scholarly journals In vitro Analysis of Shear Bond Strength and Adhesive Remnant Index of Stainless Steel Brackets with Different Adhesive Systems to Enamel

2018 ◽  
Vol 19 (9) ◽  
pp. 1047-1051
Author(s):  
Mukesh Gupta ◽  
Sumitha A David ◽  
A Nishad ◽  
Sudeep C Bhagvandas
2016 ◽  
Vol 21 (6) ◽  
pp. 67-73 ◽  
Author(s):  
Fernanda de Souza Henkin ◽  
Érika de Oliveira Dias de Macêdo ◽  
Karoline da Silva Santos ◽  
Marília Schwarzbach ◽  
Susana Maria Werner Samuel ◽  
...  

ABSTRACT Introduction: There is a great variety of orthodontic brackets in the Brazilian market, and constantly evaluating them is critical for professionals to know their properties, so as to be able to choose which product best suits their clinical practice. Objectives: To evaluate the bond strength and the adhesive remnant index (ARI) of different brands of metal brackets. Material and Methods: A total of 105 bovine incisors were used, and brackets of different brands were bonded to teeth. Seven different bracket brands were tested (MorelliTM, American OrthodonticsTM, TP OrthodonticsTM, Abzil-3MTM, OrthometricTM, TecnidentTM and UNIDENTM). Twenty-four hours after bonding, shear bond strength test was performed; and after debonding, the ARI was determined by using an optical microscope at a 10-fold increase. Results: Mean shear bond strength values ranged from 3.845 ± 3.997 (MorelliTM) to 9.871 ± 5.106 MPa (TecnidentTM). The majority of the ARI index scores was 0 and 1. Conclusion: Among the evaluated brackets, the one with the lowest mean shear bond strength values was MorelliTM. General evaluation of groups indicated that a greater number of bond failure occurred at the enamel/adhesive interface.


2019 ◽  
Vol 5 (2) ◽  
pp. 23-27
Author(s):  
K Premnath ◽  
◽  
Nagaranjani Prakash ◽  
Mohammed Ajmal B ◽  
Syed Ahmed Raheel ◽  
...  

2018 ◽  
Vol 23 (4) ◽  
pp. 43.e1-43.e7 ◽  
Author(s):  
Mohammad Behnaz ◽  
Kazem Dalaie ◽  
Hoori Mirmohammadsadeghi ◽  
Hamed Salehi ◽  
Vahid Rakhshan ◽  
...  

ABSTRACT Introduction: It is recently suggested that titanium dioxide (TiO2) nanoparticles can be added to bracket luting agents in order to reduce bacterial activity and protect the enamel. However, it is not known if this addition can affect the shear bond strength (SBS) below clinically acceptable levels. Therefore, this study examined this matter within a comprehensive setup. Methods: This in vitro experimental study was conducted on 120 extracted human premolars randomly divided into four groups (n=30): in groups 1 and 2, Transbond XT light-cured composite with or without TiO2 was applied on bracket base; in groups 3 and 4, Resilience light-cured composite with or without TiO2 was used. Brackets were bonded to teeth. Specimens in each group (n=30) were divided into three subgroups of 10 each; then incubated at 37°C for one day, one month, or three months. The SBS and adhesive remnant index (ARI) were calculated and compared statistically within groups. Results: The SBS was not significantly different at one day, one month or three months (p>0.05) but composites without TiO2 had a significantly higher mean SBS than composites containing TiO2 (p<0.001). The SBS of Transbond XT was significantly higher than that of Resilience (p<0.001). No significant differences were noted in ARI scores based on the type of composite or addition of TiO2 (p>0.05). Conclusions: Addition of TiO2 nanoparticles to Transbond XT decreased its SBS to the level of SBS of Resilience without TiO2; thus, TiO2 nanoparticles may be added to Transbond XT composite for use in the clinical setting.


2012 ◽  
Vol 83 (1) ◽  
pp. 152-157 ◽  
Author(s):  
Erika L. Silva-Benítez ◽  
Veronica Zavala-Alonso ◽  
Gabriel A. Martinez-Castanon ◽  
Juan P. Loyola-Rodriguez ◽  
Nuria Patiño-Marin ◽  
...  

