scholarly journals Development of a System for Measurement on Asymmetric Sitting Posture

Author(s):  
Ji-Yong Jung ◽  
Yonggwon Won ◽  
In-Sik Park ◽  
Tae-Kyu Kwon ◽  
Jung-Ja Kim

Sitting posture measurement system using the unstable board with accelerometer was developed. And, postural balance was assessed to determine the effect of asymmetry on sitting posture between patients with pelvic asymmetry and healthy subjects. 10 subjects (pelvic asymmetry patients:5, healthy controls:5) were participated in this study. We performed experiment under static and dynamic sitting condition. Angular variation in the anterior-posterior and left-right direction was measured in both two conditions. Also, intra class correlation coefficient was used to evaluate the reliability of the system. The value of angle of pelvic asymmetry patients was more tilted significantly to the left side than right side during static and dynamic sitting. The reliability of the system was excellent. This paper suggested that a system for measurement on asymmetric sitting posture can be utilized to provide useful information about patients with pelvic asymmetry in rehabilitation medicine. Furthermore, results from this study can be used to develop the new clinical quantitative measurement system.

PLoS ONE ◽  
2020 ◽  
Vol 15 (11) ◽  
pp. e0242490
Author(s):  
Weiwei Xia ◽  
Han Fu ◽  
Haiying Liu ◽  
Fanqi Meng ◽  
Kaifeng Wang

Background The quantitative measurement of current perception threshold (CPT) has been used as a method to assess the function of nerve fibers in neuropathy diseases. The aim of this study was to assess the test-retest reliability measuring CPT using the circular pin electrodes for assessing the function of cutaneous thin nerve fibers. Methods CPT measurement was repeated on two separate days with at least one-week interval in 55 volunteers. Superficial blood flow (SBF) and skin temperature (ST) were measured on the skin in an around area concentric to the circular pin electrodes after the process of finding CPTs. The coefficient of variation (CV) and intra-class correlation coefficient (ICC) were calculated. The correlation between each two of CPT, SBF increment and ST increment was analyzed. Results No significant differences were found for CPT, SBF and ST between two sessions. SBF was found to be significantly increased after the process of finding CPT. CPT values of males were found to be higher than females. SBF increment was found to be positively correlated with ST increment. The ICC values for CPT, SBF and ST were 0.595, 0.852 and 0.728, respectively. The CV values for CPT, SBF and ST were 25.53%, 12.59% and 1.94%, respectively. Conclusions The reliability of CPT measurement using circular pin electrodes is fair, and need consistence of measurements in longitudinal studies.


2021 ◽  
pp. 003151252110365
Author(s):  
Alessandra V. Prieto ◽  
Kênnea Martins Almeida Ayupe ◽  
Ana C. A. Abreu ◽  
Paulo J. B. Gutierres Filho

Improvement in rider mobility represents an important functional gain for people with disabilities undergoing hippotherapy. However, there is no validated measuring instrument to track and document the rider's progress in riding activities. In this study, we aimed to develop and establish validity evidence for an instrument to assess hippotherapy participants’ mobility on horseback. We report on this development through the stages of: (a) content validation, (b) construct validation, (c) inter- and intra-rater reliability and (d) internal consistency analysis. We evaluated its factor structure with exploratory factor analyses, calculated values for inter- and intra-rater reliability using the intra-class correlation coefficient, and calculated its internal consistency using Cronbach's alpha. We followed recommendations by the Guidelines for Reporting Reliability and Agreement Studies. We found good inter-rater reliability (intra-class correlation coefficient – ICC = 0.991–0.999) and good intra-rater reliability (ICC = 0.997–1.0), and there was excellent internal consistency (Cronbach's α = 0.937–0.999). The instrument’s factor structure grouped its three domains into one factor. As this instrument is theoretically consistent and has been found to be appropriate and reliable for its intended use, it is now available for the measurement of horseback mobility among hippotherapy riders.


2000 ◽  
Vol 49 (1) ◽  
pp. 108-113 ◽  
Author(s):  
E. Lou ◽  
N.G. Durdle ◽  
V.J. Raso ◽  
D.L. Hill

Hand Surgery ◽  
2010 ◽  
Vol 15 (02) ◽  
pp. 71-73 ◽  
Author(s):  
Rouin Amirfeyz ◽  
Sanchit Mehendale ◽  
Sarah Tyrrell ◽  
Raj Bhatia ◽  
Ian Leslie ◽  
...  

Katz and Stirrat devised a hand diagram, which uses subjective information from the patient for the diagnosis of carpal tunnel syndrome (CTS). They reported a good result. We tested the inter-observer and intra-observer reliability of this hand diagram. Twenty five consecutive patients with a diagnosis of CTS, 25 with other common hand and wrist problems but CTS and 25 healthy individuals were prospectively recruited. Each patient filled in a hand diagram. Two experienced hand surgeon scored the diagrams blindly on two different sittings four-week apart. The intra-class correlation coefficient (ICC) and Cohen's Kappa were used for intra and inter-observer reliability respectively. The intra-observer agreement was poor (ICC 95% 0.33–0.65) and inter-observer was fair (Kappa = 0.241). This study does not support the use of Katz and Stirrat Hand Diagram for the diagnosis of carpal tunnel syndrome in place if a thorough clinical examination.


