scholarly journals Comparative Evaluation of Marginal Fit of Three Provisional Restorative Materials in Different Mediums: An In-Vitro Study

2021 ◽  
Vol 8 (3) ◽  
pp. 9-14
Author(s):  
Manju Choudhary

Temporaries are used as placeholders before the permanent crowns are installed. If the temporary crown is not fitted properly the tooth can be subject to increased decay and gums can become inflamed causing gingivitis which leads to other more serious problems. A provisional fixed restoration will provide a template for defining tooth contour, esthetics, proximal contacts, ridge contacts and occlusion. Margins made by the indirect technique are considered to be more accurate than those made by the direct technique. The purpose of this in vitro study was to compare the marginal accuracy of provisional crowns made from three different biomaterials using the established indirect method in different environments and to evaluate the effect of water absorption on polymerization shrinkage and the effect of polymerization shrinkage occurring in dry storage for a week. Method:Variables used in this study are: a) Revotek LC-light cured composite b) Protemp II c) poly methyl methacrylate. An aluminium master die was machined with dimensions: 5mm length, 10mm gingival diameter, 5 degree taper, and 1mm shoulder then dental stone die was prepared by making an impression of this experimental model using a poly vinyl siloxane material. Both group A and group B consisted of seven specimens each of DPI, ProtempII, Revotek LC. The specimens were evaluated using measuring microscope (Biolux), which had an eyepiece graticule of 1/10th of an mm. The seven specimens in group A (DPI, ProtempII, Revotek LC) were kept in air at room temperature for one week on the dental stone cast and the readings were tabulated and the mean values were obtained. The seven specimens in group B (DPI, ProtempII, and Revotek LC) were kept in water at room temperature for one week and the readings were tabulated in the same manner and the mean values were obtained. Results: Comparative statistics of the mean values of the specimens kept in air at room temperature showed that DPI had the least marginal discrepancies followed by ProtempII, Revotek LC. The values were highly significant (.002) Comparative statistics of the mean values of the specimens kept in water at room temperature showed that DPI had the least marginal discrepancies followed by Revotek LC, ProtempII. The values were highly significant (.009). Conclusion: After one week in air at room temperature and after one week in water at room temperature DPI recorded the minimal marginal discrepancy. When stored in air at room temperature, DPI had the best marginal adaptation. All of the materials showed evidence of continued polymerization shrinkage after storage in air for a week. Water absorption compensated for polymerization shrinkage in DPI and ProtempII whereas Revotek LC was an exception. Keywords: light cured composite, Protemp II-Bis –acryl composite, poly methyl methacrylate, marginal adaptation, provisional restoration.

2018 ◽  
Vol 4 (4) ◽  
pp. 519-522
Author(s):  
Jeyakumar S ◽  
Jagatheesan Alagesan ◽  
T.S. Muthukumar

Background: Frozen shoulder is disorder of the connective tissue that limits the normal Range of motion of the shoulder in diabetes, frozen shoulder is thought to be caused by changes to the collagen in the shoulder joint as a result of long term Hypoglycemia. Mobilization is a therapeutic movement of the joint. The goal is to restore normal joint motion and rhythm. The use of mobilization with movement for peripheral joints was developed by mulligan. This technique combines a sustained application of manual technique “gliding” force to the joint with concurrent physiologic motion of joint, either actively or passively. This study aims to find out the effects of mobilization with movement and end range mobilization in frozen shoulder in Type I diabetics. Materials and Methods: 30 subjects both male and female, suffering with shoulder pain and clinically diagnosed with frozen shoulder was recruited for the study and divided into two groups with 15 patients each based on convenient sampling method. Group A patients received mobilization with movement and Group B patients received end range mobilization for three weeks. The outcome measurements were SPADI, Functional hand to back scale, abduction range of motion using goniometer and VAS. Results: The mean values of all parameters showed significant differences in group A as compared to group B in terms of decreased pain, increased abduction range and other outcome measures. Conclusion: Based on the results it has been concluded that treating the type 1 diabetic patient with frozen shoulder, mobilization with movement exercise shows better results than end range mobilization in reducing pain and increase functional activities and mobility in frozen shoulder.


