No More Drop Panels in the Design for Punching Shear in Flat Plates

2020 ◽  
pp. 1-7
Author(s):  
Abdulqader S Najmi ◽  

Punching shear failure at column-slab connection occurs in a brittle manner, which involves the formation of a truncated cone or a truncated pyramid. A set-up of swimmer bars system takes the shape of truncated steel pyramids to counteract the potential truncated pyramids of cracks. Each counteract truncated steel pyramid is formed by swimmer bars will generate four inclined planes intercepting approximately perpendicularly the four inclined planes of the failure truncated pyramid. A reference to a testing program of four square slabs with a concentric column will be used; these were constructed with overall dimensions of 2000 mm by 2000 mm, 150 mm thickness and 140 by 140 mm column in the middle. The results obtained from testing has proved that the efficiency of using swimmer bars system in slab-column connections has increased their punching shear capacity to more than 250% and has decreased their deflection by increasing the stiffness of the slab in the vicinity of the concentrated loads, moreover, the nature of the punching shear failure becomes ductile instead of brittle and obviates sudden failure. The need for drop panels to resist the punching shearing forces becomes unnecessary. The ultimate strength of punching shear is limited by the compression shear failure, which was never measured for the case of punching shear. The gain in ductility can reach levels matching those in flexural behavior.

Author(s):  
V. Kavinkumar ◽  
R. Elangovan

<div><p><em>This research is to study the mechanical properties of Self Compacting Concrete (SCC) as well as punching shear failure of SCC slabs. Self compacting concrete was first invited in 1988 to achieve durable concrete structures .Design of Reinforced concrete slab is often compromised by their ability to resist shear stress at punching shear surface area. The connection between slabs and supporting columns could be susceptible to high shear stress and might cause sudden and brittle failure. Punching shear failure takes the form of truncated pyramid shape. This program includes investigating the effect of SCC, slab thickness on the punching shear behaviour in terms of load-deflection response and ultimate failure load, failure characteristic of punching shear failure (shape of failure zone and size of failure zone) of simply supported slabs of 1000 x 1000 x 50 and 75mm under concentrated load at centre of slab. The slabs are made with both SCC and Conventional concrete (CC). Investigation included two way specimens with different thickness to evaluate the performance of specimen with different thickness and the effect of thickness on punching shear capacity and performance</em>.</p></div>


Author(s):  
Fatma M. Eid ◽  
Tayel Magdy ◽  
Ebada Ahmed

Punching shear failure is a major problem encountered in the design of reinforced concrete flat slabs. The utilization of shear reinforcement via shear studs or other means has become a choice for improving the punching shear capacity. In this study, a new alternative of reinforcement modalities were tested and demonstrated the effect of self-compact concrete on the punching shear capacity, beside that compared between the difference codes to identify the suitable one for determining the position of critical section of punching shear. Nevertheless, in this investigation, the proposed reinforcement system is examined for interior columns only. An experimental work consisting of six specimens: five of them were cast with normal reinforced concrete and one was cast with self-compact strength concrete. The obtained results indicate that the proposed shear reinforcement system has a positive effect in the enhancement of the punching shear capacity of interior slab–column connection of self-compact strength concrete.


2018 ◽  
Vol 162 ◽  
pp. 04025
Author(s):  
Ebada Ahmed ◽  
Boshra Eltaly ◽  
Fatma El-Zhraa ◽  
Magdy Tayel

Punching shear failure is a major problem encountered in the design of reinforced concrete flat slabs. The utilization of shear reinforcement via shear studs or other means has become a choice for improving the punching shear capacity. In this study, a new alternative of reinforcement modalities were tested and demonstrated the effect of self-compact concrete on the punching shear capacity, beside that compared between the difference codes to identify the suitable one for determining the position of critical section of punching shear. Nevertheless, in this investigation, the proposed reinforcement system is examined for interior columns only. An experimental work consisting of six specimens: five of them were cast with normal reinforced concrete and one was cast with self-compact strength concrete. The obtained results indicate that the proposed shear reinforcement system has a positive effect in the enhancement of the punching shear capacity of interior slab–column connection of self-compact strength concrete.


2008 ◽  
Vol 385-387 ◽  
pp. 857-860
Author(s):  
Hyun Ki Choi ◽  
J.S. Kim ◽  
E.S. Jin ◽  
Chang Sik Choi

This research is an experimental study on full-scale interior slab-column connections of flat-plate. Three types of shear reinforcements were proposed to prevent brittle punching shear failure that could result in collapse of whole flat plate structures. A series of four flat plate specimens including a specimen without shear reinforcement and three specimens with the reinforcements was tested. The dimension of the slabs was 2620*2725*180mm and the specimens had a 600*800mm square column at the center of the slabs. The slabs were tested up to failure using monotonic vertical shear forces. The presences of the shear reinforcements substantially increased punching shear capacity and ductility of the interior slab-column connections.