Abstract Objective: To study the shear bond strength (SBS), sites of failure, and micromorphology of bonded molar tubes used on teeth affected by dental fluorosis. Materials and Methods: This in vitro study included 140 first molars classified according to Dean's index for dental fluorosis. Samples were divided into seven groups: (1) healthy teeth etched for 15 seconds, (2) teeth with moderate fluorosis (MOF) etched for 15 seconds, (3) teeth with MOF etched for 150 seconds, (4) teeth with MOF microabrasion etched for 15 seconds, (5) teeth with severe fluorosis (SEF) etched for 15 seconds, (6) teeth with SEF etched for 150 seconds, and (7) teeth with SEF microabrasion etched for 15 seconds. All samples were incubated and were then submitted to the SBS test and evaluated with the modified adhesive remnant index (ARI) and analyzed by using a scanning electronic microscope. Results: The SBS mean value for healthy enamel was 20 ± 10.2 MPa. For the group with MOF, the etched 150-second mean value was the highest (19 ± 7.6 MPa); for the group with SEF treated with microabrasion and etched for 15 seconds, the mean value was (13 ± 4.1 MPa). Significant differences (P ≤ .05) were found in the ARI between healthy and fluorosed groups. Conclusions: Fluorotic enamel affects the adhesion of bonded molar tubes. The use of overetching in cases of MOF and the combination of microabrasion and etching in SEF provides a suitable adhesion for fixed appliance therapy.


2013 ◽  
Vol 4 (1) ◽  
pp. 6-16 ◽  
Author(s):  
BM Shivalinga ◽  
S Pradeep ◽  
Ravi Shanthraj ◽  
H Jyothi Kiran

ABSTRACT Aim To evaluate and compare shear bond strength (SBS) and debonding characters of the Transbond XT (BisGMA-based composite), Esthet-X flow (flowable composite), Filtek Z-350 (flowable composite). Materials and methods A total of 90 human premolars were divided into group I, Transbond XT (n = 30); group II, Esthet-X flow (n = 30) and group III, Filtek Z-350 (n = 30), the preadjusted edgewise stainless steel premolar brackets were bonded to evaluate the shear bond and debonding properties. Results The results of the statistical analysis comparing the three groups indicated no statistically significant differences between the groups. In general, the SBS with groups I and III exhibited similar bond strength with 11.58 ± 1.3 MPa and 11.07 ± 1.0 MPa respectively. Groups III exhibited least bond strength of 10.7 ± 2 MPa. In modified adhesive remnant index (ARI) the majority of bond failures occurred at enamel-adhesive interface or cohesive type failure in all the three groups. Groups II and III showed increased frequency of score 2, 4 and 5 compared to group I which showed increased frequency of score 0 and 1. Conclusion When considering the SBS and ARI scores obtained, flowable composites can be effectively applied to orthodontic bracket bonding. How to cite this article Pradeep S, Shanthraj R, Kiran HJ, Shivalinga BM. Comparative Evaluation of the Shear Bond Strength and Debonding Properties of a Conventional Composite and Flowable Composites used for Orthodontic Bracket Bonding. World J Dent 2013;4(1):6-16.


2020 ◽  
Vol 2020 ◽  
pp. 1-7
Author(s):  
Mariana Almeida Mello Proença ◽  
Karime Tavares Lima da Silva ◽  
Alisson Costa e Silva ◽  
Edilausson Moreno Carvalho ◽  
José Bauer ◽  
...  

Objectives. The aim of this study was to evaluate the shear bond strength of metal brackets bonded with different universal adhesive systems containing 10-MDP and Transbond Plus Self Etching Primer after 20,000 thermal cycles. Materials and Methods. A total of 130 sound bovine teeth were used, which are divided into 5 groups (n = 26) according to the adhesive system used: All-Bond Universal (Bisco), Ambar Universal (FGM), Clearfil Universal Bond (Kuraray), Single Bond Universal (3M/ESPE), and Transbond Plus SEP (3M/ESPE) as control. The adhesives were applied for 20 seconds and bonded with a resin Transbond XT (3M/ESPE). After this, the teeth were submitted to 20,000 cycles at 5°C and 55°C. Afterwards, the shear bond strength test was performed in a universal test machine (Instron 3342). The adhesive remnant index (ARI) was evaluated under a stereomicroscope at 10x magnification and scanning electronic microscopy (SEM, Hitachi 3030). The shear bond strength data were submitted to One-Way ANOVA (α = 0.05) and the ARI to the Kruskal–Wallis test (α = 0.05). Results. Statistical analysis showed that the universal adhesive systems presented mean shear bond strength values similar to Transbond Plus SEP (p<0.05). The universal adhesive presented similar ARI values among them but differed from those of Transbond Plus SEP (p<0.001). Transbond Plus SEP presented a high ARI value when compared with the universal adhesive systems and high demineralization of enamel. Conclusions. The results show that universal adhesive systems may be used for bonding metal brackets if the orthodontist wants to maintain dental enamel health.


Sign in / Sign up

Export Citation Format

Share Document