Polymers ◽  
2021 ◽  
Vol 13 (10) ◽  
pp. 1660
Author(s):  
Sevda Mihailova Yantcheva

The development of composite materials is subject to the desire to overcome polymerization shrinkage and generated polymerization stress. An indicator characterizing the properties of restorative materials, with specific importance for preventing secondary caries, is the integrity and durability of marginal sealing. It is a reflection of the effects of polymerization shrinkage and generated stress. The present study aimed to evaluate and correlate marginal integrity and micropermeability in second-class cavities restored with three different types of composites, representing different strategies to reduce polymerization shrinkage and stress: nanocomposite, silorane, and bulk-fill composite after a ten-month ageing period. Thirty standardized class ΙΙ cavities were prepared on extracted human molars. Gingival margins were 1 mm apical to the cementoenamel junction. Cavities were randomly divided into three groups, based on the composites used: FiltekUltimate-nanocomposite; Filtek Silorane LS-silorane; SonicFill-bulk-fill composite. All specimens were subjected to thermal cycles after that, dipped in saline for 10-mounds. After ageing, samples were immersed in a 2% methylene blue. Thus prepared, they were covered directly with gold and analyzed on SEM for assessment of marginal seal. When the SEM analysis was completed, the teeth were included into epoxy blocks and cut longitudinally on three slices for each cavity. An assessment of microleakage on stereomicroscope followed. Results were statistically analyzed. For marginal seal evaluation: F.Ultimate and F.Silorane differ statistically with more excellent results than SonicFill for marginal adaptation to the gingival margin, located entirely in the dentin. For microleakage evaluation: F.Ultimate and F.Silorane differ statistically with less microleakage than SonicFill. Based on the results obtained: a strong correlation is found between excellent results for marginal adaptation to the marginal gingival ridge and micropermeability at the direction to the axial wall. We observe a more significant influence of time at the gingival margin of the cavities. There is a significant increase in the presence of marginal fissures (p = 0.001). A significant impact of time (p < 0.000) and of the material (p < 0.000) was found in the analysis of the microleakage.


2020 ◽  
Author(s):  
Obeagu Emmanuel Ifeanyi

The hematological features of Gongronema latifolium, aqueous leaves extract was evaluated using standard methods. After 10 days of consecutive infusions into 9 experimental animals (rabbits). The rabbits were monitored and the following parameters determined; hemoglobin (HB), PCV, Platelet, WBC, Differential White Blood Cell. The Rabbits were grouped into 4, one consisting of control (group A), group B was fed with 0.5 mg/kg, group C with 1.0 mg/kg, and Group D with 1.5mg/kg of the aqueous extract of Gongronemalatifolium. The mean values obtained for hemoglobin estimation for the control group is 5.9 ± 4.1 g/dl, 9.1 ± 2.9 g/dl for group B 10.2 ± 1.8 g/dl for group C and 12.8 ± 0.1 g/dl for group D with no significant increase on the PCV estimation, the mean value for the control (group A) is 17.7 ± 12.3%, 27.3 ± 8.7% for group B, group C (30.6 ± 5.4%) and D (28.4 ± 0.3) show increase that statistically significant (p > 0.01). the platelet counts of group C (600 ± 0 x 109/L) and D(600 ± 0 x 109/L) show significant increase (p > 0.01) when compared with the control (600 ± 00). But the platelet value of group B (550 ± 50 x 109/L) shows no difference. No significant changes were observed in the White Blood Counts of the test groups B (3.5 ± 0.5 x 109/L), C (1.9 + 2.1 x 109/L) and D(3.6 ± 0.4) when compared with the control group (2.9 ± 1.9). The values obtained from the differential White Blood Counts (Neutrophils, Lymphocytes, Eosinophils and Monocytes) were not significant. Therefore, Gongronemalatifolium, when properly taken as a nutritional diet, causes beneficial changes on hemoglobin, packed cell volumes and platelet counts of consumers.


2019 ◽  
Vol 17 (1) ◽  
pp. 228080001881601
Author(s):  
Filiberto Mastrangelo ◽  
Isabella Perraro ◽  
Sabrina Mattia ◽  
Giuseppe Troiano ◽  
Khrystyna Zhurakivska ◽  
...  

