scholarly journals Effect of soil moisture on trace elements concentrations using portable x-ray fluorescence spectrometer

2017 ◽  
Vol 9 (1) ◽  
pp. 468 ◽  
Author(s):  
H. Sahraoui ◽  
M. Hachicha
2010 ◽  
Vol 59 (1) ◽  
pp. 23-33 ◽  
Author(s):  
Shuhei Yonezawa ◽  
Akiko Hokura ◽  
Kenji Matsuda ◽  
Takeshi Kimoto ◽  
Izumi Nakai

1996 ◽  
Vol 45 (10) ◽  
pp. 933-939 ◽  
Author(s):  
Tatsushi WAKISAKA ◽  
Naoki MORITA ◽  
Masanobu WAKASA ◽  
Shinichi TERADA ◽  
Kazuo NISHIHAGI ◽  
...  

Nafta-Gaz ◽  
2021 ◽  
Vol 77 (4) ◽  
pp. 219-226
Author(s):  
Anna Przelaskowska ◽  
◽  
Urszula Zagórska ◽  
Maja Mroczkowska-Szerszeń ◽  
Konrad Ziemianin ◽  
...  

Many trace elements are associated with organic matter. The total organic carbon (TOC) content can be thus calculated basing on the chemical composition measurements. The aim of the presented paper was to evaluate the possibility of estimating the organic matter amount on the basis of trace elements such as: Ni, Cu, Mo, U, V, Zn, Cr, Sr, Pb and Co, for Silurian black shales. Correlations between individual elements and total organic carbon were analysed. Next, mathematical models allowing to calculate the amount of organic matter based on the content of elements significantly related to TOC were constructed. Both more accurate chemical composition analyses (ICP-MS mass spectrometry method) and measurements of lower detectability performed with portable X-ray fluorescence spectrometer EDXRF were used. The relationships between the content of trace elements and the total organic carbon content TOC were found for such elements as: V, Cu, U, Ni, Mo, Cr (ICP-MS) and V, Cu , Cr and Ni (XRF). Mathematical models allowing for TOC quantification based on trace elements, characterized by determination coefficients R2 from 0.84 to 0.92 (for ICP MS method) and from 0.75 to 0.78 (for XRF method) were obtained with the use of the multiple regression method. The mathematical models allow to calculate the content of organic matter TOC for Silurian black shales on the basis of trace element data obtained by both mass spectrometry ICP-MS and X-ray fluorescence spectrometry EDXRF. The possibility of using measurements made with a portable X-ray fluorescence spectrometer is particularly important. Such measurements are fast and can be carried out on cuttings during the drilling process. Models based on XRF results therefore allow for quick modelling of the TOC content during the drilling process.


2018 ◽  
Vol 47 (6) ◽  
pp. 432-440 ◽  
Author(s):  
Santosh Mirji ◽  
Nagappa M. Badiger ◽  
Kaushik Sanyal ◽  
Suyamindra.S. Kulkarni ◽  
Nand Lal Misra ◽  
...  

Author(s):  
O.T. Woo ◽  
G.J.C. Carpenter

To study the influence of trace elements on the corrosion and hydrogen ingress in Zr-2.5 Nb pressure tube material, buttons of this alloy containing up to 0.83 at% Fe were made by arc-melting. The buttons were then annealed at 973 K for three days, furnace cooled, followed by ≈80% cold-rolling. The microstructure of cold-worked Zr-2.5 at% Nb-0.83 at% Fe (Fig. 1) contained both β-Zr and intermetallic precipitates in the α-Zr grains. The particles were 0.1 to 0.7 μm in size, with shapes ranging from spherical to ellipsoidal and often contained faults. β-Zr appeared either roughly spherical or as irregular elongated patches, often extending to several micrometres.The composition of the intermetallic particles seen in Fig. 1 was determined using Van Cappellen’s extrapolation technique for energy dispersive X-ray analysis of thin metal foils. The method was employed to avoid corrections for absorption and fluorescence via the Cliff-Lorimer equation: CA/CB = kAB · IA/IB, where CA and CB are the concentrations by weight of the elements A and B, and IA and IB are the X-ray intensities; kAB is a proportionality factor.


Author(s):  
D. A. Carpenter ◽  
Ning Gao ◽  
G. J. Havrilla

A monolithic, polycapillary, x-ray optic was adapted to a laboratory-based x-ray microprobe to evaluate the potential of the optic for x-ray micro fluorescence analysis. The polycapillary was capable of collecting x-rays over a 6 degree angle from a point source and focusing them to a spot approximately 40 µm diameter. The high intensities expected from this capillary should be useful for determining and mapping minor to trace elements in materials. Fig. 1 shows a sketch of the capillary with important dimensions.The microprobe had previously been used with straight and with tapered monocapillaries. Alignment of the monocapillaries with the focal spot was accomplished by electromagnetically scanning the focal spot over the beveled anode. With the polycapillary it was also necessary to manually adjust the distance between the focal spot and the polycapillary.The focal distance and focal spot diameter of the polycapillary were determined from a series of edge scans.


Author(s):  
N.M. Novikovskii ◽  
◽  
V.M. Raznomazov ◽  
V.O. Ponomarenko ◽  
D.A. Sarychev ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document