scholarly journals Difference in glenoid retroversion between two-dimensional axial computed tomography and three-dimensional reconstructed images

2020 ◽  
Vol 23 (2) ◽  
pp. 71-79
Author(s):  
Hyungsuk Kim ◽  
Chang Hyun Yoo ◽  
Soo Bin Park ◽  
Hyun Seok Song

Background: The glenoid version of the shoulder joint correlates with the stability of the glenohumeral joint and the clinical results of total shoulder arthroplasty. We sought to analyze and compare the glenoid version measured by traditional axial two-dimensional (2D) computed tomography (CT) and three-dimensional (3D) reconstructed images at different levels.Methods: A total of 30 cases, including 15 male and 15 female patients, who underwent 3D shoulder CT imaging was randomly selected and matched by sex consecutively at one hospital. The angular difference between the scapular body axis and 2D CT slice axis was measured. The glenoid version was assessed at three levels (midpoint, upper one-third, and center of the lower circle of the glenoid) using Friedman’s method in the axial plane with 2D CT images and at the same level of three different transverse planes using a 3D reconstructed image. Results: The mean difference between the scapular body axis on the 3D reconstructed image and the 2D CT slice axis was 38.4°. At the level of the midpoint of the glenoid, the measurements were 1.7° ± 4.9° on the 2D CT images and −1.8° ± 4.1° in the 3D reconstructed image. At the level of the center of the lower circle, the measurements were 2.7° ± 5.2° on the 2D CT images and −0.5° ± 4.8° in the 3D reconstructed image. A statistically significant difference was found between the 2D CT and 3D reconstructed images at all three levels. Conclusions: The glenoid version is measured differently between axial 2D CT and 3D reconstructed images at three levels. Use of 3D reconstructed imaging can provide a more accurate glenoid version profile relative to 2D CT. The glenoid version is measured differently at different levels.

2019 ◽  
Vol 12 (1) ◽  
pp. 31-37
Author(s):  
Dave R Shukla ◽  
Richard J McLaughlin ◽  
Julia Lee ◽  
Ngoc Tram V Nguyen ◽  
Joaquin Sanchez-Sotelo

Background Preoperative planning software has been developed to measure glenoid version, glenoid inclination, and humeral head subluxation on computed tomography (CT) for shoulder arthroplasty. However, most studies analyzing the effect of glenoid positioning on outcome were done prior to the introduction of planning software. Thus, measurements obtained from the software can only be extrapolated to predict failure provided they are similar to classic measurements. The purpose of this study was to compare measurements obtained using classic manual measuring techniques and measurements generated from automated image analysis software. Methods Ninety-five two-dimensional computed tomography scans of shoulders with primary glenohumeral osteoarthritis were measured for version according to Friedman method, inclination according to Maurer method, and subluxation according to Walch method. DICOM files were loaded into an image analysis software (Blueprint, Wright Medical) and the output was compared with values obtained manually using a paired sample t-test. Results Average manual measurements included 13.8° version, 13.2° inclination, and 56.2% subluxation. Average image analysis software values included 17.4° version (3.5° difference, p < 0.0001), 9.2° inclination (3.9° difference, p < 0.001), and 74.2% for subluxation (18% difference, p < 0.0001). Conclusions Glenoid version and inclination values from the software and manual measurement on two-dimensional computed tomography were relatively similar, within approximately 4°. However, subluxation measurements differed by approximately 20%.


2017 ◽  
Vol 11 (2) ◽  
pp. 79-86
Author(s):  
Jennifer Mutch ◽  
Martin Sidler ◽  
Claudia Sidler-Maier ◽  
Terry Axelrod ◽  
Diane Nam

Background Proper glenoid position in total shoulder arthroplasty (TSA) is important. However, traditional glenoid version (GV) measurements overestimate retroversion on radiographs (XR) and computed tomography (CT). The fulcrum axis (FA) uses palpable surface landmarks and may be useful as an intra-operative guide. Also, the FA has not yet been validated on XR or CT in an arthritic population. Methods Four observers measured FA and GV on the XR, CT and three-dimensional CT (3DCT) of 40 patients who underwent TSA at a single institution from 2009 to 2015. Reliability and accuracy of FA and GV were calculated for XR and CT, using 3DCT as the gold standard. Results The mean FA and GV were 7.768° and 18.910° on XR; 6.23° and 12.920° on CT; and 8.100° and 7.740° on 3DCT, respectively. FA and GV were significantly different for XR and CT ( p < 0.001) but not for 3DCT ( p = 0.725). The inter-rater reliability, intra-rater reliability and accuracy of FA were not significantly different from GV and were 0.929 to 0.948, 0.779 to 0.974 and 0.674 to 0.705, respectively. However, the absolute difference of FA was closer to the gold standard (3DCT) than GV for XR (0.330° versus 11.172°) and CT (1.871° versus 5.178°) ( p < 0.001). Conclusions FA showed comparable reliability and accuracy to GV. However, FA more accurately reflected the gold standard.