Introduction: The technique of sealing is a widely accepted procedure for prevention of caries. The aim of our in vitro study was to compare the effect of two different curing units (traditional LED source and innovative laser diode lamp) on the integrity of fissure sealant material and its interface with tooth enamel. Materials and methods: Sixty healthy third molars were randomly assigned to two groups. In group A were teeth intended for polymerization by LED B lamp, and group B comprised teeth to be polymerized by an innovative laser diode. Both groups were treated with the traditional sealing technique, subjected to a metallization process, and analyzed by scanning electron microscope. Results: Micro-gaps between the sealant and the enamel were found in specimens in both A (43%) and B (40%) groups ( p=0.793), and sealant shrinkage was seen. Significant differences between the groups emerged in the percentage of perimetric micro-erosion sites (80% vs. 100%, p=0.010) and the presence of holes and micro-bubbles on the sealant surface (21% vs. 63%, p=0.001). Conclusions: Although macroscopic clinical polymerization occurred with both instruments, the microscopic evaluation showed significant differences between the studied groups in terms of perimetric micro-erosion sites and micro-bubbles, which were higher in laser-cured samples.


Materials ◽  
2019 ◽  
Vol 12 (11) ◽  
pp. 1833 ◽  
Author(s):  
Rafael Delgado-Ruiz ◽  
Ana Nicolas Silvente ◽  
Georgios Romanos

Implant connections must resist surgical and prosthetic procedures without deformation. This study evaluated the deformation of different internal connections (IC) of narrow dental implants (NDI) after their insertion in artificial dense bone. Thirty NDI, with different IC geometries, Group A (internal hexagon), Group B (tri-channeled), and Group C (four-channeled), with the same length and similar narrow diameters, were inserted in type II density bone blocks. Drilling protocols for dense bone from each implant manufacturer were followed. The Insertion torque (IT), connection length, vertex angles, and wall deformations were analyzed before and after the insertion of the implants. ANOVA (Analysis of Variance) and Tukey post-test were used for statistical comparisons. IT values were higher for Group A, surface damage, and titanium particles were observed in the IC in all the groups. Angle deformations between 5 and 70 degrees were present in all the groups, and the walls of Group B connection were the most affected by deformations (p < 0.05). Within the limitations of this experiment, it can be concluded that narrow diameter implants will suffer deformation of the implant connection and will also experience surface damage and titanium particle release when inserted in type II bone density.


1991 ◽  
Vol 37 (4) ◽  
pp. 504-507 ◽  
Author(s):  
Chizuko Ukita ◽  
Mitsushige Nishikawa ◽  
Akira Shouzu ◽  
Mitsuo Inada

Abstract We developed a simple and highly sensitive RIA for glycated protein (GP), and used it to measure GP in serum and urine from 15 normal controls and 30 diabetics (14 with urinary excretion rate of albumin, Ualb less than 15 micrograms/min, group A; nine with 15 less than or equal to Ualb less than or equal to 150 micrograms/min, group B; and seven with Ualb greater than 150 micrograms/min, group C). The mean serum concentration of GP was above normal in all groups of diabetics, and the mean glycation ratios of serum protein (SGP) were higher in groups B and C than in normal subjects. Urinary concentrations of GP also were increased in groups B and C, although the glycation ratio of urinary protein (UGP) was decreased in group C. Consequently, the selectivity of urinary excretion of GP (UGP/SGP) was significantly decreased in group C. Moreover, there was a significant difference in the mean values of selectivity between groups of patients with various degrees of retinopathy. We suggest that measurements of serum and urinary GP are useful to evaluate the progression of diabetic complications.


2017 ◽  
Vol 05 (01) ◽  
pp. 039-046 ◽  
Author(s):  
Monica Sharma ◽  
Ajay Bansal ◽  
Sunny Panthi ◽  
Shefali Malik ◽  
Atulya Sharma

Abstract Purpose: The purpose of this in vitro study was to evaluate marginal fit of cobalt- chromium (Co-Cr) copings fabricated by direct metal laser sintering system (DMLS) and conventional lost-wax technique (LW). Materials and method: Forty tooth preparations were carried out over extracted mandibular molars. They were divided into two groups A and B of 20 each. For group A Co-Cr copings were fabricated by direct metal laser sintering (DMLS) and for group B by lost wax technique (LW). Glass –ionomer cement (GIC) was used to tack the copings over their preparations. Marginal fit was then evaluated directly under the stereomicroscope. Results: The mean marginal gap of group A was 27.9 ± 2.4 μm and group B was 40.4 ±6 μm. Statistical analysis using t - test showed highly significant difference (P>.05) between the marginal mean of the DMLS (group A) compared to LW (group B). Conclusion: The DMLS copings demonstrated superior marginal fit compared to that of conventional Co-Cr casted copings.


