scholarly journals Comparison of Custom-Made 3D Printed Bio-Degradable Plates and Titanium Anatomical Plates at Fracture Treatment: A Biomechanical Study

2021 ◽  
Vol 6 (4) ◽  
pp. 285-289
Author(s):  
Mehmet Yalçınozan ◽  
◽  
Emil Mammadov ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 2563
Author(s):  
Ivan Grgić ◽  
Vjekoslav Wertheimer ◽  
Mirko Karakašić ◽  
Željko Ivandić

Recent soft tissue studies have reported issues that occur during experimentation, such as the tissue slipping and rupturing during tensile loads, the lack of standard testing procedure and equipment, the necessity for existing laboratory equipment adaptation, etc. To overcome such issues and fulfil the need for the determination of the biomechanical properties of the human gracilis and the superficial third of the quadriceps tendons, 3D printed clamps with metric thread profile-based geometry were developed. The clamps’ geometry consists of a truncated pyramid pattern, which prevents the tendons from slipping and rupturing. The use of the thread application in the design of the clamp could be used in standard clamping development procedures, unlike in previously custom-made clamps. Fused deposition modeling (FDM) was used as a 3D printing technique, together with polylactic acid (PLA), which was used as a material for clamp printing. The design was confirmed and the experiments were conducted by using porcine and human tendons. The findings justify the usage of 3D printing technology for parts manufacturing in the case of tissue testing and establish independence from the existing machine clamp system, since it was possible to print clamps for each prepared specimen and thus reduce the time for experiment setup.


2021 ◽  
pp. 112067212110000
Author(s):  
Annabel LW Groot ◽  
Jelmer S Remmers ◽  
Roel JHM Kloos ◽  
Peerooz Saeed ◽  
Dyonne T Hartong

Purpose: Recurrent contracted sockets are complex situations where previous surgeries have failed, disabling the wear of an ocular prosthesis. A combined method of surgery and long-term fixation using custom-made, three-dimensional (3D) printed conformers is evaluated. Methods: Retrospective case series of nine patients with recurrent excessive socket contraction and inability to wear a prosthesis, caused by chemical burns ( n = 3), fireworks ( n = 3), trauma ( n = 2) and enucleation and radiotherapy at childhood due to optic nerve glioma ( n = 1) with three average previous socket surgeries (range 2–6). Treatment consisted of a buccal mucosal graft and personalized 3D-printed conformer designed to be fixated to the periosteum and tarsal plates for minimal 2 months. Primary outcome was the retention of an ocular prosthesis. Secondary outcome was the need for additional surgeries. Results: Outcomes were measured at final follow-up between 7 and 36 months postoperatively (mean 20 months). Eight cases were able to wear an ocular prosthesis after 2 months. Three cases initially treated for only the upper or only the lower fornix needed subsequent surgery for the opposite fornix for functional reasons. Two cases had later surgery for cosmetic improvement of upper eyelid position. Despite pre-existing lid abnormalities (scar, entropion, lash deficiency), cosmetic outcome was judged highly acceptable in six cases because of symmetric contour and volume, and reasonably acceptable in the remaining two. Conclusions: Buccal mucosal transplant fixated with a personalized 3D-designed conformer enables retention of a well-fitted ocular prosthesis in previously failed socket surgeries. Initial treatment of both upper and lower fornices is recommended to avoid subsequent surgeries for functional reasons.


