scholarly journals The comparison of bolus tracking and test bolus techniques for computed tomography thoracic angiography in healthy beagles

Author(s):  
Nicolette Cassel ◽  
Ann Carstens ◽  
Pieter Becker

Computed tomography thoracic angiography studies were performed on five adult beagles using the bolus tracking (BT) technique and the test bolus (TB) technique, which were performed at least two weeks apart. For the BT technique, 2 mL/kg of 300 mgI/mL iodinated contrast agent was injected intravenously. Scans were initiated when the contrast in the aorta reached 150 Hounsfield units (HU). For the TB technique, the dogs received a test dose of 15% of 2 mL/kg of 300 mgI/mL iodinated contrast agent, followed by a series of low dose sequential scans. The full dose of the contrast agent was then administered and the scans were conducted at optimal times as identified from time attenuation curves. Mean attenuation in HU was measured in the aorta (Ao) and right caudal pulmonary artery (rCPA). Additional observations included the study duration, milliAmpere (mA), computed tomography dose index volume (CTDI[vol]) and dose length product (DLP). The attenuation in the Ao (BT = 660 52 HU ± 138 49 HU, TB = 469 82 HU ± 199 52 HU, p = 0.13) and in the rCPA (BT = 606 34 HU ± 143 37 HU, TB = 413 72 HU ± 174.99 HU, p = 0.28) did not differ significantly between the two techniques. The BT technique was conducted in a significantly shorter time period than the TB technique (p = 0.03). The mean mA for the BT technique was significantly lower than the TB technique (p = 0.03), as was the mean CTDI(vol) (p = 0.001). The mean DLP did not differ significantly between the two techniques (p = 0.17). No preference was given to either technique when evaluating the Ao or rCPA but the BT technique was shown to be shorter in duration and resulted in less DLP than the TB technique.

PLoS ONE ◽  
2012 ◽  
Vol 7 (4) ◽  
pp. e34496 ◽  
Author(s):  
Cristian T. Badea ◽  
Khannan K. Athreya ◽  
Gabriela Espinosa ◽  
Darin Clark ◽  
A. Paiman Ghafoori ◽  
...  

2015 ◽  
Vol 21 (1) ◽  
pp. 7-12
Author(s):  
Emilia Wyszomierska ◽  
Ewa Pasieka ◽  
Robert Milewski ◽  
Urszula Łebkowska

2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Anwuli Christiana Tobi ◽  
Chukwuka Emmanuel Mokobia ◽  
Joyce Ekeme Ikubor ◽  
Akintayo Daniel Omojola

Purpose: The aim of this study was to determine the mean volume computed tomography dose index (CTDIvol) for the standard head and body phantoms and locally designed head and body phantoms respectively. Similarly, this study determined and compared the displayed mean CTDIvol and Dose Length Product (DLP) for the above phantoms from the CT monitor. In addition, the percentage deviations of both phantoms were compared with the recommended limits from the International Atomic Energy Agency (IAEA) and the American College of Radiologists (ACR). Materials and Methods: Dose measurements were made using a standard polymethymethacrylate (PMMA) phantom for head and body as well as a locally designed phantom with four CT scanners using thermoluminescence dosimeters (TLDs). The locally designed phantoms were made using a PMMA sheet, which was bent to give the desired cylindrical shape and was made like the standard phantoms. The constructed phantom was filled with water and the TLD chips were inserted into the center and peripheries of the phantoms to obtain the absorbed doses. Results: The CTDIvol for the standard head and body phantom for center A was 66.97 and 21.85mGy and for B was 23.39 and 6.29mGy respectively. Similarly, the CTDIvol for the constructed head and body phantom for center A was 63.91 and 19.84mGy and for B was 24.67 and 6.30mGy respectively. The uncertainty between the standard and constructed head phantoms for centers A and B was 4.6 and 5.5% respectively, while that of the standard and constructed body phantoms for centers A and B was 9.2 and 0.0% respectively. The maximum percent deviation from the console CTDIvol and DLP values with the four phantoms for centers A and B was within ±20%. The mean correction factors for the head and body were 0.998 and 1.05 respectively. Conclusion: The uncertainties obtained in this study were within the IAEA and ACR recommended value of ±20%. The constructed phantom proved useful for CT dose measurements.


2020 ◽  
Vol 188 (2) ◽  
pp. 261-269
Author(s):  
Yuta Matsunaga ◽  
Yuya Kondo ◽  
Kenichi Kobayashi ◽  
Masanao Kobayashi ◽  
Kazuyuki Minami ◽  
...  

Abstract The aim of this study was to investigate differences in volume computed tomography dose index (CTDIvol) and dose-length product (DLP) values according to facility size in Japan. A questionnaire survey was sent to 3000 facilities throughout Japan. Data from each facility were collected including bed number, computed tomography (CT) scan parameters employed and the CTDIvol and/or DLP values displayed on the CT scanner during each examination. The CTDIvol and DLP for 11 adult and 6 paediatric CT examinations were surveyed. Comparison of CTDIvol and DLP values of each examination according to facility size revealed key differences in CT dose between small and large facilities. This study highlights the importance of lowering the dose of coronary artery examination with contrast agent in smaller facilities and of lowering the dose of adult and paediatric head CT without contrast agent in larger facilities. The results of this study are valid in Japan.


2020 ◽  
Vol 25 (44) ◽  
pp. 4656-4661 ◽  
Author(s):  
Nikolaos Patelis ◽  
Mikes Doulaptsis ◽  
Stylianos Kykalos ◽  
Eleftherios Spartalis ◽  
Anastasios Maskanakis ◽  
...  

Background: Carbon dioxide (CO2) exists in nature around us. In the middle of the 20th century, the intraluminal injection of CO2 demonstrated similar results to those of Digital Subtraction Angiography (DSA) with an iodinated contrast agent (ICA). Since then, the technology behind CO2 DSA has developed significantly. Objective: The aim of this study is to inform physicians about the unique properties of CO2 and its physiology after intraluminal injection. Methods: An extensive search for English literature on the properties of CO2 and the physiology of intraluminal administration was conducted using Pubmed. Results: There is sufficient literature on the properties of CO2 and the physiology of CO2 DSA. A review of this literature explains what happens to the human organism after the injection of CO2. Conclusions: There is enough evidence that CO2 DSA is both effective, diagnostic and safe, but the properties of CO2 should be taken under consideration as complications occur, although rarely.


Sign in / Sign up

Export Citation Format

Share Document