scholarly journals The Antibacterial Efficacy of Biopure MTAD in Root Canal Contaminated with Enterococcus faecalis

2012 ◽  
Vol 2012 ◽  
pp. 1-5 ◽  
Author(s):  
Blerim Kamberi ◽  
Donika Bajrami ◽  
Miranda Stavileci ◽  
Shuhreta Omeragiq ◽  
Fatmir Dragidella ◽  
...  

Aim. The purpose of this in vitro study was to assess the antimicrobial efficacy of Biopure MTAD against E. faecalis in contaminated root canals. Materials and Methods. Forty-two single rooted extracted human teeth were inoculated with E. faecalis and incubated for four weeks. The samples were divided in two control and five experimental groups irrigated with 1.5% sodium hypochlorite solution (NaOCl); 3% NaOCl; BioPure MTAD; 1.5% NaOCl/17% EDTA; or 3% NaOCl/17% EDTA. After a one-week incubation, complete disinfection was confirmed by the absence of turbidity in the incubation media. Dentin shavings were taken from samples with no turbidity to verify whether E. faecalis was present in dentin tubules. Results were analyzed statistically using Fisher's exact test, with the level of significance set at . Results. Statistical analysis of the data obtained at Day 7 and after dentin shaving analysis showed that BioPure MTAD had significantly greater antibacterial activity than 1.5% NaOCl, 1.5% NaOCl/17% EDTA and 3% NaOCl/17% EDTA. No significant difference was detected between MTAD and 3% NaOCl. Conclusions. These findings suggest that BioPure MTAD possesses superior bactericidal activity compared with NaOCl and EDTA against E. faecalis.

Materials ◽  
2019 ◽  
Vol 12 (23) ◽  
pp. 4001
Author(s):  
Vincenzo D’Antò ◽  
Simone Muraglie ◽  
Beatrice Castellano ◽  
Ettore Candida ◽  
Maria Francesca Sfondrini ◽  
...  

Background: Attachments are composite auxiliaries that are used during a clear aligner orthodontic therapy to achieve difficult tooth movements. Two important factors are the planned configuration and the actual position of these auxiliary elements to obtain the desired force system. The aim of the present study was to evaluate the role of different composite materials in the correct reproduction of attachment shape and position. Methods: The materials that were considered in the study were a flowable resin, a dental restorative material, and an orthodontic composite. The attachments were created on three models of extracted teeth. Once the impressions were performed, 25 attachments of different shapes were added onto each virtual model to obtain the necessary templates to make the attachments. Each tested material was used to create a set of 25 attachments that were then scanned with an accuracy of 10μm. The resultant STL (stereolithography) files were superimposed onto the ones from the initial virtual plan, through Geomagic software, and the aligned scans were then compared while using a color map. The parameters that were calculated to make a comparison between the created attachments and the ideal ones were the maximum deviation in defect and in excess, the overflow, and the volume’s difference. In addition to these measurements comparing the three above-mentioned groups, the difference in volume between all the ideal and realized samples were analyzed. To test for differences among the three groups, a one-way Analysis of variance (ANOVA) was used with a Bonferroni post-hoc test. The level of significance was set at p < 0.05. Results: No statistically significant results were found between the three groups regarding the maximum value in defect, the maximum value in excess, and the minimum value as control, while a statistically significant difference was found between the overflow of orthodontic resin when compared to the flowable composite. Conclusions: The three materials that were used in this study were appropriate for attachment fabrication. The fidelity of attachment reproduction was similar when using the three different composites. The orthodontic composite showed more overflow when compared with the flowable one.


