Pilot-scale injection of colloidal activated carbon for PFAS immobilization at a contaminated field site

Author(s):  
Fritjof Fagerlund ◽  
Georgios Niarchos ◽  
Lutz Ahrens ◽  
Dan Berggren Kleja ◽  
Jonny Bergman ◽  
...  

<p>Per- and polyfluorinated alkyl substances (PFASs) are extremely recalcitrant contaminants that pose a challenge for remediation in soil and groundwater due to their chemical stability and resistance to degradation. They are used in numerous consumer products and their use in firefighting aqueous-film-forming foams has led to worldwide contamination of groundwater resources associated with airports and firefighting training areas. One of the currently most promising in-situ treatment techniques is stabilization using activated carbon (AC) sorbents that can immobilize PFASs in the soil and prevent further spreading from a contaminated site. However, few documented field studies exist.</p><p>In this study we investigated in-situ stabilization of PFASs by injection of colloidal activated carbon (CAC, PlumeStop®) at a PFAS contaminated site in Arboga, Sweden. Prior to the design of the pilot-scale test and CAC injection, the geology and state of contamination were carefully characterized and PFAS concentrations and groundwater levels were monitored continuously for almost one year. CAC was injected to create a defined zone of PFAS-sorption where PFASs from the contaminant plume would be sorbed to CAC and removed from the flowing groundwater, similar to a permeable reactive barrier. The effect of the injected CAC was studied by monitoring PFAS concentrations in the groundwater up- and down-gradient as well as within the CAC barrier both before and after injection. General water chemistry and groundwater levels were also monitored.</p><p>The site characterization showed that there are two distinct source zones of PFAS contamination with different contamination signatures. Continuous baseline monitoring prior to CAC injection did not show any major changes in PFAS concentrations, but revealed seasonal variations in the groundwater levels and flow patterns, leading to seasonal changes also in the direction of contaminant transport. The CAC injection pilot-scale test was therefore designed to shield the down-gradient evaluation wells in small part of the plume accounting for seasonal changes. The geological setting of the site mainly is clayey till soil of relatively low hydraulic conductivity on top of crystalline bedrock, but there are also high permeability flow paths. The low-pressure CAC injections were hence designed and adapted to avoid excessive preferential flow of CAC and achieve a good distribution of CAC in the intended treatment zone (barrier).</p><p>Preliminary results from the monitoring showed strong reduction of all measured PFASs within and directly down-gradient of the CAC barrier. These results indicate that the installation of the CAC barrier was successful despite a relatively complex geological setting where fast preferential flow paths exist. The continuing monitoring will show how the CAC performs over time.</p>

2021 ◽  
Author(s):  
Fritjof Fagerlund ◽  
Georgios Niarchos ◽  
Lutz Ahrens ◽  
Dan Berggren Kleja ◽  
Jonny Bergman ◽  
...  

<p>Due to the exceptional persistence and resistance to degradation of per- and polyfluoroalkyl substances (PFASs), novel technologies for in-situ treatment and remediation of these pollutants are urgently needed. While there is still a need for more evidence from well-documented field applications, a promising technique is the use of activated carbon (AC) sorbents that can immobilize PFASs in groundwater and thereby prevent further spreading of the contaminants.</p><p>In Arboga Sweden a small fire-fighting training area connected to aviation industry is contaminated by PFAS from aqueous film forming foams (AFFFs). This site has been characterized for PFAS contamination and hydrogeological parameters affecting the spreading of contaminants with the groundwater in a few smaller site investigations since 2016 and continuous monitoring since 2018. In November 2019 colloidal activated carbon (CAC) was injected in a pilot-scale test to study the capability of CAC to immobilize PFASs in a part of the contamination plume.</p><p>The complex geology of the site made the injection of CAC challenging and special measures had to be taken to avoid excessive preferential flow of the CAC particles even at low-pressure injection. The injection pattern was modified and CaCl<sub>2</sub> was injected downstream of the CAC injection to reduce CAC mobility and create a defined zone of CAC intercepting the PFAS plume in the groundwater, thus acting like a PFAS-immobilizing permeable barrier.</p><p>PFAS concentrations were initially reduced by 74% (for a sum of 11 PFASs) directly downstream of the CAC-barrier. However, a few months later PFAS concentrations rebounded to levels equally high or higher than before CAC injection, after which the levels have been going down again. The reasons to the rebound are likely connected to seasonal changes and fluctuations in the groundwater flow directions, causing bypass of the permeable CAC barrier. Lessons learned from applying CAC injections at this field site include the key importance of understanding the groundwater flow patterns and its temporal variability. CAC was able to produce significant reduction in PFAS concentrations (74%), but only when the PFAS plume was properly intercepted. The results illustrate the challenges with application of permeable barrier techniques particularly at geologically complex field sites. At such sites, sorbents for immobilization of PFAS plumes in groundwater should be applied in the most straightforward location where a year-round interception of the plume can be obtained.</p>