2020 ◽  
Vol 23 (3) ◽  
pp. 119-124
Author(s):  
Chang-Hyuk Choi ◽  
Hee-Chan Kim ◽  
Daewon Kang ◽  
Jun-Young Kim

Background: This study was performed to compare glenoid version and inclination measured using two-dimensional (2D) images from computed tomography (CT) scans or three-dimensional (3D) reconstructed bone models.Methods: Thirty patients who had undergone conventional CT scans were included. Two orthopedic surgeons measured glenoid version and inclination three times on 2D images from CT scans (2D measurement), and two other orthopedic surgeons performed the same measurements using 3D reconstructed bone models (3D measurement). The 3D-reconstructed bone models were acquired and measured with Mimics and 3-Matics (Materialise).Results: Mean glenoid version and inclination in 2D measurements were –1.705º and 9.08º, respectively, while those in 3D measurements were 2.635º and 7.23º. The intra-observer reliability in 2D measurements was 0.605 and 0.698, respectively, while that in 3D measurements was 0.883 and 0.892. The inter-observer reliability in 2D measurements was 0.456 and 0.374, respectively, while those in 3D measurements was 0.853 and 0.845.Conclusions: The difference between 2D and 3D measurements is not due to differences in image data but to the use of different tools. However, more consistent results were obtained in 3D measurement. Therefore, 3D measurement can be a good alternative for measuring glenoid version and inclination.


2021 ◽  
pp. 205141582110002
Author(s):  
Lorenz Berger ◽  
Aziz Gulamhusein ◽  
Eoin Hyde ◽  
Matt Gibb ◽  
Teele Kuusk ◽  
...  

Objective: Surgical planning for robotic-assisted partial nephrectomy is widely performed using two-dimensional computed tomography images. It is unclear to what extent two-dimensional images fully simulate surgical anatomy and case complexity. To overcome these limitations, software has been developed to reconstruct three-dimensional models from computed tomography data. We present the results of a feasibility study, to explore the role and practicality of virtual three-dimensional modelling (by Innersight Labs) in the context of surgical utility for preoperative and intraoperative use, as well as improving patient involvement. Methods: A prospective study was conducted on patients undergoing robotic-assisted partial nephrectomy at our high volume kidney cancer centre. Approval from a research ethics committee was obtained. Patient demographics and tumour characteristics were collected. Surgical outcome measures were recorded. The value of the three-dimensional model to the surgeon and patient was assessed using a survey. The prospective cohort was compared against a retrospective cohort and cases were individually matched using RENAL (radius, exophytic/endophytic, nearness to collecting system or sinus, anterior/posterior, location relative to polar lines) scores. Results: This study included 22 patients. Three-dimensional modelling was found to be safe for this prospective cohort and resulted in good surgical outcome measures. The mean (standard deviation) console time was 158.6 (35) min and warm ischaemia time was 17.3 (6.3) min. The median (interquartile range) estimated blood loss was 125 (50–237.5) ml. Two procedures were converted to radical nephrectomy due to the risk of positive margins during resection. The median (interquartile range) length of stay was 2 (2–3) days. No postoperative complications were noted and all patients had negative surgical margins. Patients reported improved understanding of their procedure using the three-dimensional model. Conclusion: This study shows the potential benefit of three-dimensional modelling technology with positive uptake from surgeons and patients. Benefits are improved perception of vascular anatomy and resection approach, and procedure understanding by patients. A randomised controlled trial is needed to evaluate the technology further. Level of evidence: 2b


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Jae-Young Kim ◽  
Michael D. Han ◽  
Kug Jin Jeon ◽  
Jong-Ki Huh ◽  
Kwang-Ho Park

Abstract Background The purpose of this study was to investigate the differences in configuration and dimensions of the anterior loop of the inferior alveolar nerve (ALIAN) in patients with and without mandibular asymmetry. Method Preoperative computed tomography images of patients who had undergone orthognathic surgery from January 2016 to December 2018 at a single institution were analyzed. Subjects were classified into two groups as “Asymmetry group” and “Symmetry group”. The distance from the most anterior and most inferior points of the ALIAN (IANant and IANinf) to the vertical and horizontal reference planes were measured (dAnt and dInf). The distance from IANant and IANinf to the mental foramen were also calculated (dAnt_MF and dInf_MF). The length of the mandibular body and symphysis area were measured. All measurements were analyzed using 3D analysis software. Results There were 57 total eligible subjects. In the Asymmetry group, dAnt and dAnt_MF on the non-deviated side were significantly longer than the deviated side (p < 0.001). dInf_MF on the non-deviated side was also significantly longer than the deviated side (p = 0.001). Mandibular body length was significantly longer on the non-deviated side (p < 0.001). There was no significant difference in length in the symphysis area (p = 0.623). In the Symmetry group, there was no difference between the left and right sides for all variables. Conclusion In asymmetric patients, there is a difference tendency in the ALIAN between the deviated and non-deviated sides. In patients with mandibular asymmetry, this should be considered during surgery in the anterior mandible.