2018 ◽  
Vol 9 (4) ◽  
pp. 254-260 ◽  
Author(s):  
Gholam Ali Gholami ◽  
Milad Karamlou ◽  
Reza Fekrazad ◽  
Farzin Ghanavati ◽  
Neda Hakimiha ◽  
...  

Introduction: Several techniques such as using citric acid, plastic curettes, ultrasonic devices, and lasers have been suggested for debridement of contaminated implant surfaces. This comparative investigation aimed to assess and compare the effects of Er, Cr: YSGG laser and super-saturated citric acid on the debridement of contaminated dental implant surfaces. Methods: In this in-vitro study, 12 contaminated failed implants were collected and randomly divided into 2 groups (6 in group A, and 6 in group B). Also, one implant was considered as the control. The implants were horizontally sectioned into coronal and apical portions and subsequently irradiated by Er, Cr: YSGG laser in coronal and citric acid in apical in group A and the opposite in group B. In order to evaluate the effect of water spray on the laser section, half the laser portion of the implants was irradiated using water, while the other half was irradiated without water with an irradiation time of 1 minute. Results: Results revealed that calculus and plaque removal was greater in the laser part of both groups (with and without water) compared to citric acid parts and the correlation between calculus removal and surface roughness were statistically significant. Furthermore, the surface roughness in the citric acid parts was significantly higher than in laser parts. Water spray during irradiation had a very small influence on understudy factors. Conclusion: Based on the results of this study, the Er, Cr: YSGG laser was more effective in calculus removal and caused less surface roughness compared with citric acid application.


2012 ◽  
Vol 2012 ◽  
pp. 1-5 ◽  
Author(s):  
Basawaraj Biradar ◽  
Sudharani Biradar ◽  
Arvind MS

Objectives. The objective of this in vitro study was to investigate whether weight gain or loss in the three different composites occurs due to water absorption when they are stored in water.Methods. The composite restorative materials selected for this study included a microfine hybrid (Synergy) and two nanofilled composite restorative materials (Ceram X and Filtek Supreme Ultra). Twenty specimens of each material were fabricated of each composite material. Group A: Filtek Supreme Ultra, Group B: Synergy, Group C: Ceram X. Then all the specimens were stored in 10 ml Distilled water containing test tubes and placed in incubator at 37°C for six weeks. The weight changes of these specimens were measured daily for the first week and later once a week for next five weeks by using an electrical analytical balance.Results.The data was analyzed by one-way analysis of variance and Student'sttest. All groups showed maximum amount of water absorption in the first week than gradual decrease in the water absorption from the second to the sixth week, as compared to the first week and there is no statistically significant difference between the groups tested.Conclusion. All the composite restorative material absorbs some amount of water. The water absorption of the composite may decrease the physical and mechanical properties of the composites; hence it is necessary to consider the type of the material before starting the treatment.


2017 ◽  
Vol 8 (3) ◽  
pp. 83-89
Author(s):  
Johnny Holanda De Gauw ◽  
Lara Maria Melo Costa ◽  
Rodrigo Neves Silva ◽  
Natanael Barbosa Santos ◽  
Maria Dânia Holanda Tenorio

Objective: This study aimed to evaluate the effect of ferrous sulfate (FS) on demineralized and non-demineralized human deciduous teeth. Additionally, it was evaluated the penetration extent of FS and its remineralizing effect on the enamel of deciduous teeth using Polarized Light Microscopy (PLM). Method: The sample comprised 44 human deciduous teeth. The 44 crowns were divided randomly into four groups: group A (FS after demineralization), group B (FS without demineralization), group C (only demineralization), and group D (control group). FS at 0.45 mol/L-1 was used daily (15 days) and demineralization was done by pH cycling (7 days). Then, three longitudinal slices of the crowns were photographed using PLM. The degree of penetration of the lesion or stain was measured in micrometers, as well as the distance between the external enamel surface and the core of lesion. Results: Group A showed a dark stain on the outer surface of enamel larger than the group B. It is suggested, a remineralizing effect when comparing groups, A and C. The mean depth and standard deviation for groups A, B, and C were 4.27µm (±1.49), 3.72 µm (±1.68) and 5.00 µm (±1.84), respectively. No dark stains were observed in group D. Conclusion: FS stained the demineralized and non-demineralized human deciduous teeth. However, dark stains in the non-demineralized teeth were smaller or absent, than in the demineralized teeth. Therefore, FS may have a protective effect against demineralization.


Sign in / Sign up

Export Citation Format

Share Document