2016 ◽  
Vol 21 (2) ◽  
Author(s):  
Fernanda Diederichs Coutinho ◽  
Renata Dornelles Morgental ◽  
Simone Bonato Luisi ◽  
Fabiana Vieira Vier-Pelisser ◽  
Patricia Maria Poli Kopper

Objective: This study evaluated through stereomicroscopy the effectiveness of hand and rotary instrumentation techniques, either isolated or combined, in the preparation of oval-shaped root canals. Materials and method: Thirty single-rooted human mandibular incisors were selected. After endodontic access and coronal preflaring, teeth were mounted in a modified Bramante muffle and then sectioned transversely at 3 and 6 mm from the root apex. Images of each section were made under a stereomicroscope at 30× magnification. Teeth were reassembled in the muffle and divided into three groups (n=10) according to the root canal preparation technique: GI - rotary preparation with Mtwo™ basic sequence (10/.04; 15/.05; 20/.06; 25/.06), followed by Mtwo™ complementary instruments (30/.05; 35/.04; 40/.04); GII - rotary preparation with Mtwo™ basic sequence, complemented by hand instruments (#30, #35 and #40); GIII - hand instrumentation using the conventional technique (#10 to #40). All instruments were used in brushing motion. The muffles were separated again so that new images of each section could be obtained. The following parameters were evaluated in pre- and postoperative images: root canal area; perimeter; mesiodistal (MD) and buccolingual (BL) diameters; and mesial (M) and distal (D) wall thickness. Next, the values measured in post- and preoperative images were subtracted forcomparison of experimental groups. Data were analyzed using the Kruskal-Wallis test (α=0.05). Results: No significant difference between groups was observed for all parameters. Conclusion: There was no difference among hand, rotary, or combined instrumentation; all techniques were able to increase root canal area, perimeter, and diameter in MD and BL directions. Moreover, the amount of dentin wearon proximal root canal walls was similar for all tested groups.


2016 ◽  
Vol 2016 ◽  
pp. 1-5 ◽  
Author(s):  
A. Namour ◽  
S. Geerts ◽  
T. Zeinoun ◽  
R. De Moor ◽  
S. Nammour

Objective. Nd:YAP laser has several potentialities of clinical applications in endodontics. The aim of our study is to determine the safety range of irradiation parameters during endodontic application of Nd:YAP laser that can be used without damaging and overheating the periodontal tissue.Material and Methods. Twenty-seven caries-free single-rooted extracted human teeth were used. Crowns were sectioned to obtain 11 mm root canal length. Temperature increases at root surfaces were measured by a thermocouple during Nd:YAP laser irradiation of root canals at different energy densities. Canal irradiation was accomplished with a circular and retrograde movement from the apex until the cervical part of the canal during 10 seconds with an axial speed of 1 mm/s. Each irradiation was done in a canal irrigated continuously with 2.25% NaOCl solution.Results. Periodontal temperature increase depends on the value of energy density. Means and standard deviations of temperature increases at root surfaces were below 10°C (safe threshold level) when the average energy densities delivered per second were equal to or below 4981 J/cm2and 9554 J/cm2, respectively, for irradiations using a fiber diameter of 320 μm and 200 μm.Conclusions. Within the limitations of this study and under specific irradiation conditions, Nd:YAP laser beam may be considered harmless for periodontal tissues during endodontic applications.


2021 ◽  
Vol 58 (1) ◽  
pp. eUJ3657
Author(s):  
Germano Brandão ◽  
◽  
Liliana Ávila Maltagliati ◽  
Ana Carla Raphaelli Nahás-Scocate ◽  
Murilo Matias ◽  
...  

The objective of this in vitro study was to assess and compare the shear bond strength of conventional and modified orthodontic tubes bonded to the surface of dry and saliva-contaminated enamel. The sample consisted of 40 human teeth, which were randomly divided into four groups according to attachment base and presence or absence of saliva contamination as follows: Group CB, conventional orthodontic tubes without salivary contamination; Group CB-S, conventional orthodontic tubes with salivary contamination; Groups BM, orthodontic tubes modified by welding a metal mesh to their base without salivary contamination; and Group BM-S, modified orthodontic tubes with salivary contamination. Shear bond strength test was performed in a universal testing machine and analysis of the adhesive remnant index (ARI) by optical microscopy. Two-way ANOVA was used, followed by Tukey’s test at a statistical significance level of 5%. The ARI results were analysed descriptively. There was statistically significant difference between the groups regarding the shear bond strength values, with conventional tubes presenting significantly higher values (P < 0.05). In addition, the presence of salivary contamination interfered negatively with the behaviour of conventional tubes only (P < 0.05). Shear bond strength was not improved by increasing the area of the orthodontic tubes. Moreover, salivary contamination influenced negatively the SBS values, but only when conventional tubes were used.


