Multiple Gas Sensors System for Environmental and Air Quality Assessments - A Way to Perform Environmental Monitoring in Smart Cities

Sensors ◽  
2022 ◽  
Vol 22 (2) ◽  
pp. 502
Author(s):  
Roberta Jacoby Cureau ◽  
Ilaria Pigliautile ◽  
Anna Laura Pisello

The rapid urbanization process brings consequences to urban environments, such poor air quality and the urban heat island issues. Due to these effects, environmental monitoring is gaining attention with the aim of identifying local risks and improving cities’ liveability and resilience. However, these environments are very heterogeneous, and high-spatial-resolution data are needed to identify the intra-urban variations of physical parameters. Recently, wearable sensing techniques have been used to perform microscale monitoring, but they usually focus on one environmental physics domain. This paper presents a new wearable system developed to monitor key multidomain parameters related to the air quality, thermal, and visual domains, on a hyperlocal scale from a pedestrian’s perspective. The system consisted of a set of sensors connected to a control unit settled on a backpack and could be connected via Wi-Fi to any portable equipment. The device was prototyped to guarantee the easy sensors maintenance, and a user-friendly dashboard facilitated a real-time monitoring overview. Several tests were conducted to confirm the reliability of the sensors. The new device will allow comprehensive environmental monitoring and multidomain comfort investigations to be carried out, which can support urban planners to face the negative effects of urbanization and to crowd data sourcing in smart cities.


Author(s):  
Gayatri Doctor ◽  
Payal Patel

Air pollution is a major environmental health problem affecting everyone. An air quality index (AQI) helps disseminate air quality information (almost in real time) about pollutants like PM10, PM2.5, NO2, SO2, CO, O3, etc. In the 2018 environmental performance index (EPI), India ranks 177 out of 180 countries, which indicates a need for awareness about air pollution and air quality monitoring. Out of the 100 smart cities in the Indian Smart City Mission, which is an urban renewal program, many cities have considered the inclusion of smart environment sensors or smart poles with environment sensors as part of their proposals. Internet of things (IoT) environmental monitoring applications can monitor (in near real time) the quality of the air in crowded areas, parks, or any location in the city, and its data can be made publicly available to citizens. The chapter describes some IoT environmental monitoring applications being implemented in some of the smart cities like Surat, Kakinada.


Author(s):  
I. V. May ◽  
A. A. Kokoulina ◽  
S. Yu. Balashov

Introduction. The city of Chita of Zabaikalsky region is one of the cities of Russia, priority on level of pollution of atmosphere. Of the order of 130 impurities emitted by the sources of the city, 12 are monitored at 5 posts of the Roshydromet network. Maximum monthly average concentrations are formed by benz (a) pyrene (up to 56.8 MPC), hydrogen sulfide (12.3 MPC), suspended particles (up to 4PDC), phenol (up to 3.6 MPC). Significant emissions (59.73 thousand tons in 2018) are aggravated by the use of coal as a fuel by heat and power enterprises and the private sector, climatic and geographical features. Within the framework of the Federal project “Clean Air” of the national project “Ecology”, it is envisaged to reduce the gross emission of pollutants into the atmosphere of Chita by 8.75 thousand tons by 2024, which should lead to a significant improvement in the safety and quality of life of citizens. It is necessary to identify the most “risky “components of pollution for health.It is important to understand: whether the environmental monitoring system reflects the real picture of the dangers posed by pollution of the city’s atmosphere; whether there is a need to optimize the monitoring system for the subsequent assessment of the effectiveness and efficiency of measures; what impurities and at what points should be monitored in the interests of the population, administration and economic entities implementing air protection measures.The aim of the study is to develop recommendations for optimizing the program of environmental monitoring of air quality in the city of Chita, taking into account the criteria of danger to public health for the subsequent evaluation of the effectiveness and effectiveness of the Federal project “Clean Air”.Materials and methods. Justification of optimization of monitoring programs was carried out through the calculation of hazard indices, considering: the mass of emissions and toxicological characteristics of each chemical; the population under the influence. A vector map of the city with a layer “population density” was used as a topographic base. The indices were calculated for regular grid cells covering the residential area. For each cell, the repeatability of winds of 8 points from the priority enterprises and the population within the calculated cell were taken into account. As a result, each calculation cell was characterized by a total coefficient, taking into account the danger of potential impacts of emissions. Based on the results of the assessments, recommendations were formulated to optimize the placement of posts in the city and the formation of monitoring programs.Results. Indices of carcinogenic danger to the health of the population of Chita ranged from 584,805. 96 to 0.03 (priorities: carbon (soot), benzene, benz (a) pyrene); indices of non-carcinogenic danger — from 1,443,558. 24 to 0.00 (priorities: sulfur dioxide, inorganic dust containing 70–20% SiO2, fuel oil ash). The greatest danger to public health stationary sources of emissions form in the North-Western, Western and South-Eastern parts of the city. Roshydromet posts in these zones are absent.Conclusions. As part of the objectives of the project “Clean Air”, it is recommended to Supplement the existing state network of observations of atmospheric air quality in Chita with two posts; to include manganese, xylene, vanadium pentoxide in the monitoring programs, to carry out the determination of Benz(a)pyrene et all posts, which will allow to fully and adequately assess the danger of emissions of economic entities, as well as the effectiveness and efficiency of the provided air protection measures.