2017 ◽  
Vol 30 (10) ◽  
pp. 691 ◽  
Author(s):  
Debora Soccal Schwertner ◽  
Raul Oliveira ◽  
Ana Paula Ramos Marinho ◽  
Magnus Benetti ◽  
Thais Silva Beltrame ◽  
...  

Introduction: The objective of this study was to adapt the Brazilian version, and verify the validity, reliability and internal consistency of the Oliveira questionnaire on low back pain in young people.Material and Methods: The questionnaire was translated from European Portuguese into Brazilian Portuguese by means of translation and re-translation. The validity of the contents was determined by experts who analyzed the clarity and pertinence of the questions. Fifteen young people aged 15 to 18 took part in the pre-test step (qualitative analysis), 40 in the test-retest (reliability) and 679 in the evaluation of internal consistency. The intra-class correlation coefficient and Spearman’s correlation coefficient were used in the reliability analysis (test-retest), and Cronbach’s alpha to determine the internal consistency (stability).Results: In the translation phase the questionnaire was modified and considered suitable, observing similarity and equivalence of the two versions. After being corrected by the experts in the validation of the contents, the instrument was considered suitable and valid, and in the pre-test, the young people suggested some modifications to make the questionnaire more succinct. With respect to reliability, the values for the intra-class correlation coefficient were between 0.512 – acceptable and 1 – excellent and Spearman’s correlation coefficient varied between 0.525 and 1, classifying the instrument as reproducible. The internal consistency was considered acceptable with a 0.757 Cronbach’s alpha.Discussion: The Oliveira questionnaire was choosen since it has been used in several Portuguese studies; moreover, it addresses the need to raise data regarding low back pain and associated risk factors.Conclusions: The Brazilian version of the Oliveira questionnaire on low back pain in young people showed valid and reliable cultural adaptation, with good reliability and stability.


This study aims to test an interactive pedagogical tool using a computer-based learning approach. The purpose of building Multiple Intelligences Activities Flip Module is to increase students’ potentials through their multiple intelligences. The true-experimental study design is used and the samples are randomly selected as control and treatment groups. Pre and post tests are used to measure the effectiveness of this interactive flip module in relations to multiple intelligences significant differences. The findings of the study reveal that the interactive Multiple Intelligences Activity flip module has a high degree of reliability whereby the average measure for Intra-class Correlation Coefficient is .771 with a 95% confidence interval from .520 to .931 (F(9,486)= 4.644, p<.000). Based on MANCOVA test analysis, the researchers have rejected the null hypothesis. The study has demonstrated that the Multiple Intelligence Activity flip module has increased the scores of multiple intelligences tests for treatment groups.


2020 ◽  
Author(s):  
Jie Xu ◽  
Baohua Su ◽  
Wenhui Zhang ◽  
Hao Sun ◽  
Deng Li ◽  
...  

Abstract Background:Cross-table lateral (CL) radiography is aconvenientandfeasible method toassess cup version angle (VA) after total hip arthroplasty; however, the pelvic tilt (PT) may contribute to its measurement inaccuracy.We sought (1) to determinethe effect of the PT on cup version measurement on CL radiography and (2) to develop a method for reducing measurement errors caused by the PT.Methods: Two groups of VAswere measured respectively on 3D simulatedCL images and CL radiographs. Based on the data, we created a corrective formula to convert the radiographic measurements into values approximating the actual VA under a natural pelvic position. The corrected valueswere compared with computed tomography (CT) measurements to verified the corrective formula. Results:There was a high correlation between the measurements and PTs. For each 1-degree increased in the PT, the VA decreased by 0.76° (R²=0.995, p<0.001). The VA measurements corrected by our equation was in high agreement with the CT-measured valueswithreferenceto the corresponding PT (intra-class correlation coefficient [ICC]=0.988, p<0.001), which was in sharp contrast to that without PT control (ICC=0.454, p=0.203).Conclusions: ThePT may contribute to cup version measurement inaccuracies on CL radiography. Our mathematical algorithm can serve as a reliable method to improve the accuracy of CL radiography.


Sports ◽  
2021 ◽  
Vol 9 (10) ◽  
pp. 140
Author(s):  
Arthur E. Lynch ◽  
Robert W. Davies ◽  
Philip M. Jakeman ◽  
Tim Locke ◽  
Joanna M. Allardyce ◽  
...  

This study aimed to investigate the test-retest reliability of peak force in the isometric squat across the strength spectrum using coefficient of variation (CV) and intra-class correlation coefficient (ICC). On two separate days, 59 healthy men (mean (SD) age 23.0 (4.1) years; height 1.79 (0.7) m; body mass 84.0 (15.2) kg) performed three maximal effort isometric squats in two positions (at a 120° and a 90° knee angle). Acceptable reliability was observed at both the 120° (CV = 7.5 (6.7), ICC = 0.960 [0.933, 0.977]) and 90° positions (CV = 9.2 (8.8), ICC = 0.920 [0.865, 0.953]). There was no relationship between peak force in the isometric squat and the test-retest reliability at either the 120° (r = 0.052, p = 0.327) or 90° (r = 0.014, p = 0.613) positions. A subgroup of subjects (n = 17) also completed the isometric squat test at a 65° knee angle. Acceptable reliability was observed in this position (CV = 9.6 (9.3), ICC = 0.916 [0.766, 0.970]) and reliability was comparable to the 120° and 90° positions. Therefore, we deem isometric squat peak force output to be a valid and reliable measure across the strength spectrum and in different isometric squat positions.


Sign in / Sign up

Export Citation Format

Share Document