2006 ◽  
Vol 20 (3) ◽  
pp. 231-234 ◽  
Author(s):  
Eliana Barbosa de Souza ◽  
Crystiane Venditti Gomes de Amorim ◽  
José Luiz Lage Marques

Apical sealing is essential for the success of paraendodontic surgery, so any procedure that may favor an adequate sealing of the apical remainder should be performed. The purpose of this study was to evaluate the influence of diode laser irradiation on the apical sealing of root-end cavities with MTA retrofillings. Root canals in twenty extracted human teeth were shaped with K-files and filled with gutta-percha. The apexes were cut off and root-end preparations were performed. The roots were divided randomly in 2 groups. Group 1 (ten specimens) was retrofilled with MTA. Group 2 was irradiated with diode laser, with 1 W for 20 seconds, on the apical surface and root end cavity before retrofilling with MTA. The specimens had their external surfaces impermeabilized with cyanoacrylate, except for the apical surface, and were then immersed in 1% rhodamine B dye for 72 h and placed in plaster stone. After that, the specimens were submitted to longitudinal abrasion until half of the root remained. The linear dye leakage was observed in these mid-roots between the root canal wall and retrofilling. The linear dye leakage was measured with Image Lab software, and the results were statistically analyzed with Student's t test. There were no statistically significant differences between the two groups (p > 0.05). The diode laser irradiation did not improve the apical sealing of MTA retrofillings under the conditions of this in vitro study.


1995 ◽  
Vol 31 (3) ◽  
pp. 250-253 ◽  
Author(s):  
N White-Weithers ◽  
L Medleau

Seven commonly used, topical antifungal products (i.e., lime sulfur, chlorhexidine, captan, povidone-iodine, sodium hypochlorite, and enilconazole solutions, and ketoconazole shampoo) were evaluated for their antifungal activity on Microsporum canis-infected hairs from dogs and cats in an in vitro study. Hairs were soaked or shampooed in each product for five minutes twice a week for four weeks. Of the seven products used in this study, lime sulfur and enilconazole solutions were superior in inhibiting fungal growth; no growth occurred on fungal cultures after two treatments with either product. Chlorhexidine and povidone iodine solutions were effective after four treatments, and sodium hypochlorite solution and ketoconazole shampoo inhibited fungal growth after eight treatments. Captan did not inhibit fungal growth during the test period.


2015 ◽  
Vol 03 (03) ◽  
pp. 152-158
Author(s):  
Varun Jindal ◽  
Ajay Chhabra ◽  
◽  

Abstract Objectives: The study aimed to assess variation in the remaining filling material by radiographic analysis and the time taken for retreatment system, with H-files; the ProTaper Universal Retreatment System; Mtwo retreatment system and the SybronEndo K3. Methods: 120 human mandibular premolars with single straight root canals were prepared with rotary twisted files (up to size 40/0.04) using the crown down technique and filled by cold lateral condensation and the radiographs were taken. After one week, teeth were divided into four groups (n = 30). Gutta-percha was removed using H-files, the ProTaper Universal Retreatment System, Mtwo system and the K3 System. After retreatment radiographs were taken for each sample and the remaining material was calculated for each canal third. Results: Rotary NiTi instruments were significantly faster than the hand instrumentation technique in performing the retreatment. In radiographic analysis there was significant difference in between the groups for coronal third in ProTaper group and for apical third in H-file group. Conclusions: In the radiographic analysis the ProTaper Universal System left less filling material in the coronal third and the H-files left less filling material in apical third as compared to other groups. Rotary instruments worked faster than H files.


Sign in / Sign up

Export Citation Format

Share Document