scholarly journals Health effects from exposure to dental diagnostic X-ray

2018 ◽  
Vol 33 (4) ◽  
pp. e2018017 ◽  
Author(s):  
Su-Yeon Hwang ◽  
Eun-Sil Choi ◽  
Young-Sun Kim ◽  
Bo-Eun Gim ◽  
Mina Ha ◽  
...  
Keyword(s):  
2014 ◽  
Vol 34 (4) ◽  
pp. 345-356 ◽  
Author(s):  
H Kitamura ◽  
N Terunuma ◽  
S Kurosaki ◽  
K Hata ◽  
M Masuda ◽  
...  

Objectives: This study uses pulmonary function tests and chest x-ray examinations to examine the relationship between toner-handling work and its health effects. Methods: The subjects were 1504 male workers in a Japanese toner and photocopier manufacturing company, in the age range from 19 to 50 years in 2003. Personal exposure measurements, pulmonary function tests, chest x-ray examinations, biomarker measurements, and a questionnaire about respiratory symptoms were conducted. The present study reports the results of pulmonary function tests and chest x-ray examinations conducted in the subjects, which includes a cross-sectional study on the toner handling and non-handling workers and a longitudinal study from 2003 to 2008. Results: Few significant findings were suspected to be caused by toner exposure found in pulmonary function indices in both the cross-sectional and longitudinal studies. Any obvious fibrotic findings in chest x-ray findings related to the toner exposure could not be found out. Conclusion: No evidence of adverse effects on pulmonary function indices and chest x-rays was present in the toner-handling workers as compared to the nonspecifically exposed workers. Although the toner exposure concentration is quite low in the current well-controlled working environment, even among the toner-handling workers, we would like to continue this study in the future to verify the toner exposure health effects.


2014 ◽  
Vol 2014 ◽  
pp. 1-10 ◽  
Author(s):  
Hiroko Kitamura ◽  
Niina Terunuma ◽  
Shizuka Kurosaki ◽  
Koichi Hata ◽  
Masashi Masuda ◽  
...  

This study examines the relationship between toner-handling work and its health effects on self-reported respiratory symptoms. The subjects were 1,504 male workers in a Japanese toner and photocopier manufacturing company. Personal exposure measurement, pulmonary function tests, chest X-ray examination, measurement of biomarkers, and a questionnaire about self-reported respiratory symptoms were performed annually. This study discusses the questionnaire results. We found that the toner-handling group showed significantly higher prevalence of breathlessness than the never-toner-handling group. The significant reduction of pulmonary function and fibrosis change in the chest X-ray examination associated with breathlessness were not observed. However the morbidity of asthma was higher compared to the Japanese population in both of the toner-handling group and the never-toner handling group, the effect of toner exposure was not clarified. Nevertheless, while the toner exposure levels in the current well-controlled working environment may be sufficiently low to prevent adverse health effects, further studies are needed to assess the more long-term latent health effects of toner exposure.


2012 ◽  
Vol 41 (3-4) ◽  
pp. 129-141 ◽  
Author(s):  
M.I. Balonov ◽  
P.C. Shrimpton

The radiation risks from a range of medical x-ray examinations (radiography, fluoroscopy, and computed tomography) were assessed as a function of the age and sex of the patient using risk models described in Publication 103 (ICRP, 2007) and UNSCEAR (2006, Annex A). Such estimates of risk based on typical organ doses were compared with those derived from effective doses using the International Commission on Radiological Protection's nominal risk coefficients. Methodologically similar but not identical dose and risk calculations were performed independently at the Institute of Radiation Hygiene (Russia) and the Health Protection Agency (UK), and led to similar conclusions. The radiogenic risk of stochastic health effects following various x-ray procedures varied significantly with the patient's age and sex, but to differing degrees depending on which body organs were irradiated. In general, the risks of radiation-induced stochastic health effects in children are estimated to be higher (by a factor of ⩽4) than in adults, and risks in senior patients are lower by a factor of ⩾10 relative to younger people. If risks are assessed on the basis of effective dose, they are underestimated for children of both sexes by a factor of ⩽4. This approach overestimates risks by a factor of ⩽3 for adults and about an order of magnitude for senior patients. The significant sex and age dependence of radiogenic risk for different cancer types is an important consideration for radiologists when planning x-ray examinations. Whereas effective dose was not intended to provide a measure of risk associated with such examinations, it may be sufficient to make simple adjustments to the nominal risk per unit effective dose to account for age and sex differences.