2021 ◽  
Vol 17 (4) ◽  
pp. 1-16
Author(s):  
Xiaowe Xu ◽  
Jiawei Zhang ◽  
Jinglan Liu ◽  
Yukun Ding ◽  
Tianchen Wang ◽  
...  

As one of the most commonly ordered imaging tests, the computed tomography (CT) scan comes with inevitable radiation exposure that increases cancer risk to patients. However, CT image quality is directly related to radiation dose, and thus it is desirable to obtain high-quality CT images with as little dose as possible. CT image denoising tries to obtain high-dose-like high-quality CT images (domain Y ) from low dose low-quality CT images (domain X ), which can be treated as an image-to-image translation task where the goal is to learn the transform between a source domain X (noisy images) and a target domain Y (clean images). Recently, the cycle-consistent adversarial denoising network (CCADN) has achieved state-of-the-art results by enforcing cycle-consistent loss without the need of paired training data, since the paired data is hard to collect due to patients’ interests and cardiac motion. However, out of concerns on patients’ privacy and data security, protocols typically require clinics to perform medical image processing tasks including CT image denoising locally (i.e., edge denoising). Therefore, the network models need to achieve high performance under various computation resource constraints including memory and performance. Our detailed analysis of CCADN raises a number of interesting questions that point to potential ways to further improve its performance using the same or even fewer computation resources. For example, if the noise is large leading to a significant difference between domain X and domain Y , can we bridge X and Y with a intermediate domain Z such that both the denoising process between X and Z and that between Z and Y are easier to learn? As such intermediate domains lead to multiple cycles, how do we best enforce cycle- consistency? Driven by these questions, we propose a multi-cycle-consistent adversarial network (MCCAN) that builds intermediate domains and enforces both local and global cycle-consistency for edge denoising of CT images. The global cycle-consistency couples all generators together to model the whole denoising process, whereas the local cycle-consistency imposes effective supervision on the process between adjacent domains. Experiments show that both local and global cycle-consistency are important for the success of MCCAN, which outperforms CCADN in terms of denoising quality with slightly less computation resource consumption.


Author(s):  
A H A Baazil ◽  
J G G Dobbe ◽  
E van Spronsen ◽  
F A Ebbens ◽  
F G Dikkers ◽  
...  

Abstract Objective This study aimed to compare the necessary scutum defect for transmeatal visualisation of middle-ear landmarks between an endoscopic and microscopic approach. Method Human cadaveric heads were used. In group 1, middle-ear landmarks were visualised by endoscope (group 1 endoscopic approach) and subsequently by microscope (group 1 microscopic approach following endoscopy). In group 2, landmarks were visualised solely microscopically (group 2 microscopic approach). The amount of resected bone was evaluated via computed tomography scans. Results In the group 1 endoscopic approach, a median of 6.84 mm3 bone was resected. No statistically significant difference (Mann–Whitney U test, p = 0.163, U = 49.000) was found between the group 1 microscopic approach following endoscopy (median 17.84 mm3) and the group 2 microscopic approach (median 20.08 mm3), so these were combined. The difference between the group 1 endoscopic approach and the group 1 microscopic approach following endoscopy plus group 2 microscopic approach (median 18.16 mm3) was statistically significant (Mann–Whitney U test, p < 0.001, U = 18.000). Conclusion This study showed that endoscopic transmeatal visualisation of middle-ear landmarks preserves more of the bony scutum than a microscopic transmeatal approach.


2021 ◽  
Vol 25 (03) ◽  
pp. 433-440
Author(s):  
Meghan Sahr ◽  
Ek Tsoon Tan ◽  
Darryl B. Sneag

AbstractThree-dimensional (3D) magnetic resonance imaging of the spine is now clinically feasible due to technological advancements. Its advantages over two-dimensional imaging include higher in-plane spatial resolution and the ability for reformation in any plane that enables time savings in image acquisition and aids more accurate interpretation. Multispectral 3D techniques for imaging around metal are sometimes useful for evaluating anatomy adjacent to spinal fixation hardware. 3D gradient-recalled echo sequences, including ultrashort or zero time to echo sequences, can provide osseous detail similar to conventional computed tomography.


Sign in / Sign up

Export Citation Format

Share Document