Perancangan Ulang Tata Letak Fasilitas Gudang Klinik XYZ Menggunakan Metode Dedicated Storage

Author(s):  
Cuincen Faturendra Siboro ◽  
Erni Yusnita

In a warehouse facility layout design including a health clinic, the layout design of warehouse facilities and production storage areas plays a very important role, it is impossible for the manufactured goods to be distributed directly to all customers. For this reason, there is a need for a good storage area and storage system to simplify the production process. Clinic XYZ is a 24-hour public health clinic, located in a sub-district in North Sumatra, to be precise in Medan Deli District. The problem that occurs is the random arrangement of goods in the warehouse without paying attention to storage and arrangement patterns that depend on the position of the empty warehouse. Based on observations, it is known that the time span needed to look for drugs at the clinic is too long, so this will make it difficult for employees / operators to manage the products to be stored or retrieved from the drug warehouse. One of the warehouse design methods that can be used is the dedicated storage method. Dedicated storage is a method of placing a specific location or storage area for each item stored. In this study, the types of drugs were classified into drugs, solid types of drugs, semi-solid drugs, liquid drugs and gas drugs. Based on the results obtained, the number of slots needed in the drug product warehouse is 11 slots, the total floor area needed is 13.2 m2, the area needed for storing medicinal products with an alley area is 6.8 m2, the percentage of area that is not used for storage the product in the medicinal product warehouse is 34% and the diagonal length of the hand truck when carrying the box is 1.56 m.

Author(s):  
Syeda Shafia Zehra ◽  
Aqeel Ur Rahman ◽  
Hammad Armghan ◽  
Iftikhar Ahmad ◽  
Umme Ammara

2020 ◽  
Vol 7 (1) ◽  
Author(s):  
Inês Melo ◽  
João Paulo Neto Torres ◽  
Carlos Alberto Ferreira Fernandes ◽  
Ricardo A. Marques Lameirinhas

2015 ◽  
Vol 9 (7) ◽  
pp. 161
Author(s):  
David Licindo ◽  
Arinne Christin Paramudita ◽  
Renanto Handogo ◽  
Juwari Purwo Sutikno

Carbon capture and storage (CCS) is one of the technologies to reduce greenhouse gas emissions (GHG) tocapture of CO2 from the flue gas of a power plant that typically use coal as a Source of energy and then store it ina suitable geological storage (in specific locations). In practice, these sites may not be readily available forstorage at the same time that the Sources (GHG producing) are operating which gives rise to multi – periodplanning problems. This study presents a mathematical approach by considering constraints limit flowratereceived by Sink, various time availability of Sink and Source and calculation with the purpose to determine theminimum cost network which is getting the maximum load that is exchanged from Source to Sink. Illustrativecase studies are given to demonstrate the application of mathematical models to obtained with the exact result ofthe exchange network from Source to Sink. Derived from network obtained from the calculation of theMaximum Load Source to Sink and results may vary in accordance with the limitations that exist in themathematical model. The case study has been prepared with 2 cases, first 6 Source and 3 Sink with value ofSource Load is greater than the amount available on the Sink. Also, second case is 2 Source and 5 Sinkwithvalue of Source Load is smaller than the amount available on the Sink. In addition, Case Studies tominimize the cost of pipeline construction and distribution of CO2 by plant and storage location determination inJava. Flowrate restriction factor that goes into Sink, Source and Sink establishment time and cost are taken intoaccount can affect the networks that can be exchanged from the Source to the Sink.


2013 ◽  
Vol 367 ◽  
pp. 541-543
Author(s):  
Yun Peng Li

This article focuses on research and implementation of a kind of solid storage system that is based on NAND flash which can store the data with high speed and huge capacity. A design with quad 1.25Gsps ADC and flash storage array with 1TB is demonstrated in the paper. The design is applied widely in many fields such as radar, communication and speech recognition. The detail of hardware development is also introduced in the thesis. In addition, a method is discussed to approve the reading and writing bandwidth by parallel operations on multiple pieces of flash. By using the method, the data bandwidth is arrived 6GB/S.


2014 ◽  
Vol 1070-1072 ◽  
pp. 24-29
Author(s):  
Xiao Di Qin ◽  
Rong Rong Zhou ◽  
Lie Xia ◽  
Liang Hui Xu

Based on practical project and application, the design scheme of small capacity of integrated PV and storage grid-connected generation system is presented in this paper. For demonstrative and experimental purpose in this project, it includes several typical PV modules, tracking system and grid-connected inverters. Entire design scheme covers system integration, grid-connected solution, PV array and bracket, monitoring system, energy storage system, and etc. Configuration and application prospect of energy storage system in grid-connected PV system are mainly introduced. The characteristics of lithium battery and vanadium redox flow battery, as well as their application in the field of distributed power generation are researched.


1985 ◽  
Vol 107 (3) ◽  
pp. 569-573 ◽  
Author(s):  
C. M. Harman ◽  
S. Loesch

A method for increasing the peak output of steam power plants through use of a low-pressure feedwater storage system is presented. The generalized availability analysis involves only the low-pressure turbine, low-pressure feedwater heaters, and the storage system. With daily cycling and storage charging at near base load conditions, the turnaround efficiency of the energy storage system was found to approach 100 percent. Storage system turnaround efficiency is decreased when the energy is stored during plant part-load operation.


2015 ◽  
Vol 713-715 ◽  
pp. 1448-1451
Author(s):  
Lin Lu ◽  
Yan Feng Zhang ◽  
Xiao Feng Li

The high-altitude missile and other special application occasions have requirements on image storage system, such as small size, high storage speed, low temperature resistance, etc. Commonly used image storage system in the market cannot meet such requirement. In the paper, real-time image storage system solutions on missile based on FPGA should be proposed. The system mainly consists of acquisition module and memory reading module. The whole system adopts FPGA as main control chip for mainly completing real-time decoding and acquisition on one path of PAL format video images, reading and writing of NandFlash chipset, erasure, bad block management and so on. The solution has passed various environmental tests with stable performance, large data storage capacity and easy expansion, which has been used in engineering practice.


Sign in / Sign up

Export Citation Format

Share Document