers. Conclusions.—Although further study regarding the mean platelet component may be required, transport through a pneumatic tube system has no clinically significant effect on hematology and coagulation results obtained with certain modern instruments in blood samples from healthy volunteers.


1982 ◽  
Vol 47 (02) ◽  
pp. 101-103 ◽  
Author(s):  
Powers Peterson ◽  
Eugene L Gottfried

SummaryThe results of determinations of the prothrombin time (PT) and the activated partial thromboplastin time (aPTT) are frequently used to assess hemostatic function. Accurate results for these laboratory tests depend on many variables, one of which is the ratio of plasma to anticoagulant. We studied 12 patients and 4 normal subjects to determine the effects of sample volume on PT and aPTT. We conclude that underfilling may produce profound effects, particularly on the aPTT. In contrast, overfilling rarely affects the results. The greatest effects of sample volume were observed in specimens in which the true PT or aPTT was elevated. A normal PT or aPTT result on any specimen, regardless of sample volume, strongly suggests that the true value is normal.


2021 ◽  
Vol 11 (6-S) ◽  
pp. 114-122
Author(s):  
Tahia Jafar Abdo Alhakam Eshag ◽  
Maye M. Merghani ◽  
Nihad Elsadig Babiker

Background: Coagulation, also known as blood clotting, is the process by which blood convert from a liquid to a gel, forming a blood clot. It referred to haemostasis, the stopping of blood loss from a damaged vessel, followed by repair. Material and methods: This was cross sectional study conducted at the albawasla medical laboratory, Khartoum, Sudan during the period August to November, 2021 and to evaluate the effect of time and hemolysis on prothrombin time and activated partial thromboplastin time tests. 50 samples (case group) were collected from the patients attending police teaching hospital   and requested to the PT and APTT test in addition to that,50 apparently healthy donors with no history of any coagulation problems or any chronic disease were selected as control group. Three ml of venous blood samples were collected in container with Tri Sodium Citrate anticoagulant. The coagulation tests (PT and APTT) were performed using semiautomatic device (coagulometer machine MI). Results:  The result of this study revealed that; when compared the measurement of PT and APTT immediately and after one hour there was insignificant differences (p. v.>0.05).  also when compared the measurement of PT and APTT between hemolyzed and non-hemolyzed samples there was significant differences ( p. v.<0.05)  in addition when compared case and control for the PT and APTT immediately,  after one hour, hemolyzed and non-hemolyzed sample there was significant differences ( p. v.<0.05) except the APTT hemolyzed samples  and  insignificant differences with age and gender ( p. v.>0.05).  For the correlation there was significant correlation in the case group for the PT and APTT immediately, after one hour, and hemolyzed samples. Conclusion: In the cases group results showed insignificant differences in the results of PT and APTT between immediate sample and after 1 hour in and significant differences in the results of PT and APTT between hemolyzed and non-hemolyzed samples, also there was insignificant differences between age and gender, immediately, after one hr. and hemolyzed sample in PT and APTT. Keywords:  Homeostasis,  hemolyzed  sample, PT and APTT


1994 ◽  
Vol 3 (1) ◽  
pp. 16-22 ◽  
Author(s):  
CJ Laxson ◽  
MG Titler

How much blood must be discarded from a heparinized arterial line to obtain accurate coagulation studies, specifically activated partial thromboplastin time? The published literature provides insight into the question and guidelines for practice in adult critical care. This article reviews and integrates findings from 14 research studies published from 1971 to 1993 on discarding blood from arterial lines for coagulation studies. Investigators compared activated partial thromboplastin time values from arterial and venous blood samples using various discard volumes, sites and sizes of catheters, and heparin flush concentrations. Similarities and differences in arterial and venous activated partial thromboplastin time were reported. Studies have demonstrated that adequate discard volume for activated partial thromboplastin time is 6 times the catheter dead space. These results should not be generalized to systemically heparinized patients, pediatric patients, or other types of heparinized lines such as pulmonary artery, central venous, or Hickman catheters.


Author(s):  
Somia Attaelseed Hassan ◽  
Zeinab Sayed Abdelaziz ◽  
Mohammed Mobarak Elbasheir ◽  
Wala Eldin Osma Elradi ◽  
Elharam Ibrahim Abd Allah ◽  
...  

Background: Scientists have used herbs nowadays for curing many diseases because they are safer and to overcome the side effect of the chemical drugs. Grape is one of the ancient herbs that used for diseases of the heart and blood vessels, high blood pressure, high cholesterol, skin care and many other conditions. Grape seeds have significantly higher concentrations of polyphenols which has anticoagulant and antithrombotic effect. Materials and Methods: In this study 20 normal blood samples from healthy individuals with age range (19-38) years were enrolled in this study]. Prothrombin time (PT) and activated partial thromboplastin time (APTT) tests were performed before adding grape seed extraction (GSE) (as control) and after adding GSE with different concentrations (25%, 50% and 75%). Results: The results revealed that grape seed extract has an anticoagulant effect as proven by the increase of Prothrombin time and Activated partial thromboplastin time results of the blood samples in different concentrations of the extract. The GSE showed a high statistical significant (P= 0.000) in all concentrations of both PT and APTT tests. Conclusion: This study suggests that GSE has a strong anticoagulant effect; so it can potentially be used as a supplementary anticoagulant agent to prevent thrombosis and cardiovascular diseases.


