Modern approaches for the analytical speciation of chromium at very low concentration in waters and leachates

Author(s):  
Manuel Hernandez Cordoba ◽  
Ignacio Lopez-Garcia ◽  
Juan Jose Marín-Hernández ◽  
Maria Jose Muñoz-Sandoval ◽  
Carmen Perez-Sirvent

<p>The speciation of chromium in waters and leachates obtained from soils and sediments has aroused interest in the last years. The element may be present in two oxidation degrees that have quite different toxicity. While chromium (III) is even essential for human beings due to its role in the metabolism of glucose and lipids, Cr(VI) is toxic due to its oxidant properties. The concentration of chromium in waters is usually of a few micrograms per liter, and the difficulty of carrying out the measurement at such low levels is further increased due to the distribution of the total element in the two mentioned forms. The technique commonly used nowadays for the purpose is inductively coupled plasma mass spectrometry (ICP-MS), a powerful analytical tool, but expensive both in acquisition and maintenance. Speciation, in addition, requires some type of previous separation or suitable strategy since the signal obtained by ICP-MS depends on the total amount of the metal present.</p><p>Recent advances in microextraction techniques have demonstrated that the determination and speciation is also possible by using electrothermal atomization atomic absorption spectrometry (ETAAS), an analytical technique which is of lesser cost than ICP-MS and is present in most laboratories worldwide. This communication summarizes some recent studies carried out in our laboratory based on the use of dispersive solid-phase microextraction to concentrate chromium. The small volume of liquid extract finally obtained can be injected into the electrothermal atomizer, and a very sensitive chromium determination is achieved. The extreme sensitivity in this way obtained is the consequence of combining the efficient preconcentration step with the sensitivity inherent to ETAAS measurement. Selectivity is also guaranteed by the characteristics of ETAAS. Speciation can be carried out by means of simple previous redox treatments without the need for a chromatographic separation. Three procedures are compared, one of them using graphene oxide as the active micro-solid phase, other based in the use of cellulose, an inexpensive reagent. Both procedures require a centrifugation step to separate the micro-solid phase from the supernatant. The third procedure uses freshly prepared ferrite particles and avoids the centrifugation step since the magnetic characteristics of the solid material permit an easy separation of phases with an external magnet. In all cases, chromium is measured after desorption from the micro-solid phase by a small volume of a suitable reagent. The limits of detection are close to 0.01 micrograms/L. The reliability of the three procedures is checked by using several reference samples with a certified chromium content. Data for the speciation of the metal are also given, a point that may be of practical interest for those involved in risk assessment or toxicity studies, since the dealers of the reference materials only provide the total chromium content.</p>

2020 ◽  
Vol 16 (4) ◽  
pp. 436-446
Author(s):  
Vallerie A. Muckoya ◽  
Philiswa N. Nomngongo ◽  
Jane C. Ngila

Background: Parabens are synthetic esters used extensively as preservatives and/or bactericides in personal care personal products. Objective: Development and validation of a novel robust chemometric assisted analytical technique with superior analytical performances for the determination of ethylparaben, methylparaben and propylparaben, using simulated wastewater matrix. Methods: An automated Solid Phase Extraction (SPE) method coupled with liquid chromatographymass spectrometry was applied in this study. A gradient elution programme comprising of 0.1% formic acid in deionised water (A) and 0.1% formic acid in Methanol (B) was employed on a 100 x 2.1 mm, 3.0 μm a particle size biphenyl column. Two-level (2k) full factorial design coupled with response surface methodology was used for optimisation and investigation of SPE experimental variables that had the most significant outcome of the analytical response. Results: According to the analysis of variance (ANOVA), sample pH and eluent volume were statistically the most significant parameters. The method developed was validated for accuracy, precision, Limits of Detection (LOD) and Limit of Quantification (LOQ) and linearity. The LOD and LOQ established under those optimised conditions varied between 0.04-0.12 μgL−1 and 0.14-0.40 μgL−1 respectively. The use of matrix-matched external calibration provided extraction recoveries between 78-128% with relative standard deviations at 2-11% for two spike levels (10 and 100 μgL-1) in three different water matrices (simulated wastewater, influent and effluent water). Conclusion: The newly developed method was applied successfully to the analyses of parabens in wastewater samples at different sampling points of a wastewater treatment plant, revealing concentrations of up to 3 μgL−1.


Author(s):  
Lei Xu ◽  
Wen Zhang ◽  
Tao Luo ◽  
Jin-Hui Yang ◽  
Zhaochu Hu

High precise and accurate measurements of Fe isotope ratios for fourteen reference materials from the USGS, MPI-DING and CGSG were successfully carried out using a developed analytical technique by fs...