Metals ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 707
Author(s):  
Jong-Woong Park ◽  
Hyun-Guy Kang ◽  
June-Hyuk Kim ◽  
Han-Soo Kim

In orthopedic oncology, revisional surgery due to mechanical failure or local recurrence is not uncommon following limb salvage surgery using an endoprosthesis. However, due to the lack of clinical experience in limb salvage surgery using 3D-printed custom-made implants, there have been no reports of revision limb salvage surgery using a 3D-printed implant. Herein, we present two cases of representative revision limb salvage surgeries that utilized another 3D-printed custom-made implant while retaining the previous 3D-printed custom-made implant. A 3D-printed connector implant was used to connect the previous 3D-printed implant to the proximal ulna of a 40-year-old man and to the femur of a 69-year-old woman. The connector bodies for the two junctions of the previous implant and the remaining host bone were designed for the most functional position or angle by twisting or tilting. Using the previous 3D-printed implant as a taper, the 3D-printed connector was used to encase the outside of the previous implant. The gap between the previous implant and the new one was subsequently filled with bone cement. For both the upper and lower extremities, the 3D-printed connector showed stable reconstruction and excellent functional outcomes (Musculoskeletal Tumor Society scores of 87% and 100%, respectively) in the short-term follow-up. To retain the previous 3D-printed implant during revision limb salvage surgery, an additional 3D-printed implant may be a feasible surgical option.


2021 ◽  
Vol 10 (5) ◽  
pp. 1056
Author(s):  
Giovanni Beltrami ◽  
Gabriele Ristori ◽  
Anna Maria Nucci ◽  
Alberto Galeotti ◽  
Angela Tamburini ◽  
...  

Recently, custom-made 3D-printed prostheses have been introduced for limb salvage surgery in adult patients, but their use has not been described in pediatric patients. A series of 11 pediatric patients (mean age 10.8 years; range 2–13) with skeletal tumors treated with custom-made implants for the reconstruction of bony defects is described. Patients were followed up every 3 months. Functional results were evaluated by the Musculoskeletal Tumor Society Score (MSTS) for upper and lower limbs. The mean follow-up was 25.7 months (range 14–44). Three patients died after a mean of 19.3 months postoperatively—two because of disease progression and the other from a previous malignancy. Three patients experienced complications related to soft tissues. One patient required device removal, debridement, and antibiotic pearls for postoperative infection. Partial osseointegration between grafts and host bone was observed within a mean of 4 months. At the final follow-up, mean MSTS score was 75%. 3D prostheses may yield biological advantages due to possible integration with the host bone and also through the use of vascularized flaps. Further research is warranted.


2018 ◽  
Vol 66 (2) ◽  
pp. e27522 ◽  
Author(s):  
Xiang Fang ◽  
Wenli Zhang ◽  
Zeping Yu ◽  
Hongyuan Liu ◽  
Yan Xiong ◽  
...  

2021 ◽  
Vol 19 (1) ◽  
Author(s):  
Jie Wang ◽  
Jingjing An ◽  
Minxun Lu ◽  
Yuqi Zhang ◽  
Jingqi Lin ◽  
...  

Abstract Background Long-lasting reconstruction after extensive resection involving peri-knee metaphysis is a challenging problem in orthopedic oncology. Various reconstruction methods have been proposed, but they are characterized by a high complication rate. The purposes of this study were to (1) assess osseointegration at the bone implant interface and correlated incidence of aseptic loosening; (2) identify complications including infection, endoprosthesis fracture, periprosthetic fracture, leg length discrepancy, and wound healing problem in this case series; and (3) evaluate the short-term function of the patient who received this personalized reconstruction system. Methods Between September 2016 and June 2018, our center treated 15 patients with malignancies arising in the femur or tibia shaft using endoprosthesis with a 3D-printed custom-made stem. Osseointegration and aseptic loosening were assessed with digital tomosynthesis. Complications were recorded by reviewing the patients’ records. The function was evaluated with the 1993 version of the Musculoskeletal Tumor Society (MSTS-93) score at a median of 42 (range, 34 to 54) months after reconstruction. Results One patient who experienced early aseptic loosening was managed with immobilization and bisphosphonates infusion. All implants were well osseointegrated at the final follow-up examination. There are two periprosthetic fractures intraoperatively. The wire was applied to assist fixation, and the fracture healed at the latest follow-up. Two patients experienced significant leg length discrepancies. The median MSTS-93 score was 26 (range, 23 to 30). Conclusions A 3D-printed custom-made ultra-short stem with a porous structure provides acceptable early outcomes in patients who received peri-knee metaphyseal reconstruction. With detailed preoperative design and precise intraoperative techniques, the reasonable initial stability benefits osseointegration to osteoconductive porous titanium, and therefore ensures short- and possibly long-term durability. Personalized adaptive endoprosthesis, careful intraoperative operation, and strict follow-up management enable effective prevention and treatment of complications. The functional results in our series were acceptable thanks to reliable fixation in the bone-endoprosthesis interface and an individualized rehabilitation program. These positive results indicate this device series can be a feasible alternative for critical bone defect reconstruction. Nevertheless, longer follow-up is required to determine whether this technique is superior to other forms of fixation.