Author(s):  
Э.М. Гаглоева ◽  
В.Б. Брин ◽  
С.В. Скупневский ◽  
Н.В. Боциева ◽  
Т.В. Молдован

Цель исследования - изучить состояние системы гемостаза при хронической интоксикации хлоридом никеля, исследовать взаимосвязь показателей гемокоагуляции с процессами липопероксидации у крыс в эксперименте. Методика. Опыты проводили на крысах-самцах Вистар (n=50, 230-250 г). Раствор NiCl2 (5 мг/кг) вводили внутрижелудочно ежедневно в течение 2 нед, 1 и 2 мес. По завершении эксперимента исследовали состояние тромбоцитарного и коагуляционного звеньев гемостаза, антикоагулянтную и фибринолитическую активность крови, а также определяли активность процессов перекисного окисления липидов и антиоксидантных ферментов. Результаты. Установлено, что через 2 нед и 1 мес интоксикации у крыс отмечались гиперкоагуляционные изменения показателей свертывающей системы крови: повышение агрегационной активности тромбоцитов, увеличение концентрации фибриногена, снижение активированного частичного тромбопластинового времени (АЧТВ) и протромбинового времени. В этот период регистрировалось увеличение антитромбиновой и фибринолитической активности крови. Через 2 мес наблюдалось подавление активности клеточного звена гемостаза - тромбоцитопения, ослабление степени АДФ-индуцируемой агрегации тромбоцитов. Выявлялась тенденция к уменьшению концентрации фибриногена. На фоне снижения АЧТВ и тромбинового времени отмечалось увеличение протромбинового времени. В то же время регистрировалось угнетение противосвертывающего звена системы гемостаза (снижалась активность антитромбина III), наблюдалось истощение резервных возможностей фибринолитического звена (замедление фXIIа-зависимого эуглобулинового лизиса) и увеличение содержания растворимых фибрин мономерных комплексов, что свидетельствует о наличии тромбинемии. Через 2 нед, один и два месяца интоксикации у животных выявлялись корреляционные связи между основными показателями системы гемостаза и активностью процессов перекисного окисления липидов и антиоксидантных ферментов. Заключение. Полученные данные подтверждают наличие взаимосвязи активности процессов липопероксидации и системы гемостаза, в том числе при хронической никелевой интоксикации. Результаты исследования позволяют рекомендовать применение антиоксидантов для разработки способов коррекции гемостатических сдвигов при воздействии на организм тяжелых металлов. The aim. To study the state of the hemostasis system in chronic nickel intoxication and to investigate the relationship between hemocoagulation indices and lipoperoxidation processes in rats. Methods. Experiments were carried out on male Wistar rats (n=50, 230-250 g). A solution of nickel chloride (5 mg/kg) was administered daily intragastrically for two weeks, one and two months. At the end of the experiments, indices of platelet and coagulation hemostasis systems, anticoagulant and fibrinolytic activity of blood plasma, and activities of lipid peroxidation and antioxidant enzymes were studied. Results. Hypercoagulative changes in indices of the coagulation system were observed in rats after two weeks and one month of intoxication, including increased platelet aggregation and fibrinogen concentration and shortened activated partial thromboplastin time and prothrombin time. During the same period, increased antithrombin and fibrinolytic activities were observed. The depressed activity of the cellular component of hemostasis evident as thrombocytopenia and impaired ADP-induced platelet aggregation was detected after two months of intoxication. A tendency to decrease in fibrinogen concentration was observed. The shortened activated partial thromboplastin time and thrombin time were associated with prolonged prothrombin time. At the same time, inhibition of the anticoagulant component of hemostasis (decreased antithrombin III activity), exhaustion of the fibrinolysis system reserve (delayed fXIIa-dependent euglobulin lysis), and a significant increase in soluble fibrin monomeric complexes indicative of thrombinemia were observed. After two weeks, one and two months of nickel intoxication, a correlation was found between the major indices of the hemostasis system and the activities of lipid peroxidation and antioxidant enzymes. Conclusion. The study confirmed a relationship between the lipid peroxidation activity and the hemostasis system, specifically in chronic nickel intoxication. This result allows to recommend the use of antioxidants in developing methods for correction of hemostatic induced affected by heavy metals.


Sign in / Sign up

Export Citation Format

Share Document