2016 ◽  
Vol 835 ◽  
pp. 450-454
Author(s):  
Dickson Fong Wen Jing ◽  
Lau Teck Leong

This paper reports test results of flat slab cast from micro-concrete and normal concrete subjected to concentric punching shear. Although the punching shear failure mechanism of micro-concrete slabs was very similar to that of normal-concrete slabs, the punching shear capacity is reduced to about 73% due to the reduction in transferred shear stresses across shear cracks by aggregate interlock. Therefore, a shear retention factor of 0.7 is suggested to be applied in estimating the punching shear strength of micro-concrete slabs.


2013 ◽  
Vol 4 (4) ◽  
pp. 259-280 ◽  
Author(s):  
Mehrafarid Ghoreishi ◽  
Ashutosh Bagchi ◽  
Mohamed Sultan

There are a number of benefits associated with two-way concrete flat slab construction for office buildings, parking garages and apartments - for example, reduced formwork, prompt erection, flexibility of partitions, and minimal increase in story heights. However, concrete flat slabs could be quite vulnerable to punching shear failure in the event of a fire. The objective of the present article is to provide a state of the art review of the existing research and the issues associated with concrete flat slabs in fire and elevated temperature. There are a number of experimental and analytical studies on the punching shear behavior of concrete flat slabs in ambient conditions, available in the literature. Based on these studies, it is found that punching shear capacity in ambient condition is affected by many factors, which may not remain constant during a fire exposure. Only a limited number of studies on concrete flat slabs for punching shear failure in fire are available. This paper reviews the available experimental and analytical studies, standards and codes to address the research gap in estimating of punching shear strength of concrete flat slab-column connections without shear reinforcement.


Author(s):  
Tran Xuan Vinh ◽  
Nguyen Trung Hieu ◽  
Pham Xuan Dat ◽  
Nguyen Manh Hung

Currently, RC flat slabs are being used commonly because of their advantages. Punching shear failure is one of the governing failure modes of RC flat slabs without column capital and drop panels. In this paper, the provisions for predicting the punching shear capacity of two-way reinforced concrete (RC) flat slabs without shear reinforcement including ACI 318-19, Eurocode 2 and TCVN 5574:2018 provisions are reviewed by mean of considering the influences of the main parameters (effective depth, compressive strength of concrete, loaded area, reinforcement ratio). A total of 169 test results collected from the literature were used to compare with the provisions. The aim of this study was to evaluate the level of applicability of predicting the punching shear capacity of two-way RC flat slabs according to these provisions. The comparison results indicated that the Eurocode 2 provision provides the most accurate prediction of punching shear capacity of two-way RC flat slabs.


2021 ◽  
Vol 25 (Special) ◽  
pp. 4-115-4-126
Author(s):  
Liwaa Abd Alhussen ◽  
◽  
Layth A. Al-jaberi ◽  
Ra’id F. Abbas ◽  
◽  
...  

The reaction of column to flat slabs may cause what is known as “punching shear stresses” when the stress is normally concentrated within the perimeter around the loaded area. In general, the reinforced concrete slabs are not designed for any shear failure due to the sudden nature of this type of failure. Many solutions can be followed to overcome such issue like increasing the depth of slab and diameter of columns. Increasing the slab thickness may add extensive dead loads and can breaks the economy justifications of this structural member. On the other hand, increasing the diameter of any column may un accepted due to architectural purposes. The high performance concrete is such type of concrete that illustrate high levels of mechanical performance “structural behavior as a consequence” if compared with normal concrete. Due to that, the high performance concrete may give good alternative an exceeds the problem of punching as a result. The basic aim of this study is to propose a brief review regarding this field of research. However, this study is divided to three parts, the first is devoted to view a suitable background about the punching shear capacity of traditional concrete slabs. The second part is registered to view the past experience in reinforced concrete slabs punching capacity and have steel fibers while the second part is devoted to present the state of art concerning the punching shear of high performance concrete slabs.


Polymers ◽  
2020 ◽  
Vol 12 (3) ◽  
pp. 685 ◽  
Author(s):  
Osama Ahmed Mohamed ◽  
Manish Kewalramani ◽  
Rania Khattab

Reinforced concrete flat slabs or flat plates continue to be among the most popular floor systems due to speed of construction and inherent flexibility it offers in relation to locations of partitions. However, flat slab/plate floor systems that are deficient in two-way shear strength are susceptible to brittle failure at a slab–column junction that may propagate and lead to progressive collapse of a larger segment of the structural system. Deficiency in two-way shear strength may be due to design/construction errors, material under-strength, or overload. Fiber reinforced polymer (FRP) composite laminates in the form of sheets and/or strips are used in structurally deficient flat slab systems to enhance the two-way shear capacity, flexural strength, stiffness, and ductility. Glass FRP (GFRP) has been used successfully but carbon FRP (CFRP) sheets/strips/laminates are more commonly used as a practical alternative to other expensive and/or challenging methods such column enlargement. This article reviews the literature on the methodology and effectiveness of utilizing FRP sheets/strips and laminates at the column/slab intersection to enhance punching shear strength of flat slabs.