2016 ◽  
Vol 26 (7) ◽  
pp. 1902-1909 ◽  
Author(s):  
Ran Wei ◽  
Wei Guo ◽  
Tao Ji ◽  
Yidan Zhang ◽  
Haijie Liang

2021 ◽  
Author(s):  
Shira Landau ◽  
Ariel A. Szklanny ◽  
Majd Machour ◽  
Ben Kaplan ◽  
Yulia Shandalov ◽  
...  

Abstract Microtia is a small, malformed external ear, which occurs at an incidence of 1-10 per 10,000 births. Autologous reconstruction using costal cartilage is the most widely accepted surgical microtia repair technique. Yet, the method involves donor-site pain and discomfort and relies on the artistic skill of the surgeon to create an aesthetic ear. This study employed novel tissue engineering techniques to overcome these limitations, by developing a clinical-grade, 3D-printed biodegradable auricle scaffold that formed stable, custom-made, neocartilage implants. The unique scaffold design combined strategically reinforced areas to maintain the complex topography of the outer ear and micropores to allow cell adhesion for the effective production of stable cartilage. The auricle construct was CT scan-based composed of a 3D-printed clinical-grade polycaprolactone (PCL) scaffold loaded with patient‐derived chondrocytes produced from either auricular cartilage or costal cartilage biopsies combined with adipose-derived MSCs. Cartilage formation was measured within the construct in vitro, and cartilage maturation and stabilization were observed 12 weeks after its subcutaneous implantation into a murine model. The proposed technology is simple and effective and is


Polymers ◽  
2020 ◽  
Vol 12 (9) ◽  
pp. 2136
Author(s):  
Eric Luis ◽  
Houwen Matthew Pan ◽  
Anil Kumar Bastola ◽  
Ram Bajpai ◽  
Swee Leong Sing ◽  
...  

Osteoarthritis of the knee with meniscal pathologies is a severe meniscal pathology suffered by the aging population worldwide. However, conventional meniscal substitutes are not 3D-printable and lack the customizability of 3D printed implants and are not mechanically robust enough for human implantation. Similarly, 3D printed hydrogel scaffolds suffer from drawbacks of being mechanically weak and as a result patients are unable to execute immediate post-surgical weight-bearing ambulation and rehabilitation. To solve this problem, we have developed a 3D silicone meniscus implant which is (1) cytocompatible, (2) resistant to cyclic loading and mechanically similar to native meniscus, and (3) directly 3D printable. The main focus of this study is to determine whether the purity, composition, structure, dimensions and mechanical properties of silicone implants are affected by the use of a custom-made in-house 3D-printer. We have used the phosphate buffer saline (PBS) absorption test, Fourier transform infrared (FTIR) spectroscopy, surface profilometry, thermo-gravimetric analysis (TGA), X-ray photoelectron spectroscopy (XPS), differential scanning calorimetry (DSC), and scanning electron microscopy (SEM) to effectively assess and compare material properties between molded and 3D printed silicone samples.


Author(s):  
L Maslov ◽  
M Zhmaylo ◽  
I Maslova ◽  
S Purkova ◽  
F Tarasenko ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document