Atmosphere ◽  
2021 ◽  
Vol 12 (5) ◽  
pp. 647
Author(s):  
Tobias Baur ◽  
Johannes Amann ◽  
Caroline Schultealbert ◽  
Andreas Schütze

More and more metal oxide semiconductor (MOS) gas sensors with digital interfaces are entering the market for indoor air quality (IAQ) monitoring. These sensors are intended to measure volatile organic compounds (VOCs) in indoor air, an important air quality factor. However, their standard operating mode often does not make full use of their true capabilities. More sophisticated operation modes, extensive calibration and advanced data evaluation can significantly improve VOC measurements and, furthermore, achieve selective measurements of single gases or at least types of VOCs. This study provides an overview of the potential and limits of MOS gas sensors for IAQ monitoring using temperature cycled operation (TCO), calibration with randomized exposure and data-based models trained with advanced machine learning. After lab calibration, a commercial digital gas sensor with four different gas-sensitive layers was tested in the field over several weeks. In addition to monitoring normal ambient air, release tests were performed with compounds that were included in the lab calibration, but also with additional VOCs. The tests were accompanied by different analytical systems (GC-MS with Tenax sampling, mobile GC-PID and GC-RCP). The results show quantitative agreement between analytical systems and the MOS gas sensor system. The study shows that MOS sensors are highly suitable for determining the overall VOC concentrations with high temporal resolution and, with some restrictions, also for selective measurements of individual components.


2021 ◽  
Vol MA2021-01 (56) ◽  
pp. 1504-1504
Author(s):  
Tomohiro Kawaguchi ◽  
Hirofumi Inoue ◽  
Akiko Omori ◽  
Masakazu Sai ◽  
Kuniyuki Izawa ◽  
...  

Sensors ◽  
2018 ◽  
Vol 18 (8) ◽  
pp. 2507 ◽  
Author(s):  
Francisco Ramos ◽  
Sergio Trilles ◽  
Andrés Muñoz ◽  
Joaquín Huerta

Nowadays, citizens have a huge concern about the quality of life in their cities, especially regarding the level of pollution. Air quality level is of great importance, not only to plan our activities but also to take precautionary measures for our health. All levels of governments are concerned about it and have built their indexes to measure the air quality level in their countries, regions or cities. Taking into account the existing sensor infrastructure within smart cities, it makes possible to evaluate these indices and to know anywhere the level of pollution in real-time. In this scenario, the main objective of the current work is to foster citizens’ awareness about pollution by offering pollution-free routes. To achieve this goal, a technology-agnostic methodology is presented, which allows for creating pollution-free routes across cities depending on the level of pollution in each zone. The current work includes an extensive study of existing air quality indices, and proposes and carries forward to deployment of the defined methodology in a big city, such as Madrid (Spain).


2009 ◽  
Vol 24 (3) ◽  
pp. 513 ◽  
Author(s):  
María Perevochtchikova

Se ha visto que sin un sistema de monitoreo ambiental integral y eficiente, que propor­cione datos duros de soporte para un diagnóstico de la situación ambiental, no es posible elaborar nuevas políticas públicas para resolver la problemática que enfrentan las áreas urbanas. En el presente trabajo se revisa la situación actual del sistema de monitoreo ambiental de la Zona Metropolitana de la Ciudad de México desde tres ángulos: climatológico, hidrométrico y de calidad de aire. Asimismo se detectan sus principales avances, limitaciones y otras particularidades y al final se complementa el monitoreo ambiental con la parte social y económica. AbstractIt has been proved that without an efficient, integral environmental monitoring system that provides hard back-up data for a diagnosis of the environmental situation, it is impossible to draw up new public policies to solve the problem faced by urban areas. This paper reviews the current status of environmental monitoring in the Mexico City Metropolitan Zone from three angles: climatological, hydrometric and air quality. It also detects the main progress, limitations and other particularities and at the end, environmental monitoring is complemented by the social and economic part.


2016 ◽  
Author(s):  
D. Puglisi ◽  
J. Eriksson ◽  
M. Bastuck ◽  
M. Andersson ◽  
A. Lloyd Spetz ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document