2014 ◽  
Vol 2014 ◽  
pp. 1-9 ◽  
Author(s):  
Aaron James Specht ◽  
Marc Weisskopf ◽  
Linda Huiling Nie

Lead is a ubiquitous toxicant. Bone lead has been established as an important biomarker for cumulative lead exposures and has been correlated with adverse health effects on many systems in the body. K-shell X-ray fluorescence (KXRF) is the standard method for measuring bone lead, but this approach has many difficulties that have limited the widespread use of this exposure assessment method. With recent advancements in X-ray fluorescence (XRF) technology, we have developed a portable system that can quantify lead in bone in vivo within 3 minutes. Our study investigated improvements to the system, four calibration methods, and system validation for in vivo measurements. Our main results show that the detection limit of the system is 2.9 ppm with 2 mm soft tissue thickness, the best calibration method for in vivo measurement is background subtraction, and there is strong correlation between KXRF and portable LXRF bone lead results. Our results indicate that the technology is ready to be used in large human population studies to investigate adverse health effects of lead exposure. The portability of the system and fast measurement time should allow for this technology to greatly advance the research on lead exposure and public/environmental health.


1994 ◽  
Vol 144 ◽  
pp. 275-277
Author(s):  
M. Karlický ◽  
J. C. Hénoux

AbstractUsing a new ID hybrid model of the electron bombardment in flare loops, we study not only the evolution of densities, plasma velocities and temperatures in the loop, but also the temporal and spatial evolution of hard X-ray emission. In the present paper a continuous bombardment by electrons isotropically accelerated at the top of flare loop with a power-law injection distribution function is considered. The computations include the effects of the return-current that reduces significantly the depth of the chromospheric layer which is evaporated. The present modelling is made with superthermal electron parameters corresponding to the classical resistivity regime for an input energy flux of superthermal electrons of 109erg cm−2s−1. It was found that due to the electron bombardment the two chromospheric evaporation waves are generated at both feet of the loop and they propagate up to the top, where they collide and cause temporary density and hard X-ray enhancements.


1994 ◽  
Vol 144 ◽  
pp. 1-9
Author(s):  
A. H. Gabriel

The development of the physics of the solar atmosphere during the last 50 years has been greatly influenced by the increasing capability of observations made from space. Access to images and spectra of the hotter plasma in the UV, XUV and X-ray regions provided a major advance over the few coronal forbidden lines seen in the visible and enabled the cooler chromospheric and photospheric plasma to be seen in its proper perspective, as part of a total system. In this way space observations have stimulated new and important advances, not only in space but also in ground-based observations and theoretical modelling, so that today we find a well-balanced harmony between the three techniques.


1994 ◽  
Vol 144 ◽  
pp. 82
Author(s):  
E. Hildner

AbstractOver the last twenty years, orbiting coronagraphs have vastly increased the amount of observational material for the whitelight corona. Spanning almost two solar cycles, and augmented by ground-based K-coronameter, emission-line, and eclipse observations, these data allow us to assess,inter alia: the typical and atypical behavior of the corona; how the corona evolves on time scales from minutes to a decade; and (in some respects) the relation between photospheric, coronal, and interplanetary features. This talk will review recent results on these three topics. A remark or two will attempt to relate the whitelight corona between 1.5 and 6 R⊙to the corona seen at lower altitudes in soft X-rays (e.g., with Yohkoh). The whitelight emission depends only on integrated electron density independent of temperature, whereas the soft X-ray emission depends upon the integral of electron density squared times a temperature function. The properties of coronal mass ejections (CMEs) will be reviewed briefly and their relationships to other solar and interplanetary phenomena will be noted.


1988 ◽  
Vol 102 ◽  
pp. 47-50
Author(s):  
K. Masai ◽  
S. Hayakawa ◽  
F. Nagase

AbstractEmission mechanisms of the iron Kα-lines in X-ray binaries are discussed in relation with the characteristic temperature Txof continuum radiation thereof. The 6.7 keV line is ascribed to radiative recombination followed by cascades in a corona of ∼ 100 eV formed above the accretion disk. This mechanism is attained for Tx≲ 10 keV as observed for low mass X-ray binaries. The 6.4 keV line observed for binary X-ray pulsars with Tx> 10 keV is likely due to fluorescence outside the He II ionization front.


1988 ◽  
Vol 102 ◽  
pp. 357-360
Author(s):  
J.C. Gauthier ◽  
J.P. Geindre ◽  
P. Monier ◽  
C. Chenais-Popovics ◽  
N. Tragin ◽  
...  

AbstractIn order to achieve a nickel-like X ray laser scheme we need a tool to determine the parameters which characterise the high-Z plasma. The aim of this work is to study gold laser plasmas and to compare experimental results to a collisional-radiative model which describes nickel-like ions. The electronic temperature and density are measured by the emission of an aluminium tracer. They are compared to the predictions of the nickel-like model for pure gold. The results show that the density and temperature can be estimated in a pure gold plasma.


Sign in / Sign up