Author(s):  
Yifeng He ◽  
Man He ◽  
Beibei Chen ◽  
Bin Hu

A novel sulfur-containing functional core-shell magnetic porous organic polymer (Fe3O4@BD-TpMA-S-SH MOPs) was synthesized as magnetic solid phase extraction (MSPE) sorbent for mercury speciation followed by high performance liquid chromatography (HPLC)...


2012 ◽  
Vol 10 (4) ◽  
pp. 1175-1182 ◽  
Author(s):  
Elisaveta Mladenova ◽  
Ivanka Dakova ◽  
Dimiter Tsalev ◽  
Irina Karadjova

AbstractA sorbent L-cysteine grafted silica gel has been evaluated for separation and enrichment of dissolved inorganic i-Hg(II) and methylmercury CH3Hg(I) from surface waters at sub-µg L−1 concentrations. Chemical parameters for mercury species enrichment and separation have been optimized. Analytical schemes for the determination of Hg species, using selective column solid phase extraction (SPE) with continuous flow chemical vapor generation atomic absorption spectrometry (CF-CVG-AAS) or inductively coupled plasma-mass spectrometry (ICP-MS) were developed. Possibilities for on-site SPE enrichment were demonstrated as well. The limits of quantification were 1.5 and 5 ng L−1 for dissolved i-Hg(II) and CH3Hg(I) by CF-CVG-AAS and 1 and 2.5 ng L−1 by ICP-MS with relative standard deviations between 7–12% and 7–14%, respectively. The chemically modified SPE sorbent has demonstrated high regeneration ability, chemical and mechanical stability, acceptable capacity and good enrichment factors. Results for total dissolved mercury were in reasonable agreement with those from independent analyses by direct ICP-MS determinations for river waters and for estuarine water certified reference material.


2018 ◽  
Vol 4 (3) ◽  
Author(s):  
Josefina Pérez-Arantegui ◽  
Francisco Laborda

Abstract Inorganic mass spectrometry has been used as a well-known analytical technique to determine elemental/isotopic composition of very diverse materials, based on the different mass-to-charge ratios of the ions produced in a specific source. In this case, two mass spectrometric techniques are explained and their analytical properties discussed: inductively coupled plasma mass spectrometry (ICP-MS) and thermal ionisation mass spectrometry (TIMS), since they are the most used in art and archaeological material studies. Both techniques combine advantageous analytical properties, like low detection limits, low interferences and high precision. The use of laser ablation as sample introduction system in ICP-MS allows to avoid sample preparation and to perform good spatial-resolution analysis. The development of new instruments, improving the mass separation and the detection of the ions, specially multicollection detectors, results in high-precision isotopic analysis. A summary of the important applications of these mass spectrometric techniques to the analysis of art and archaeological materials is also highlighted.


2015 ◽  
Vol 30 (6) ◽  
pp. 1386-1394 ◽  
Author(s):  
Chao Cui ◽  
Hanyong Peng ◽  
Yanan Zhang ◽  
Kai Nan ◽  
Man He ◽  
...  

Solid phase extraction with Ti-containing mesoporous silica as adsorbent combined with ICP-MS for trace metal analysis in environmental samples.


2018 ◽  
Vol 2018 ◽  
pp. 1-8 ◽  
Author(s):  
Akihide Itoh ◽  
Masato Ono ◽  
Kota Suzuki ◽  
Takumi Yasuda ◽  
Kazuhiko Nakano ◽  
...  

In the present study, ICP-MS with a new hybrid simultaneous preconcentration combining solid phase extraction using chelating resin and iron hydroxide coprecipitation in one batch at a single pH adjustment (pH 6.0) were developed for multielement determination of trace metal ions in seawater. In multielement determination, the present method makes it possible to determine Cr(III), As(V), Se (IV), and other 14 trace metal elements (Ti, V, Co, Ni, Cu, Zn, Zr, Ge, Cd, Sb, Sn, W, Pb, and U) in seawater. Moreover, for speciation analyses of Cr, As, and Se, the pH dependence on recovery for the different chemical forms of Cr, As, and Se was investigated. In speciation analyses, Cr, As, and Se were determined as the total of Cr (III) and a part of Cr (VI), total of As (III) and As (V), and Se(IV), respectively. Determination of total of Se and Cr(VI) remains as future task to improve. Nevertheless, the present method would have possibility to develop as the analytical method to determine comprehensively most metal elements in all standard and guideline values in quality standard in environmental water in Japan, that is, most toxic metal elements in environmental water.


Sign in / Sign up

Export Citation Format

Share Document