scholarly journals Synthesis of metal organic framework (MOF-5) embedded cryogel composite and its application for the extraction and determination of cholesterol from milk samples

2021 ◽  
Vol 12 (1) ◽  
pp. 45-51
Author(s):  
Fouzia Chang ◽  
Najma Memon ◽  
Huma Shaikh ◽  
Ayaz Ali Memon ◽  
Shahabuddin Memon ◽  
...  

Metal-organic frameworks (MOFs)/coordination polymers (CPs) are a new class of hybrid inorganic/organic porous material. Recently MOFs have attracted much attention due to their large surface area, tunable pore structure, and high thermal stability. MOF-5 is composed of zinc salt and 1,4 benzene dicarboxylic linker. In the current study, MOF-5/cryogel composite was applied to extract cholesterol selectively from milk samples. This extraction process was used to clean-up milk samples with MOF-5/cryogel composite followed by determination of cholesterol in milk using UV-Vis spectrophotometric technique. The parameters such as concentration of cholesterol, volume of cholesterol solution, adsorbent amount, adsorption and desorption time were studied to obtain good extraction of cholesterol. The amount of cholesterol adsorbed and desorbed was 84 and 80%, respectively, from milk samples using MOF-5 composite cryogel. The developed method was validated in terms of linearity, accuracy, precision, limit of detection, and quantification. The response was linear in the range of 5-200 µg/mL with a coefficient of determination (r2) of 0.990. Detection limit (0.15 µg/mL) and quantification (0.45 µg/mL) were obtained.

Author(s):  
Lien Le Thi ◽  
Anh Bach Thuy ◽  
Khanh Cao Cong ◽  
Ha Tran Nguyen ◽  
Hong Hao Le Thi ◽  
...  

The determination of crinamidine in dietary supplements content by mass spectrometry (GC-MS/MS) was developed and validated. The method was performed on the DB5MS column (30m x 0,25mm; 0,25 μm), in combination with the tandem mass spectrometry. The parameters of the method were evaluated for selectivity, calibration curve, accuracy, precision, limit of detection (LOD) and limit of quantification (LOQ). The calibration curve was highly linear (the coefficient of determination 0.9970) within the concentration range of 5ppm-50ppm. The recovery at three concentrations were above 90,1%. The limit of detection (LOD) and limit of quantification (LOQ) of the methods were 3 and 10 mg/kg, respectively. All obtained results were acceptable according to the AOAC for dietary supplements. The method was applied to analyze 34 samples in Hanoi.


Author(s):  
Yuning Jiang ◽  
Yanzheng Cai ◽  
Sen Hu ◽  
Xiaoyu Guo ◽  
Ye Ying ◽  
...  

Creatinine level in urine is an important biomarker for renal function diseases, such as renal failure, glomerulonephritis, and chronic nephritis. The Au@MIL-101(Fe) was prepared by in situ growth of Au nanoparticles in MIL-101(Fe) as a selective SERS substrate. The Au@MIL-101(Fe) offers the great local surface plasmon resonance (SPR) effect due to gold nanoparticles aggregation inside metal-organic frameworks. The framework structure could enrich trace target samples and drag them into SPR hot spots. The optimal Au@MIL-101(Fe) composite substrate is used for analyzing creatinine in urine and the limit of detection is down to 0.1[Formula: see text][Formula: see text]mol/L and a linear relationship is ranging from 1[Formula: see text][Formula: see text]mol/L to 100[Formula: see text][Formula: see text]mol/L.


2021 ◽  
Author(s):  
Naeime Salandari-Jolge ◽  
Ali A. Ensafi ◽  
Behzad Rezaei

Dipyridamole is a prescribed medication used to treat cardiovascular diseases, angina pectoris, imaging tests for heart patients, and myocardial infarction. Therefore, high selectivity and sensitivity, low cost, and high-performance speed...


Sign in / Sign up

Export Citation Format

Share Document