2019 ◽  
Vol 53 (10) ◽  
pp. 6104-6105
Author(s):  
Rayford B. Payne ◽  
Upal Ghosh ◽  
Harold D. May ◽  
Christopher W. Marshall ◽  
Kevin R. Sowers

2013 ◽  
Vol 295-298 ◽  
pp. 1384-1388 ◽  
Author(s):  
Dao Ji Wu ◽  
Xiao Xiang Cheng ◽  
Xue Dong Zhai ◽  
Yan Jie Wang

Aim at experimenting the micro-polluted characteristic of Huaihe River water, a pilot-scale test by the combination process of ozone/ultraviolet (UV) /biological activated carbon (BAC) filter for advanced treatment of drinking water was applied. The removal efficiency of general pollution indexes by combined process with different ozone dosages (1.0~3.0 mg/L) was investigated. Along with the increase of ozone dosage, the removal efficiency of CODMn and UV254 generally increased in ozone/UV oxidation process; The removal effect of NO2--N by ozone/UV oxidation was obvious; The removal of turbidity and NH3-N was mainly in BAC filter phase; When the ozone dosage was 2.0~2.5 mg/L, the general pollution indexes had gotten satisfying results, thus it was not necessary to increase the ozone dosage.


2014 ◽  
Vol 11 (5) ◽  
pp. 525 ◽  
Author(s):  
Karen Wovkulich ◽  
Martin Stute ◽  
Brian J. Mailloux ◽  
Alison R. Keimowitz ◽  
James Ross ◽  
...  

Environmental context Arsenic is one of the most common contaminants at US Superfund sites; therefore, establishing techniques to accelerate As remediation could benefit many sites. In a pilot scale study, we determined that addition of oxalic acid to the subsurface has the potential to increase arsenic release from sediments and possibly improve remediation efficiency by pump and treat techniques. Because pump and treat remediation can require many decades to sufficiently decrease contaminant levels, methods for improving remediation could lead to substantial savings in time and resources. Abstract Arsenic is a prevalent contaminant at a large number of US Superfund sites; establishing techniques that accelerate As remediation could benefit many sites. Hundreds of tonnes of As were released into the environment by the Vineland Chemical Co. in southern New Jersey during its manufacturing lifetime (1949–1994), resulting in extensive contamination of surface and subsurface soils and sediments, groundwater, and the downstream watershed. Despite substantial intervention at this Superfund site, sufficient aquifer clean up could require many decades if based on traditional pump and treat technologies only. Laboratory column experiments have suggested that oxalic acid addition to contaminated aquifer solids could promote significant As release from the solid phase. To evaluate the potential of chemical additions to increase As release in situ and boost treatment efficiency, a forced gradient pilot scale study was conducted on the Vineland site. During spring and summer 2009, oxalic acid and bromide tracer were injected into a small portion (~50m2) of the site for 3 months. Groundwater samples indicate that introduction of oxalic acid led to increased As release. Between 2.9 and 3.6kg of As were removed from the sampled wells as a result of the oxalic acid treatment during the 3-month injection. A comparison of As concentrations on sediment cores collected before and after treatment and analysed using X-ray fluorescence spectroscopy suggested reduction in As concentrations of ~36% (median difference) to 48% (mean difference). Although further study is necessary, the addition of oxalic acid shows potential for accelerating treatment of a highly contaminated site and decreasing the As remediation time-scale.


1998 ◽  
Vol 38 (6) ◽  
pp. 163-169 ◽  
Author(s):  
Wataru Nishijima ◽  
Woo Hang Kim ◽  
Eiji Shoto ◽  
Mitsumasa Okada

The objective of this study is to evaluate removal of DOC and THMFP during long term operation of an ozonation-biological activated carbon (BAC) process. A pilot scale plant with raw water in an eutrophic reservoir for drinking water supply was operated for 910 days. High DOC and THMFP removal were maintained at 36% and 57%, respectively, in the ozonation-BAC process even after saturation of BAC by DOC. DOC and THMFP removal by ozonation were only 8% and 24%, respectively. High DOC and THMFP removal after saturation was due to the increase in biodegradable DOC by ozonation from 7% to 32% and the subsequent biodegradation by bacteria attached on BAC. Although water temperature changed in the range from 5 to 30°C, seasonal changes in DOC and THMFP removal were not observed in the ozonation-BAC process.


2019 ◽  
Vol 53 (5) ◽  
pp. 2626-2634 ◽  
Author(s):  
Rayford B. Payne ◽  
Upal Ghosh ◽  
Harold D. May ◽  
Christopher W. Marshall ◽  
Kevin R. Sowers

Sign in / Sign up

Export Citation Format

Share Document